When moving the shift lever into the S position using the transmission control switch, it is possible to switch the shift range position between "1" (1st range) and "6" (6th range).
Shifting to "+" once raises the shift range position by one, and shifting to "-" lowers the shift range position by one.
for Column Shift Type:
Disconnect the J25 transmission control switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 6 (IG) - 13 (S) | Shift lever position on S, "+" or "-" | Below 1 Ω |
| 5 (SFTU) - 11 (E) | Shift lever held in "+"
(Up-shift) |
Below 1 Ω |
| 4 (SFTD) - 11 (E) | Shift lever held in "-"
(Down-shift) |
Below 1 Ω |
| 6 (IG) - 13 (S) | Shift lever position not on S, "+" or "-" | 10 kΩ or higher |
| 5 (SFTU) - 11 (E) | Shift lever position on S | 10 kΩ or higher |
| 4 (SFTD) - 11 (E) | Shift lever position on S | 10 kΩ or higher |
for Floor Shift Type:
Disconnect the J24 transmission control switch connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 3 (IG) - 7 (S) | Shift lever position on S, "+" or "-" | Below 1 Ω |
| 2 (SFTU) - 5 (E) | Shift lever held in "+"
(Up-shift) |
Below 1 Ω |
| 1 (SFTD) - 5 (E) | Shift lever held in "-"
(Down-shift) |
Below 1 Ω |
| 3 (IG) - 7 (S) | Shift lever position not on S, "+" or "-" | 10 kΩ or higher |
| 2 (SFTU) - 5 (E) | Shift lever position on S | 10 kΩ or higher |
| 1 (SFTD) - 5 (E) | Shift lever position on S | 10 kΩ or higher |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for Column Shift Type) | B |
| NG (for Floor Shift Type) | C |
A
B
C
for Column Shift Type:
Disconnect the J25 transmission control switch connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J25-6 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| J25-6 (IG) - Body ground | Ignition switch off | Below 1 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J25-11 (E) - Body ground | Always | Below 1 Ω |
for Floor Shift Type:
Disconnect the J24 transmission control switch connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
| J24-3 (IG) - Body ground | Ignition switch ON | 11 to 14 V |
| J24-3 (IG) - Body ground | Ignition switch off | Below 1 V |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J24-5 (E) - Body ground | Always | Below 1 Ω |
OK
NG
Disconnect the A24 ECM connector.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-25 (S) - Body ground | ·
Ignition switch ON ·
Shift lever position on S, "+" or "-" |
11 to 14 V |
| A24-25 (S) - Body ground | ·
Ignition switch ON ·
Shift lever position not on S, "+" or "-" |
Below 1 V |
Turn the ignition switch off.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| A24-38 (SFTU) - Body ground | Shift lever held in "+"
(Up-shift) |
Below 1 Ω |
| A24-27 (SFTD) - Body ground | Shift lever held in "-"
(Down-shift) |
Below 1 Ω |
| A24-38 (SFTU) - Body ground | Shift lever position on S | 10 kΩ or higher |
| A24-27 (SFTD) - Body ground | Shift lever position on S | 10 kΩ or higher |
OK
NG