25860
1.INSPECT PURGE VSV
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | 20°C (68°F) | 23 to 26 Ω |
| 1 - VSV body ground | Always | 10 kΩ or higher |
| 2 - VSV body ground | 10 kΩ or higher |
If the result is not as specified, replace the purge VSV.
Inspect the purge VSV operation.
Check that air does not flow from ports.
Apply battery voltage across the terminals.
Check that air flows from ports.
If the result is not as specified, replace the purge VSV.