Home › Engine / Hybrid System › 3UR-FE EMISSION CONTROL › AIR INJECTION DRIVER
RM27M0U _51 Engine / Hybrid System _049100 3UR-FE EMISSION CONTROL _0233983 AIR INJECTION DRIVER A

3UR-FE EMISSION CONTROL  AIR INJECTION DRIVER  INSTALLATION  


PROCEDURE

Hide 1.INSTALL AIR INJECTION CONTROL DRIVER ASSEMBLY

a.
A153553

Install the air injection control driver with the 3 bolts.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


b.
A153552

Connect the 2 wire harness clamps.


c.

Install the ground cable with the bolt.

Torque:
8.0 N*m (82 kgf*cm, 71 in.*lbf)


d.
A153551

Connect the 4 air injection control driver connectors.