Home › Engine / Hybrid System › 3UR-FE ENGINE CONTROL › ECM
RM27M0U _51 Engine / Hybrid System _049094 3UR-FE ENGINE CONTROL _0233921 ECM A

3UR-FE ENGINE CONTROL  ECM  REMOVAL  


PROCEDURE

Hide 82664 1.DISCONNECT CONNECTOR HOLDER BLOCK

a.
A155992

Remove the 3 bolts and move the connector holder block so that the ECM can be removed in the next step.


Hide 89661 2.REMOVE ECM

a.
A167149E02
0.5,0.75 1.563,0.25 true 1.615,0.156 2,0.333 0.385,0.177 10 false Lock 0.604,0.167 0.979,0.469 0.375,0.302 10 true Push

Raise the 2 levers while pushing the locks on the 2 levers.

NOTICE:
A155994

Make sure that the lock lever is raised 90° as shown in the illustration before disconnecting the connectors. Failure to do this may cause the connectors to break.



b.

Disconnect the 2 connectors.


c.
A155993

Remove the 4 bolts and ECM.


Hide 3.REMOVE GASKET

a.
A198571

Peel off the rubber part of the gasket.


b.
A198572E01
2.104,1.639 2.559,1.816 0.456,0.177 10 Cloth 1.452,1.572 1.683,1.725 1.683,1.725 2.063,1.725 false

Spray gasket remover or equivalent on the remaining tape of the gasket.

NOTICE:

When using gasket remover or equivalent, cover the ECM connector with a cloth.



c.
A379728

Remove the tape of the gasket without using bladed objects.