RM27M0U
_V1
General
_049092
SPECIFICATIONS
_0233877
1UR-FE INTAKE
F
SPECIFICATIONS 1UR-FE INTAKE SERVICE DATA
VACUUM SWITCHING VALVE (for ACIS)
| Tester Connection
|
Condition
|
Specified Condition
|
| 1-2
|
20°C (68°F)
|
37 to 44 Ω
|
1-Body ground
2-Body ground
|
Always
|
1 MΩ or higher
|