77740Q
1.INSTALL CANISTER PUMP MODULE
Engage the 2 claws to install a new canister pump module to the charcoal canister assembly.
Do not allow foreign matter such as grease, oil or water to adhere to the O-rings.
Ensure that the claws are engaged properly.
77740
2.INSTALL CHARCOAL CANISTER ASSEMBLY
Install the charcoal canister assembly with the 4 bolts.
Attach the wire harness clamp.
Connect the vent line hose.
Push the vent line hose into the port and push the retainer to lock it.
| *1 | Vent Line Hose |
| *2 | Retainer |
|
Push |
Check for damage or foreign objects on the connected part.
After connecting the vent line hose, check that the vent line hose and valve are securely connected by pulling on them.
Connect the air inlet line hose.
Check for damage or foreign objects on the connected part.
After connecting the air inlet line hose, check that the air inlet line hose and valve are securely connected by pulling on them.
Connect the purge line hose and slide the clamp to secure the hose.
Connect the canister pump module connector.
Connect the wiring harness clamp bracket with the nut.