Home › General › SPECIFICATIONS › 3UR-FE CHARGING
RM27M0U _V1 General _049092 SPECIFICATIONS _0233854 3UR-FE CHARGING F

SPECIFICATIONS  3UR-FE CHARGING  SERVICE DATA  


Battery Standard specific gravity 1.25 to 1.29 at 20°C (68°F)
Charging circuit without load Standard amperage 10 A or less
Standard voltage 13.2 to 14.8 V
(when engine speed at 2000 rpm)
Charging circuit with load Standard amperage 30 A or more
Generator rotor Standard resistance between the slip rings
100 A Type and 130 A Type
2.3 to 2.7 Ω at 20°C (68°F)
between the slip rings
150 A Type
1.5 to 1.9 Ω at 20°C (68°F)
between the slip ring and rotor 10 kΩ or higher
Standard diameter 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter 14.0 mm (0.551 in.)
Generator brush holder Standard exposed length 10.5 mm (0.413 in.)
Minimum exposed length 4.5 mm (0.177 in.)