Home › Drivetrain › AB60F AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY
RM27M0U _52 Drivetrain _049125 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0234131 VALVE BODY ASSEMBLY G

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 1.INSPECT SHIFT SOLENOID VALVE SL1

C351966E03
1.833,1.271 2.313,1.021 true 1.521,1.281 1.052,1.021 true 1.823,3.177 2.302,2.927 true 1.521,3.188 1.073,2.948 true 0.052,0.073 2.521,0.427 2.469,0.354 10 false Component without harness connected: (Shift Solenoid Valve SL1) 0.917,0.917 1.146,1.094 0.229,0.177 10 false 2 0.917,2.823 1.146,3 0.229,0.177 10 false 2 2.375,0.906 2.583,1.083 0.208,0.177 10 false 1 2.375,2.823 2.583,3 0.208,0.177 10 false 1 1.208,4.26 1.438,4.438 0.229,0.177 10 false (-) 2.021,4.271 2.25,4.448 0.229,0.177 10 false (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 2.INSPECT SHIFT SOLENOID VALVE S1

C160563E01
1.71,0.819 1.941,1.002 0.231,0.184 10 (-) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S1: 2.477,0.819 2.709,1.002 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω



b.

Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 3.INSPECT SHIFT SOLENOID VALVE S2

C160564E01
2.349,0.818 2.580,1.001 0.231,0.184 10 (+) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S2: 3.116,0.818 3.347,1.001 0.231,0.184 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω



b.

Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 4.INSPECT SHIFT SOLENOID VALVE S3

C160563E02
1.71,0.819 1.941,1.002 0.231,0.184 10 (-) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S3: 2.477,0.819 2.709,1.002 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body 20°C (68°F) 11 to 15 Ω



b.

Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 5.INSPECT SHIFT SOLENOID VALVE S4

C123198E03
1.644,0.82 1.876,1.003 0.231,0.184 10 (-) 0.055,0 1.632,0.186 1.577,0.186 10 Shift Solenoid Valve S4: 2.412,0.82 2.643,1.003 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body 20°C (68°F) 11 to 15 Ω



b.

Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 6.INSPECT SHIFT SOLENOID VALVE SL2

C351966E05
1.833,1.271 2.313,1.021 true 1.521,1.281 1.052,1.021 true 1.823,3.177 2.302,2.927 true 1.521,3.188 1.073,2.948 true 0.052,0.031 2.521,0.385 2.469,0.354 10 false Component without harness connected: (Shift Solenoid Valve SL2) 0.917,0.917 1.146,1.094 0.229,0.177 10 false 2 0.917,2.823 1.146,3 0.229,0.177 10 false 2 2.375,0.906 2.583,1.083 0.208,0.177 10 false 1 2.375,2.823 2.583,3 0.208,0.177 10 false 1 1.208,4.26 1.438,4.438 0.229,0.177 10 false (-) 2.021,4.271 2.25,4.448 0.229,0.177 10 false (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 7.INSPECT SHIFT SOLENOID VALVE SR

C160565E01
2.349,0.818 2.580,1.002 0.231,0.184 10 (+) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve SR: 3.116,0.818 3.347,1.002 0.231,0.184 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



b.

Connect the battery's positive (+) lead to the terminal of the solenoid valve connector, and the negative (-) lead to the solenoid valve body. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 8.INSPECT SHIFT SOLENOID VALVE SLT

C351967E04
1.125,0.99 1.531,1.25 true 2.281,1 1.885,1.25 true 2.281,2.979 1.885,3.229 true 1.125,2.969 1.531,3.229 true 0.063,0.063 2.5,0.406 2.438,0.344 10 false Component without harness connected: (Shift Solenoid Valve SLT) 1,0.906 1.104,1.104 0.104,0.198 10 false 2 2.313,0.917 2.417,1.115 0.104,0.198 10 false 1 1.01,2.865 1.115,3.063 0.104,0.198 10 false 2 2.313,2.896 2.417,3.094 0.104,0.198 10 false 1 1.271,4.344 1.49,4.542 0.219,0.198 10 false (+) 1.99,4.344 2.156,4.542 0.167,0.198 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.


If the result is not as specified, replace the solenoid valve.


Hide 9.INSPECT SHIFT SOLENOID VALVE SLU

C351967E02
1.125,0.99 1.531,1.25 true 2.281,1 1.885,1.25 true 2.281,2.979 1.885,3.229 true 1.125,2.969 1.531,3.229 true 0.063,0.063 2.5,0.406 2.438,0.344 10 false Component without harness connected: (Shift Solenoid Valve SLU) 1,0.906 1.104,1.104 0.104,0.198 10 false 2 2.313,0.917 2.417,1.115 0.104,0.198 10 false 1 1.01,2.865 1.115,3.063 0.104,0.198 10 false 2 2.313,2.896 2.417,3.094 0.104,0.198 10 false 1 1.271,4.344 1.49,4.542 0.219,0.198 10 false (+) 1.99,4.344 2.156,4.542 0.167,0.198 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.


If the result is not as specified, replace the solenoid valve.