Home › Engine / Hybrid System › 1UR-FE EMISSION CONTROL › AIR SWITCHING VALVE(for Bank 1)
RM27M0U _51 Engine / Hybrid System _049101 1UR-FE EMISSION CONTROL _0233990 AIR SWITCHING VALVE(for Bank 1) G

1UR-FE EMISSION CONTROL  AIR SWITCHING VALVE(for Bank 1)  INSPECTION  


PROCEDURE

Hide 25710 1.INSPECT AIR SWITCHING VALVE ASSEMBLY

a.
A266183E03
0.229,0.271 0.406,0.448 0.177,0.177 10 false *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 5 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground Always 1 MΩ or higher
5 - Body ground


Text in Illustration
*a Component without harness connected
(Air Switching Valve Assembly)

NOTICE:

When measuring the resistance, do not touch terminals 2, 3 or 4.


HINT:

When measuring the resistance, make sure that the surface temperature of the air switching valve assembly is 20°C (68°F).


If the result is not as specified, replace the air switching valve assembly.


b.
A266184E04
1.896,2.854 2.104,2.854 2.104,2.854 2.552,2.219 false 0.51,1 0.677,1 0.677,1 0.906,1.719 false 1.688,2.75 1.865,2.938 0.177,0.188 10 false *a 0.292,0.906 0.479,1.083 0.188,0.177 10 false *b

Check the operation of the air switching valve assembly.

i.

Check that air does not flow from port A to port B.

Text in Illustration
*a Port A
*b Port B
V100135

Air

NOTICE:

Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.


If the result is not as specified, replace the air switching valve assembly.


ii.
A266185E04
2.229,4.24 2.365,4.24 2.365,4.24 2.604,3.854 false 0.656,2.74 0.802,2.74 0.802,2.74 1.01,3.396 false 0.208,0.281 0.417,0.49 0.208,0.208 10 false *a 2.042,4.177 2.208,4.344 0.167,0.167 10 false *b 0.458,2.677 0.635,2.865 0.177,0.188 10 false *c

Apply battery voltage across terminals 1 and 5.

Text in Illustration
*a Component without harness connected
(Air Switching Valve Assembly)
*b Port A
*c Port B
V100135

Air

NOTICE:

When applying voltage, do not touch terminals 2, 3 or 4.



iii.

Check that air flows from port A to port B.

If the result is not as specified, replace the air switching valve assembly.