Home › Drivetrain › AB60F AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM27M0U _52 Drivetrain _049125 AB60F AUTOMATIC TRANSMISSION / TRANSAXLE _0234142 AUTOMATIC TRANSMISSION SYSTEM C

AB60F AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  P2757  Torque Converter Clutch Pressure Control Solenoid Performance (Shift Solenoid Valve SLU)  


DESCRIPTION

The ECM uses the signals from the throttle position sensor, air-flow meter, turbine (input) speed sensor, output speed sensor and crankshaft position sensor to monitor the engagement condition of the lock-up clutch.

C221407E01
4.729,2.135 5.031,1.188 5.031,1.188 5.094,1.188 true 4.969,2.323 5.125,2.688 5.125,2.688 5.188,2.688 true 5.76,2.396 5.917,2.688 5.917,2.688 5.979,2.688 true 6.031,2.594 6.917,2.813 0.885,0.219 10 false Solenoid Coil 0.135,0.688 1.385,0.906 1.25,0.219 10 false Hydraulic Pressure 2.573,3.01 3.135,3.229 0.563,0.219 10 false Current 5.24,2.615 5.771,2.833 0.531,0.219 10 false Sleeve 5.167,1.104 6.01,1.323 0.844,0.219 10 false Spool Valve

Then the ECM compares the engagement condition of the lock-up clutch with the lock-up schedule in the ECM memory to detect mechanical problems of the shift solenoid valve SLU, valve body and torque converter.

DTC Code DTC Detection Condition Trouble Area
P2757 Lock-up does not occur when driving in the lock-up range (normal driving at 80 km/h (50 mph)), or lock-up remains ON in the lock-up OFF range
(2 trip detection logic)
·

Shift solenoid valve SLU remains open or closed

·

Valve body is blocked

·

Shift solenoid valve SLU

·

Torque converter

·

Automatic transmission (clutch, brake, gear, etc.)

·

Line pressure is too low



MONITOR DESCRIPTION

Torque converter lock-up is controlled by the ECM based on the turbine (input) speed sensor NT, output speed sensor SP2, engine rpm, engine load, engine temperature, vehicle speed, transmission temperature, and gear selection. The ECM determines the lock-up status of the torque converter by comparing the engine rpm (NE) to the input turbine rpm (NT). The ECM calculates the actual transmission gear by comparing input turbine rpm (NT) to output shaft rpm (SP2). When conditions are appropriate, the ECM requests lock-up by applying control voltage to shift solenoid SLU. When SLU is turned ON, it applies pressure to the lock-up relay valve and locks the torque converter.

If the ECM detects no lock-up after lock-up has been requested or if it detects lock-up when it is not requested, the ECM interprets this as a fault in the shift solenoid valve SLU or lock-up system performance.

The ECM will illuminate the MIL and store the DTC.

Example:

When one of the following conditions is met, the system determines that there is a malfunction.

·

There is a difference in rotation between the input side (engine speed) and output side (input turbine speed) of the torque converter when the ECM commands lock-up ON.

Engine speed is at least 70 rpm greater than input turbine speed.

·

There is no difference in rotation between the input side (engine speed) and output side (input turbine speed) of the torque converter when the ECM commands lock-up OFF.

The difference between engine speed and input turbine speed is less than 35 rpm.


MONITOR STRATEGY

Related DTCs P2757: Shift solenoid valve SLU/Functional check
Required sensors/Components Shift solenoid valve SLU
Frequency of operation Continuous
Duration OFF malfunction (A)
2 seconds
OFF malfunction (B)
0.4 seconds
ON malfunction
1.8 seconds
MIL operation 2 driving cycles
Sequence of operation None

TYPICAL ENABLING CONDITIONS

All
The monitor will run whenever the following DTCs are not present P0717 (Turbine speed sensor circuit)
P0722 (Output speed sensor circuit)
P0973, P0974 (Shift solenoid valve S1 circuit)
P0976, P0977 (Shift solenoid valve S2 circuit)
P0761, P0979, P0980 (Shift solenoid valve S3 circuit)
P0766, P0982, P0983 (Shift solenoid valve S4 circuit)
P0985, P0986 (Shift solenoid valve SR circuit)
P2759 (Torque converter clutch pressure control solenoid circuit)
P0327, P0328, P032C, P032D (KCS sensor circuit)
P0778 (Shift solenoid valve SL2 circuit)
P0781 (1 - 2 shift valve)
P0729 (Reverse sequence valve)
ETCS (Electric Throttle Control System) Not system down
Transmission position "D"
Duration time from shifting "N" to "D" 4 seconds or more
ECT (Engine coolant temperature) 40°C (104°F) or higher
Spark advance from max. retard timing by KCS control 0° crankshaft angle or more
Engine Starting
ECM selected gear 2nd, 3rd, 4th, 5th or 6th
Vehicle speed 25 km/h (15.5 mph) or more
Transfer position HIGH*

HINT:

*: Following conditions met

Vehicle speed sensor circuit Not circuit malfunction
Output shaft speed sensor circuit Not circuit malfunction
Transfer output speed 143 rpm or more
Transfer input speed/Transfer output speed (NO/NOtf) 0.9 or more, and less than 1.1


OFF Malfunction (A)
ECM lock-up command ON
(SLU pressure: 513 kPa (5.2 kgf/cm2, 74 psi) or more)
Duration time from lock-up on command 3 seconds or more
Input speed/output speed (NT/NO)
NT: Input (Turbine) speed
NO: Internal counter shaft speed
0.66 to 0.80
or
0.51 to 0.65
Calculated load value A/C off:
17.4% or more when turbine speed is 375 rpm
A/C on:
18.6% or more when turbine speed is 375 rpm
(Conditions vary with turbine speed)
Vehicle speed Less than 120 km/h (74.6 mph)

OFF Malfunction (B)
ECM selected gear 2nd
Vehicle speed 2 km/h (1.2 mph) or more
Output speed 2nd → 1st down-shift point or more
Throttle valve opening angle 9% or more at 2000 rpm
(Conditions vary with engine speed)
Calculated load value 7.75% or more (A/C off)
7.75% or more (A/C on)
Input speed/output speed (NT/NO)
NT: Input (Turbine) speed
NO: Internal counter shaft speed
3.11 to 7.58
or
1.83 to 2.27
or
1.24 to 1.49
or
0.93 to 1.07
or
0.66 to 0.80
or
0.51 to 0.65

ON Malfunction
ECM lock-up command OFF
(SLU pressure: Less than 4 kPa (0.04 kgf/cm2, 0.6 psi))
Duration time from lock-up off command 3 seconds or more
Throttle valve opening angle 6% or more
Input speed/output speed (NT/NO)
NT: Input (Turbine) speed
NO: Internal counter shaft speed
1.83 to 2.27
or
1.24 to 1.49
or
0.93 to 1.07
or
0.66 to 0.80
or
0.51 to 0.65
Calculated load value A/C off:
17.4% or more when turbine speed is 375 rpm
A/C on:
18.6% or more when turbine speed is 375 rpm
(Conditions vary with turbine speed)
Vehicle speed Less than 120 km/h (74.6 mph)

TYPICAL MALFUNCTION THRESHOLDS

[OFF malfunction]

Both of the following conditions are met: OFF malfunction (A) and (B)


OFF Malfunction (A)
Engine speed - Turbine speed (NE - NT) 70 rpm or more

OFF Malfunction (B)
Turbine speed/Output speed (NT/NO) Less than 3.11 or more than 7.58

[ON malfunction]

2 detections are necessary per driving cycle:

1st detection: temporary flag ON

2nd detection: pending fault code ON

Vehicle speed must be under 10 km/h (6.2 mph) once before 2nd detection.


ON Malfunction
Engine speed - Turbine speed (NE - NT) Less than 35 rpm

COMPONENT OPERATING RANGE

Speed sensor (NT) Input speed is equal to engine speed when lock-up ON.

CAUTION / NOTICE / HINT

NOTICE:

Perform the universal trip to clear permanent DTCs (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>AUTOMATIC TRANSMISSION SYSTEM>DTC CHECK / CLEAR).


ACTIVE TEST


HINT:

Using the Techstream to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


a.

Warm up the engine.


b.

Turn the ignition switch off.


c.

Connect the Techstream to the DLC3.


d.

Turn the ignition switch to ON.


e.

Turn the Techstream on.


f.

Enter the following menus: Powertrain / Engine and ECT / Active Test.


g.

According to the display on the Techstream, perform the Active Test.

Engine and ECT:
Tester Display Test Part Control Range Diagnostic Note
Activate the Lock Up Control shift solenoid SLU to set automatic transmission to lock-up condition ON or OFF Possible to check shift solenoid valve SLU operation
[Vehicle Condition]
·

Throttle valve opening angle: Less than 35%

·

Vehicle speed: 80 km/h (50 mph) or more



HINT:
·

This test can be conducted when the vehicle speed is 80 km/h (50 mph) or more.

·

Perform this test while driving in 5th or 6th gear.




h.

Lightly depress the accelerator pedal and check that the engine speed does not change abruptly.

C159073E01
4.531,2.188 5.51,1.958 5.51,1.958 5.573,1.958 false 5.198,2.229 5.542,2.615 5.542,2.615 5.604,2.615 false 0.719,2.677 1.677,2.948 0.958,0.271 10 false Engine Speed 0.719,1.677 1.813,2.156 1.094,0.479 10 false Accelerator Pedal Fully Released 0.719,1.021 1.823,1.542 1.104,0.521 10 false Accelerator Pedal Opening Angle 4.99,3.125 5.438,3.323 0.448,0.198 10 false Time 5.656,1.865 6.615,2.146 0.958,0.281 10 false Lock-up OFF 5.656,2.49 6.646,2.708 0.99,0.219 10 false Lock-up ON

HINT:
·

When changing the accelerator pedal opening angle while driving, if the engine speed does not change, lock-up is on.

·

Slowly release the accelerator pedal in order to decelerate, but do not fully release the pedal. (Fully releasing the pedal will close the throttle valve and lock-up may be turned off automatically.)





PROCEDURE

1.CHECK DTC OUTPUT (IN ADDITION TO DTC P2757)
a.

Connect the Techstream to the DLC3.


b.

Turn the ignition switch to ON.


c.

Turn the Techstream on.


d.

Enter the following menus: Powertrain / Engine and ECT / Trouble Codes.


e.

Read the DTCs using the Techstream.

Result
Result Proceed to
Only P2757 is output A
P2757 and other DTCs are output B

HINT:

If any other codes besides P2757 are output, perform troubleshooting for those DTCs first.




A

2.INSPECT SHIFT SOLENOID VALVE SLU

B

2.INSPECT SHIFT SOLENOID VALVE SLU
a.

Remove shift solenoid valve SLU.


C351967E03
1.125,0.99 1.531,1.25 true 2.281,1 1.885,1.25 true 2.281,2.979 1.885,3.229 true 1.125,2.969 1.531,3.229 true 0.063,0.063 2.5,0.406 2.438,0.344 10 false Component without harness connected: (Shift Solenoid Valve SLU) 1,0.906 1.104,1.104 0.104,0.198 10 false 2 2.313,0.917 2.417,1.115 0.104,0.198 10 false 1 1.01,2.865 1.115,3.063 0.104,0.198 10 false 2 2.313,2.896 2.417,3.094 0.104,0.198 10 false 1 1.271,4.344 1.49,4.542 0.219,0.198 10 false (+) 1.99,4.344 2.156,4.542 0.167,0.198 10 false (-)

b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



c.

Connect the battery's positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating noise.

OK:

Valve moves and makes an operating noise.




OK

3.INSPECT TRANSMISSION VALVE BODY ASSEMBLY

NG

3.INSPECT TRANSMISSION VALVE BODY ASSEMBLY
a.

Check the transmission valve body assembly (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>VALVE BODY ASSEMBLY>DISASSEMBLY).

OK:

There are no foreign objects on any valve.




OK

4.INSPECT TORQUE CONVERTER ASSEMBLY

NG

REPLACE TRANSMISSION VALVE BODY ASSEMBLY

4.INSPECT TORQUE CONVERTER ASSEMBLY
a.

Check the torque converter assembly (See page Drivetrain>AB60F AUTOMATIC TRANSMISSION / TRANSAXLE>TORQUE CONVERTER CLUTCH AND DRIVE PLATE>INSPECTION).

OK:

The torque converter operates normally.




OK

REPAIR OR REPLACE AUTOMATIC TRANSMISSION ASSEMBLY

NG