Home › Engine / Hybrid System › 3UR-FE ENGINE CONTROL › ECM
RM27M0U _51 Engine / Hybrid System _049094 3UR-FE ENGINE CONTROL _0233921 ECM A

3UR-FE ENGINE CONTROL  ECM  INSTALLATION  


PROCEDURE

Hide 1.INSTALL GASKET

a.

Clean the ECM seal's surface with non-residue solvent.


b.

Attach a new gasket to the ECM.


Hide 89661 2.INSTALL ECM

a.
A155993

Install the ECM with the 4 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)

NOTICE:
·

Make sure the gasket is not folded or caught on any area on the surrounding part.

·

Make sure there is no foreign matter caught between the gasket and surrounding part.

·

Do not damage the gasket.




b.
A160064

Connect the 2 ECM connectors and push each lock lever down to lock the ECM connectors.

NOTICE:
·

Make sure that the lock lever is raised 90° before connecting the ECM connectors. Failure to do this may cause the lock lever and terminals to break.

·

Do not twist the wire harness when connecting the ECM connectors.




Hide 82664 3.INSTALL CONNECTOR HOLDER BLOCK

a.
A155992

Install the connector holder block with the 3 bolts.

Torque:
7.3 N*m (74 kgf*cm, 65 in.*lbf)