89467B
1.INSPECT AIR FUEL RATIO SENSOR
Disconnect the 2 sensor connectors.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 (HA1A) - 2 (+B)
(for Bank 1) |
20°C (68°F) | 1.6 to 3.2 Ω |
| 1 (HA2A) - 2 (+B)
(for Bank 2) |
If the result is not as specified, replace the sensor.
Reconnect the 2 sensor connectors.