Home › Engine / Hybrid System › 3UR-FE ENGINE CONTROL › SFI SYSTEM
RM27M0U _51 Engine / Hybrid System _049094 3UR-FE ENGINE CONTROL _0233910 SFI SYSTEM C

3UR-FE ENGINE CONTROL  SFI SYSTEM  P043E  Evaporative Emission System Leak Detection Reference Orifice Low Flow  P043F  Evaporative Emission System Reference Orifice High Flow  P2401  Evaporative Emission Leak Detection Pump Stuck OFF  P2402  Evaporative Emission Leak Detection Pump Stuck ON  P2419  Evaporative Emission System Switching Valve Control Circuit Low  


DTC SUMMARY

DTC Code Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic
P043E Reference orifice clogged P043E, P043F, P2401, P2402 and P2419 present when one of following conditions met during key-off EVAP monitor:
·

Reference orifice clogged

·

Reference orifice high-flow

·

Leak detection pump OFF malfunction

·

Leak detection pump ON malfunction

·

Vent valve ON (close) malfunction


·

Canister pump module (Reference orifice, leak detection pump, vent valve)

·

Connector/wire harness (Canister pump module - ECM)

·

EVAP system hose (pipe from air inlet port to canister pump module, canister filter, fuel tank vent hose)

·

ECM


While ignition switch off 2 trip
P043F Reference orifice high-flow
P2401 Leak detection pump stuck OFF
P2402 Leak detection pump stuck ON
P2419 Vent valve stuck closed

HINT:

The reference orifice is located inside the canister pump module.


DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System (See page Engine / Hybrid System>3UR-FE ENGINE CONTROL>SFI SYSTEM>EVAP System).

CAUTION / NOTICE / HINT

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa-a and 110 kPa-a (525 mmHg-a and 825 mmHg-a), ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
·

360 seconds*1

·

300 seconds*2


C EVAP system pressure measurement Vent valve turned ON (closed) to shut EVAP system.
Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.
Write down measured value as it will be used in leak check.
If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
·

15 minutes*1*3

·

30 minutes*2, *3


D Purge VSV monitor Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normality.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
- Final check Atmospheric pressure measured and then monitoring result recorded by ECM. -

*1: for 100 L (26.4 US gal) Fuel Tank

*2: for 144 L (38 US gal) Fuel Tank

*3: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.

A112612E64
1.115,0.51 1.219,0.927 false 1.625,2.188 2,2.396 false 2.458,1.146 2.823,1.083 false 1.813,1.583 2.792,1.375 true 2.417,1.656 2.802,1.635 false 2.583,2.063 2.854,2.063 false 1.219,3.313 1.219,3.438 false 1.271,4.49 1.552,4.51 false 2.313,3.188 1.844,3.948 true 5.083,0.958 5.083,1.083 false 5.667,1.583 6.302,1.292 true 5.292,2.188 5.417,2.146 false 5.76,3.948 6.323,3.615 true 5.188,4.49 5.438,4.5 false 5.094,3.302 5.094,3.438 false 1.594,1.083 1.688,0.677 false 0.646,2.167 1.448,1.948 false 5.01,1.719 4.719,2.344 true 0.104,0.104 3.542,0.292 3.438,0.188 10 false Operation A: Atmospheric Pressure Measurement 0.344,2.75 3.708,2.938 3.365,0.188 10 false Operation C: EVAP System Pressure Measurement 4.469,0.042 5.615,0.229 1.146,0.188 10 false Operation B, E: 4.479,0.333 7.01,0.521 2.531,0.188 10 false Reference Pressure Measurement 4.552,2.698 7,2.917 2.448,0.219 10 false Operation D: Purge VSV Monitor 0.052,0.417 1.208,0.625 1.156,0.208 10 false Purge VSV: OFF 1.729,0.563 2.26,0.74 0.531,0.177 10 false Canister 2.854,0.938 3.49,1.115 0.635,0.177 10 false Fuel Tank 2.854,1.271 4.292,1.448 1.438,0.177 10 false Vent Valve: OFF (vent) 2.854,1.573 4.542,1.792 1.688,0.219 10 false Canister Pump Module 2.917,1.979 3.823,2.156 0.906,0.177 10 false Canister Filter 0.042,1.938 0.646,2.5 0.604,0.563 10 false Canister Pressure Sensor 1.573,2.396 3.354,2.573 1.781,0.177 10 false Leak Detection Pump: OFF 1.073,3.458 1.417,3.635 0.344,0.177 10 false OFF 1.042,4.396 1.323,4.583 0.281,0.188 10 false ON 2.354,3.083 3.115,3.26 0.76,0.177 10 false ON (closed) 3.385,3.521 4.198,3.885 0.813,0.365 10 false Atmospheric Pressure 3.385,4.031 4.063,4.396 0.677,0.365 10 false Negative Pressure 4.927,1.104 5.25,1.281 0.323,0.177 10 false OFF 6.365,1.188 7.083,1.385 0.719,0.198 10 false OFF (vent) 5.021,2.094 5.281,2.271 0.26,0.177 10 false ON 4.104,2.375 6.354,2.563 2.25,0.188 10 false Reference Orifice (0.02 Inch) 5.01,3.458 5.281,3.646 0.271,0.188 10 false ON 4.906,4.396 5.156,4.573 0.25,0.177 10 false ON 6.344,3.563 7.146,3.771 0.802,0.208 10 false ON (closed)

The leak detection pump creates negative pressure through the reference orifice. When the system is normal, the EVAP pressure is between 724 to 752 mmHg* and saturated within a minute. If not, the ECM interprets this as a malfunction. The ECM will illuminate the MIL and set a DTC if this malfunction is detected in consecutive drive cycles.

*: Typical value.

A358302E06
0.125,0.052 3.042,0.26 2.917,0.208 10 false EVAP Pressure during EVAP key-off monitor 0.365,0.5 1.135,0.688 0.771,0.188 10 false Purge VSV 0.396,1.052 1.135,1.24 0.74,0.188 10 false Vent Valve 0.156,1.417 1.135,1.802 0.979,0.385 10 false Leak Detection Pump 0.073,2.083 1.135,2.292 1.063,0.208 10 false EVAP Pressure 0.323,2.396 1.094,2.604 0.771,0.208 10 false 760 mmHg 0.333,2.75 1.135,2.958 0.802,0.208 10 false 752 mmHg 0.323,3.771 1.073,3.969 0.75,0.198 10 false 724 mmHg 0.427,4.042 1.135,4.24 0.708,0.198 10 false Sequence 0.083,4.323 1.125,4.563 1.042,0.24 10 false Time (Seconds) 1.604,4.313 1.865,4.51 0.26,0.198 10 false 60 1.635,4.052 1.813,4.229 0.177,0.177 10 false A 2.521,4.063 2.698,4.24 0.177,0.177 10 false B 2.385,4.281 2.854,4.479 0.469,0.198 10 false 360*1 3.844,4.063 4.021,4.24 0.177,0.177 10 false C 3.365,4.292 4.698,4.479 1.333,0.188 10 false Within 15 minutes*1 5.094,4.052 5.271,4.229 0.177,0.177 10 false D 5.073,4.292 5.333,4.49 0.26,0.198 10 false 10 5.667,4.042 5.844,4.219 0.177,0.177 10 false E 5.635,4.302 5.896,4.5 0.26,0.198 10 false 60 3.76,2.969 4.719,3.167 0.958,0.198 10 false : Malfunction 3.75,2.646 4.24,2.833 0.49,0.188 10 false : OK 3.813,1.5 4.083,1.688 0.271,0.188 10 false ON 3.865,1 4.135,1.188 0.271,0.188 10 false ON 5.042,0.448 5.313,0.635 0.271,0.188 10 false ON 6.292,1.135 7.104,1.323 0.813,0.188 10 false OFF: Vent 6.281,0.583 7.146,0.76 0.865,0.177 10 false OFF: Closed 6.271,0.865 7.083,1.052 0.813,0.188 10 false ON: Closed 6.281,0.302 7.021,0.49 0.74,0.188 10 false ON: Open 2.385,4.438 2.865,4.583 0.479,0.146 10 true 300*2 3.365,4.531 4.698,4.719 1.333,0.188 10 false Within 30 minutes*2

*1: for 100 L (26.4 US gal) Fuel Tank

*2: for 144 L (38 US gal) Fuel Tank

MONITOR STRATEGY

Required Sensors/Components Canister pump module
Frequency of Operation Once per driving cycle
Duration Within 7 minutes
MIL Operation 2 driving cycles
Sequence of Operation None

TYPICAL ENABLING CONDITIONS

Monitor runs whenever following DTCs not present P0452, P0453 (EVAP System)
EVAP key-off monitor runs when all of following conditions met -
Atmospheric pressure 70 to 111 kPa (525 to 833 mmHg)
Battery voltage 10.5 V or more
Vehicle speed Below 4 km/h (2.5 mph)
Ignition switch Off
Time after key off 5 or 7 or 9.5 hours
Canister pressure sensor malfunction (P0452, P0453) Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of following conditions met before key off Conditions 1 and 2
1. Duration that vehicle driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)

TYPICAL MALFUNCTION THRESHOLDS

"Saturated" indicates that the EVAP pressure change is less than 0.286 kPa (2.14 mmHg) in 60 seconds.

One of following conditions met -
EVAP pressure just after reference pressure measurement started More than -1 kPa (-7.5 mmHg)
Reference pressure Less than -4.85 kPa (-36.4 mmHg)
Reference pressure -1.057 kPa (-7.93 mmHg) or more
Reference pressure
·

Not saturated within 360 seconds (for 100 L (26.4 US gal) Fuel Tank)

·

Not saturated within 300 seconds (for 144 L (38 US gal) Fuel Tank)


Reference pressure difference between first and second 0.9 kPa (6.75 mmHg) or more

CONFIRMATION DRIVING PATTERN

A199236E49
0.079,1.247 1.360,1.500 1.281,0.253 10 Ignition Switch ON 3.455,2.359 5.083,2.536 1.628,0.177 10 Approximately 24 minutes 2.76,2.91 2.971,3.131 0.211,0.221 10 [A] 5.398,2.923 5.631,3.116 0.233,0.193 10 [B]

NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by Techstream. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or more, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).



1.

Connect the Techstream to the DLC3.

2.

Turn the ignition switch to ON and turn the Techstream on.

3.

Clear DTCs (even if no DTCs are stored, perform the clear DTC operation).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the Techstream on [A].

6.

Enter the following menu items: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

7.

After the Evaporative System Check is completed, check for All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All readiness.

8.

Input the DTC: P043E, P043F, P2401, P2402 or P2419.

9.

Check the DTC judgment result [B].

Tester Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU's memory limit



HINT:

If the judgment result shows ABNORMAL, the system has a malfunction.


10.

If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (See page Engine / Hybrid System>3UR-FE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).

HINT:
·

If a permanent DTC is output, the system is malfunctioning.

·

If no permanent DTC is output, the system is normal.




MONITOR RESULT

PROCEDURE

1.GO TO EVAP SYSTEM

NEXT

END