Home › Engine / Hybrid System › 1UR-FE EMISSION CONTROL › AIR SWITCHING VALVE(for Bank 2)
RM27M0U _51 Engine / Hybrid System _049101 1UR-FE EMISSION CONTROL _0233998 AIR SWITCHING VALVE(for Bank 2) G

1UR-FE EMISSION CONTROL  AIR SWITCHING VALVE(for Bank 2)  INSPECTION  


PROCEDURE

Hide 25710 1.INSPECT AIR SWITCHING VALVE ASSEMBLY

a.
A266194E02
0.219,0.271 0.417,0.448 0.198,0.177 10 false *a

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 5 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground Always 1 MΩ or higher
5 - Body ground


Text in Illustration
*a Component without harness connected
(Air Switching Valve Assembly)

NOTICE:

When measuring the resistance, do not touch terminals 2, 3 or 4.


HINT:

When measuring the resistance, make sure that the surface temperature of the air switching valve assembly is 20°C (68°F).


If the result is not as specified, replace the air switching valve assembly.


b.
A266195E03
1.771,0.198 1.99,0.198 1.99,0.198 2.188,1.135 false 1.302,3.115 1.115,3.115 1.115,3.115 0.99,2.688 false 1.552,0.104 1.729,0.281 0.177,0.177 10 false *a 1.323,3.021 1.542,3.198 0.219,0.177 10 false *b

Check the operation of the air switching valve assembly.

i.

Check that air does not flow from port A to port B.

Text in Illustration
*a Port A
*b Port B
V100135

Air

NOTICE:

Make sure the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.


If the result is not as specified, replace the air switching valve assembly.


ii.
A266196E02
0.184,0.224 0.374,0.403 0.191,0.179 10 *a 1.63,1.821 1.817,2.022 0.187,0.201 10 *b 1.83,1.91 2.028,1.91 2.028,1.91 2.283,2.646 false 0.17,3.342 0.356,3.521 0.186,0.179 10 *c 0.384,3.44 0.527,3.44 0.527,3.44 0.679,3.738 false

Apply battery voltage across terminals 1 and 5.

Text in Illustration
*a Component without harness connected
(Air Switching Valve Assembly)
*b Port A
*c Port B
V100135

Air

NOTICE:

When applying voltage, do not touch terminals 2, 3 or 4.



iii.

Check that air flows from port A to port B.

If the result is not as specified, replace the air switching valve assembly.