Home › General › SPECIFICATIONS › 1UR-FE EMISSION CONTROL
RM27M0U _V1 General _049092 SPECIFICATIONS _0233873 1UR-FE EMISSION CONTROL F

SPECIFICATIONS  1UR-FE EMISSION CONTROL  SERVICE DATA  


EGR VALVE:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 18 to 22 Ω
2 - 3
4 - 5
5 - 6


AIR PUMP (Standard Current):
Condition Specified Condition
20°C (68°F) 10 to 40 A


AIR PUMP (Standard Resistance):
Tester Connection Condition Specified Condition
1 (APH+) - 3 (APHG) -20°C (-4°F) 4.4 to 20.0 Ω
-10°C (14°F) 3.9 to 18.0 Ω
0°C (32°F) 3.5 to 16.0 Ω
10°C (50°F) 3.2 to 15.0 Ω
20°C (68°F) 3.0 to 14.0 Ω


AIR SWITCHING VALVE (for Bank 1):
Tester Connection Condition Specified Condition
1 - 5 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground Always 1 MΩ or higher
5 - Body ground


AIR SWITCHING VALVE (for Bank 2):
Tester Connection Condition Specified Condition
1 - 5 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground Always 1 MΩ or higher
5 - Body ground


PURGE VALVE:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 23 to 26 Ω
1 - VSV body ground Always 10 MΩ or higher
2 - VSV body ground 10 MΩ or higher