Home › Engine / Hybrid System › 3UR-FBE ENGINE CONTROL › SFI SYSTEM
RM27M0U _51 Engine / Hybrid System _049095 3UR-FBE ENGINE CONTROL _0233928 SFI SYSTEM C

3UR-FBE ENGINE CONTROL  SFI SYSTEM  P2420  Evaporative Emission System Switching Valve Control Circuit High  


DTC SUMMARY

DTC Monitoring Item Malfunction Detection Condition Trouble Area Detection Timing Detection Logic
P2420 Vent valve stuck open (vent) Following condition met during key-off EVAP monitor:
·

EVAP pressure change when vent valve closed (ON) less than 0.3 kPa-g (2.25 mmHg-g)


·

Canister pump module (Reference orifice, leak detection pump, vent valve)

·

Connector/wire harness (Canister pump module - ECM)

·

ECM


While ignition switch off 2 trip

HINT:

The vent valve is built into the canister pump module.


DESCRIPTION

The description can be found in the EVAP (Evaporative Emission) System (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>EVAP System).

CAUTION / NOTICE / HINT

MONITOR DESCRIPTION

5 hours* after the ignition switch is turned off, the leak detection pump creates negative pressure (vacuum) in the EVAP system. The ECM monitors for leaks and actuator malfunctions based on the EVAP pressure.

HINT:

*: If the engine coolant temperature is not below 35°C (95°F) 5 hours after the ignition switch is turned off, the monitor check starts 2 hours later. If it is still not below 35°C (95°F) 7 hours after the ignition switch is turned off, the monitor check starts 2.5 hours later.


Sequence Operation Description Duration
- ECM activation Activated by soak timer 5, 7 or 9.5 hours after ignition switch turned off. -
A Atmospheric pressure measurement Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to register atmospheric pressure.
If pressure in EVAP system not between 70 kPa-a and 111 kPa-a (525 mmHg-a and 833 mmHg-a), ECM cancels EVAP system monitor.
60 seconds
B First reference pressure measurement In order to determine reference pressure, leak detection pump creates negative pressure (vacuum) through reference orifice and then ECM checks if leak detection pump and vent valve operate normally.
·

360 seconds*1

·

300 seconds*2


C EVAP system pressure measurement
·

Vent valve turned ON (closed) to shut EVAP system.

·

Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then measured.

·

Write down measured value as it will be used in leak check.

·

If EVAP pressure does not stabilize within 15 minutes*1, ECM cancels EVAP system monitor.

·

If EVAP pressure does not stabilize within 30 minutes*2, ECM cancels EVAP system monitor.


·

15 minutes*1, *3

·

30 minutes*2, *3


D Purge VSV monitor Purge VSV opened and then EVAP system pressure measured by ECM.
Large increase indicates normality.
10 seconds
E Second reference pressure measurement After second reference pressure measurement, leak check performed by comparing first and second reference pressure.
If stabilized system pressure higher than second reference pressure, ECM determines that EVAP system leaking.
60 seconds
- Final check Atmospheric pressure measured and then monitoring result recorded by ECM. -

HINT:
·

*1: for 100 L (26.4 US gal) Fuel Tank

·

*2: for 144 L (38 US gal) Fuel Tank

·

*3: If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.



A112612E64
1.115,0.51 1.219,0.927 false 1.625,2.188 2,2.396 false 2.458,1.146 2.823,1.083 false 1.813,1.583 2.792,1.375 true 2.417,1.656 2.802,1.635 false 2.583,2.063 2.854,2.063 false 1.219,3.313 1.219,3.438 false 1.271,4.49 1.552,4.51 false 2.313,3.188 1.844,3.948 true 5.083,0.958 5.083,1.083 false 5.667,1.583 6.302,1.292 true 5.292,2.188 5.417,2.146 false 5.76,3.948 6.323,3.615 true 5.188,4.49 5.438,4.5 false 5.094,3.302 5.094,3.438 false 1.594,1.083 1.688,0.677 false 0.646,2.167 1.448,1.948 false 5.01,1.719 4.719,2.344 true 0.104,0.104 3.542,0.292 3.438,0.188 10 false Operation A: Atmospheric Pressure Measurement 0.344,2.75 3.708,2.938 3.365,0.188 10 false Operation C: EVAP System Pressure Measurement 4.469,0.042 5.615,0.229 1.146,0.188 10 false Operation B, E: 4.479,0.333 7.01,0.521 2.531,0.188 10 false Reference Pressure Measurement 4.552,2.698 7,2.917 2.448,0.219 10 false Operation D: Purge VSV Monitor 0.052,0.417 1.208,0.625 1.156,0.208 10 false Purge VSV: OFF 1.729,0.563 2.26,0.74 0.531,0.177 10 false Canister 2.854,0.938 3.49,1.115 0.635,0.177 10 false Fuel Tank 2.854,1.271 4.292,1.448 1.438,0.177 10 false Vent Valve: OFF (vent) 2.854,1.573 4.542,1.792 1.688,0.219 10 false Canister Pump Module 2.917,1.979 3.823,2.156 0.906,0.177 10 false Canister Filter 0.042,1.938 0.646,2.5 0.604,0.563 10 false Canister Pressure Sensor 1.573,2.396 3.354,2.573 1.781,0.177 10 false Leak Detection Pump: OFF 1.073,3.458 1.417,3.635 0.344,0.177 10 false OFF 1.042,4.396 1.323,4.583 0.281,0.188 10 false ON 2.354,3.083 3.115,3.26 0.76,0.177 10 false ON (closed) 3.385,3.521 4.198,3.885 0.813,0.365 10 false Atmospheric Pressure 3.385,4.031 4.063,4.396 0.677,0.365 10 false Negative Pressure 4.927,1.104 5.25,1.281 0.323,0.177 10 false OFF 6.365,1.188 7.083,1.385 0.719,0.198 10 false OFF (vent) 5.021,2.094 5.281,2.271 0.26,0.177 10 false ON 4.104,2.375 6.354,2.563 2.25,0.188 10 false Reference Orifice (0.02 Inch) 5.01,3.458 5.281,3.646 0.271,0.188 10 false ON 4.906,4.396 5.156,4.573 0.25,0.177 10 false ON 6.344,3.563 7.146,3.771 0.802,0.208 10 false ON (closed)

P2420: Vent valve stuck open (vent)

In operation C, the vent valve turns ON (closes) and the EVAP system pressure is then measured by the ECM using the canister pressure sensor to conduct an EVAP leak check. If the pressure does not increase when the vent valve is open, the ECM interprets this as the vent valve being stuck open. The ECM illuminates the MIL and stores the DTC.

U151387E02
3.24,2.906 3.021,3.083 false 0.979,3.156 1.115,3.417 false 3.302,3.719 3.208,3.552 false 0.042,0.01 3.417,0.448 3.375,0.438 12 true EVAP Pressure when Vent Valve Stuck OFF: 0.333,0.448 1.104,0.667 0.771,0.219 10 false Purge VSV 0.438,1.135 1.177,1.344 0.74,0.208 10 false Vent Valve 0.156,1.427 1.177,1.781 1.021,0.354 10 false Leak Detection Pump 0.115,1.927 1.24,2.146 1.125,0.219 10 false EVAP Pressure 0.156,2.188 0.813,2.396 0.656,0.208 10 false Positive 0.156,2.531 0.917,2.74 0.76,0.208 10 false Negative 0.021,2.917 1.01,3.271 0.99,0.354 10 false First Reference Pressure 0.479,4.063 1.167,4.271 0.688,0.208 10 false Sequence 0.219,4.302 1.167,4.51 0.948,0.208 10 false Time (Second) 3.271,3.75 4.292,3.969 1.021,0.219 10 false Malfunction 3.313,2.76 3.698,2.969 0.385,0.208 10 false OK 3.865,1.49 4.26,1.698 0.396,0.208 10 false ON 3.865,0.979 4.26,1.188 0.396,0.208 10 false ON 5.052,0.5 5.448,0.708 0.396,0.208 10 false ON 1.656,4.042 1.885,4.25 0.229,0.208 10 false A 2.531,4.031 2.76,4.24 0.229,0.208 10 false B 3.844,4.01 4.073,4.219 0.229,0.208 10 false C 5.135,4.042 5.365,4.25 0.229,0.208 10 false D 5.688,4.031 5.917,4.24 0.229,0.208 10 false E 6.26,1.26 6.969,1.479 0.708,0.219 10 false OFF: Vent 6.229,0.698 7.104,0.917 0.875,0.219 10 false OFF: Closed 6.229,0.375 6.927,0.594 0.698,0.219 10 false ON: Open 6.229,0.927 7.042,1.146 0.813,0.219 10 false ON: Closed 3.396,4.281 4.76,4.49 1.365,0.208 10 false Within 15 minutes*1 5.104,4.292 5.344,4.5 0.24,0.208 10 false 10 3.396,4.521 4.76,4.729 1.365,0.208 10 true Within 30 minutes*2

HINT:
·

*1: for 100 L (26.4 US gal) Fuel Tank

·

*2: for 144 L (38 US gal) Fuel Tank



MONITOR STRATEGY

Required Sensors/Components Purge VSV and canister pump module
Frequency of Operation Once per driving cycle
Duration Within 7 minutes (varies with amount of fuel in tank)
MIL Operation 2 driving cycles
Sequence of Operation None

TYPICAL ENABLING CONDITIONS

Monitor runs whenever following DTCs not stored None
EVAP key-off monitor runs when all of following conditions met -
Atmospheric pressure 70 to 111 kPa-a (525 to 833 mmHg-a)
Battery voltage 10.5 V or more
Vehicle speed Below 4 km/h (2.5 mph)
Ignition switch Off
Time after key off 5 or 7 or 9.5 hours
Canister pressure sensor malfunction Not detected
Purge VSV Not operated by scan tool
Vent valve Not operated by scan tool
Leak detection pump Not operated by scan tool
Both of following conditions met before key off Conditions 1 and 2
1. Duration that vehicle driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)

TYPICAL MALFUNCTION THRESHOLDS

EVAP pressure change after EVAP canister vent valve ON Less than 0.3 kPa-g (2.25 mmHg-g)

MONITOR RESULT

CONFIRMATION DRIVING PATTERN

NOTICE:
·

The Evaporative System Check (Automatic Mode) consists of 6 steps performed automatically by the Techstream. It takes a maximum of approximately 24 minutes.

·

Do not perform the Evaporative System Check when the fuel tank is more than 90% full because the cut-off valve may be closed, making the fuel tank leak check unavailable.

·

Do not run the engine during this operation.

·

When the temperature of the fuel is 35°C (95°F) or higher, a large amount of vapor forms and any check results become inaccurate. When performing the Evaporative System Check, keep the fuel temperature below 35°C (95°F).



1.

Connect the Techstream to the DLC3.

2.

Turn the ignition switch to ON and turn the Techstream on.

3.

Clear DTCs (even if no DTCs are stored, perform the clear DTC operation).

4.

Turn the ignition switch off and wait for at least 30 seconds.

5.

Turn the ignition switch to ON and turn the Techstream on.

6.

Enter the following menus: Powertrain / Engine and ECT / Utility / Evaporative System Check / Automatic Mode.

7.

After the "Evaporative System Check" is completed, check All Readiness by entering the following menus: Powertrain / Engine and ECT / Utility / All Readiness.

8.

Input the DTC: P2420.

9.

Check the DTC judgment result.

Tester Display Description
NORMAL
·

DTC judgment completed

·

System normal


ABNORMAL
·

DTC judgment completed

·

System abnormal


INCOMPLETE
·

DTC judgment not completed

·

Perform driving pattern after confirming DTC enabling conditions


N/A
·

Unable to perform DTC judgment

·

Number of DTCs which do not fulfill DTC preconditions has reached ECU memory limit



HINT:

If the judgment result shows ABNORMAL, the system has a malfunction.


10.

If the test result is INCOMPLETE or N/A and no pending DTC is output, perform a universal trip and check for permanent DTCs (See page Engine / Hybrid System>3UR-FBE ENGINE CONTROL>SFI SYSTEM>DTC CHECK / CLEAR).

HINT:
·

If a permanent DTC is output, the system is malfunctioning.

·

If no permanent DTC is output, the system is normal.




PROCEDURE

1.GO TO EVAP SYSTEM

NEXT

END