Home › General › SPECIFICATIONS › 3UR-FBE ENGINE CONTROL
RM27M0U _V1 General _049092 SPECIFICATIONS _0233872 3UR-FBE ENGINE CONTROL F

SPECIFICATIONS  3UR-FBE ENGINE CONTROL  SERVICE DATA  


MAF meter:
Tester Connection Condition Specified Condition
4 (THA) - 2 (E2G) -20°C (-4°F) 12.5 k to 16.9 kΩ
20°C (68°F) 2.19 k to 2.67 kΩ
60°C (140°F) 0.50 k to 0.68 kΩ


Camshaft timing oil control valve:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 6.9 to 7.9 Ω


Engine coolant temperature sensor:
Tester Connection Condition Specified Condition
1 - 2 Approx. 20°C (68°F) 2.32 k to 2.59 kΩ
Approx. 80°C (176°F) 0.310 k to 0.326 kΩ


Throttle body:
Tester Connection Condition Specified Condition
1 (M-) - 2 (M+) 20°C (68°F) 0.3 to 100 Ω


Knock sensor:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 120 to 280 kΩ


Ignition relay No. 2:
Tester Connection Condition Specified Condition
IG2 MAIN fuse Always Below 1 Ω
1C-1 - 1B-8 When battery voltage is not applied to terminals 1B-6 and 1B-7 10 kΩ or higher
When battery voltage is applied to terminals 1B- 6 and 1B-7 Below 1 Ω


EFI relay:
Tester Connection Condition Specified Condition
EFI No. 1 fuse Always Below 1 Ω
1C-1 - 1B-4
1C-1 - 1B-5
When battery voltage is not applied to terminals 1B-2 and 1B-3) 10 kΩ or higher
When battery voltage is applied to terminals 1B- 2 and 1B-3) Below 1 Ω


Circuit opening relay:
Tester Connection Condition Specified Condition
3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
When battery voltage is applied to terminals 1 and 2 Below 1 Ω


Fuel pump relay:
Tester Connection Condition Specified Condition
3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
When battery voltage is applied to terminals 1 and 2 Below 1 Ω


Fuel pressure control valve relay:
Tester Connection Condition Specified Condition
3 - 5 When battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
When battery voltage is applied to terminals 1 and 2 Below 1 Ω


Air fuel ration sensor (for Bank 1 sensor 1):
Tester Connection Condition Specified Condition
1 (HA1A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω


Air fuel ration sensor (for Bank 2 sensor 1):
Tester Connection Condition Specified Condition
1 (HA2A) - 2 (+B) 20°C (68°F) 1.6 to 3.2 Ω


Heated oxygen sensor (for Bank 1 sensor 2):
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 11 to 16 Ω


Heated oxygen sensor (for Bank 2 sensor 2):
Tester Connection Condition Specified Condition
1 (HT2B) - 2 (+B) 20°C (68°F) 11 to 16 Ω


A/F sensor heater relay:
Tester Connection Condition Specified Condition
A/F fuse Always Below 1 Ω
1C-1 - 1A-4 When battery voltage is not applied to terminals 1A-2 and 1A-3 10 kΩ or higher
When battery voltage is applied to terminals 1A- 2 and 1A-3 Below 1 Ω