Home › Drivetrain › AB60E AUTOMATIC TRANSMISSION / TRANSAXLE › AUTOMATIC TRANSMISSION SYSTEM
RM27M0U _52 Drivetrain _049126 AB60E AUTOMATIC TRANSMISSION / TRANSAXLE _0234159 AUTOMATIC TRANSMISSION SYSTEM J

AB60E AUTOMATIC TRANSMISSION / TRANSAXLE  AUTOMATIC TRANSMISSION SYSTEM  Transmission Control Switch Circuit  


DESCRIPTION

When moving the shift lever into the S position using the transmission control switch, it is possible to switch the shift range position between "1" (1st range) and "6" (6th range).

Shifting to "+" once raises the shift range position by one, and shifting to "-" lowers the shift range position by one.

WIRING DIAGRAM

C160114E02
5.646,0.813 5.875,0.979 0.229,0.167 10 false 25 4.396,2.125 4.698,2.292 0.302,0.167 10 false 1*2 3.948,1.74 4.417,1.938 0.469,0.198 10 false SFTD 4.396,1.531 4.677,1.698 0.281,0.167 10 false 2*2 3.948,1.156 4.417,1.354 0.469,0.198 10 false SFTU 4.396,0.948 4.677,1.115 0.281,0.167 10 false 7*2 4.177,0.552 4.302,0.75 0.125,0.198 10 false S 2.74,0.948 3.021,1.115 0.281,0.167 10 false 3*2 3.031,0.563 3.271,0.76 0.24,0.198 10 false IG 2.74,2.125 3.042,2.292 0.302,0.167 10 false 5*2 3.063,1.74 3.302,1.938 0.24,0.198 10 false E 5.969,0.688 6.396,0.885 0.427,0.198 10 false S 5.646,1.375 5.875,1.542 0.229,0.167 10 false 38 5.969,1.281 6.396,1.479 0.427,0.198 10 false SFTU 5.646,1.958 5.875,2.125 0.229,0.167 10 false 27 5.969,1.854 6.396,2.052 0.427,0.198 10 false SFTD 2.802,2.333 3.229,2.531 0.427,0.198 10 false J25*1 2.802,2.698 4.583,2.896 1.781,0.198 10 false Transmission Control Switch 0.375,0.667 1.688,0.865 1.313,0.198 10 false from Ignition Switch 6.146,2.594 6.448,2.76 0.302,0.167 10 false A24 6.146,2.75 6.573,2.948 0.427,0.198 10 false ECM 2.74,0.802 3.031,0.969 0.292,0.167 10 false 6*1 2.667,1.969 3.021,2.135 0.354,0.167 10 false 11*1 4.396,0.802 4.76,0.969 0.365,0.167 10 false 13*1 4.396,1.375 4.677,1.542 0.281,0.167 10 false 5*1 4.396,1.969 4.719,2.135 0.323,0.167 10 false 4*1 2.802,2.51 3.229,2.708 0.427,0.198 10 false J24*2 0.042,2.927 1.677,3.125 1.635,0.198 10 false *1: for Column Shift Type 0.042,3.302 1.677,3.5 1.635,0.198 10 false *2: for Floor Shift Type

PROCEDURE

1.INSPECT TRANSMISSION CONTROL SWITCH
a.
C159524E11
1.438,1.563 0.76,1.469 true 0.76,2.177 1.438,1.854 true 1.729,1.563 2.688,1.24 true 1.542,1.563 0.719,1.24 true 2.688,2.177 1.729,1.854 true 0.052,0.052 2.583,0.417 2.531,0.365 10 false Component without harness connected: (Transmission Control Switch) 0.583,1.375 0.833,1.573 0.25,0.198 10 false IG 0.615,2.104 0.781,2.302 0.167,0.198 10 false S 2.719,1.104 3.177,1.302 0.458,0.198 10 false SFTD 2.75,2.094 2.948,2.292 0.198,0.198 10 false E 0.354,1.115 0.813,1.313 0.458,0.198 10 false SFTU

for Column Shift Type:

i.

Disconnect the J25 transmission control switch connector.


ii.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
6 (IG) - 13 (S) Shift lever position on S, "+" or "-" Below 1 Ω
5 (SFTU) - 11 (E) Shift lever held in "+"
(Up-shift)
Below 1 Ω
4 (SFTD) - 11 (E) Shift lever held in "-"
(Down-shift)
Below 1 Ω
6 (IG) - 13 (S) Shift lever position not on S, "+" or "-" 10 kΩ or higher
5 (SFTU) - 11 (E) Shift lever position on S 10 kΩ or higher
4 (SFTD) - 11 (E) Shift lever position on S 10 kΩ or higher




b.
C146679E25
1.583,1.302 0.906,1.052 true 0.927,1.844 1.604,1.594 true 1.781,1.281 2.625,1.031 true 1.99,1.323 2.667,1.323 true 2.646,1.844 1.969,1.594 true 0.052,0.083 2.583,0.448 2.531,0.365 10 false Component without harness connected: (Transmission Control Switch) 0.729,0.958 0.979,1.156 0.25,0.198 10 false IG 0.771,1.74 0.938,1.938 0.167,0.198 10 false S 2.719,0.896 3.229,1.094 0.51,0.198 10 false SFTU 2.719,1.229 3.229,1.427 0.51,0.198 10 false SFTD 2.698,1.771 2.875,1.969 0.177,0.198 10 false E

for Floor Shift Type:

i.

Disconnect the J24 transmission control switch connector.


ii.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
3 (IG) - 7 (S) Shift lever position on S, "+" or "-" Below 1 Ω
2 (SFTU) - 5 (E) Shift lever held in "+"
(Up-shift)
Below 1 Ω
1 (SFTD) - 5 (E) Shift lever held in "-"
(Down-shift)
Below 1 Ω
3 (IG) - 7 (S) Shift lever position not on S, "+" or "-" 10 kΩ or higher
2 (SFTU) - 5 (E) Shift lever position on S 10 kΩ or higher
1 (SFTD) - 5 (E) Shift lever position on S 10 kΩ or higher


Result
Result Proceed to
OK A
NG (for Column Shift Type) B
NG (for Floor Shift Type) C




A

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - BATTERY, BODY GROUND)

B

REPLACE COLUMN SHIFT SHIFT LEVER SUB-ASSEMBLY (TRANSMISSION CONTROL SWITCH)

C

REPLACE TRANSMISSION FLOOR SHIFT ASSEMBLY (TRANSMISSION CONTROL SWITCH)

2.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - BATTERY, BODY GROUND)
a.
U152212E02
2.073,1.646 2.646,1.333 true 2.646,2.344 1.719,2.021 true 0.396,1.677 0.771,1.906 0.375,0.229 10 false J25 0.063,0.042 2.469,0.406 2.406,0.365 10 false Front view of wire harness connector: (to Transmission Control Switch) 2.698,1.188 2.938,1.385 0.24,0.198 10 false IG 2.698,2.302 2.938,2.5 0.24,0.198 10 false E

for Column Shift Type:

i.

Disconnect the J25 transmission control switch connector.


ii.

Measure the voltage according to the value(s) in the table below.

Standard voltage:
Tester Connection Switch Condition Specified Condition
J25-6 (IG) - Body ground Ignition switch ON 11 to 14 V
J25-6 (IG) - Body ground Ignition switch off Below 1 V



iii.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
J25-11 (E) - Body ground Always Below 1 Ω




b.
U152129E02
1.823,1.771 2.396,1.458 true 0.823,2.479 1.406,2.167 true 0.49,1.688 0.865,1.917 0.375,0.229 10 false J24 0.052,0.083 2.458,0.448 2.406,0.365 10 false Front view of wire harness connector: (to Transmission Control Switch) 0.688,2.427 0.885,2.625 0.198,0.198 10 false E 2.448,1.292 2.688,1.49 0.24,0.198 10 false IG

for Floor Shift Type:

i.

Disconnect the J24 transmission control switch connector.


ii.

Measure the voltage according to the value(s) in the table below.

Standard voltage:
Tester Connection Switch Condition Specified Condition
J24-3 (IG) - Body ground Ignition switch ON 11 to 14 V
J24-3 (IG) - Body ground Ignition switch off Below 1 V



iii.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
J24-5 (E) - Body ground Always Below 1 Ω





OK

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR

3.CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)
a.
U152249E02
1.979,2.885 2.156,2.063 true 2.927,2.896 2.146,1.844 true 1.198,2.896 1.99,1.844 true 0.052,0.073 2.458,0.438 2.406,0.365 10 false Front view of wire harness connector: (to ECM) 1.688,1.042 2.063,1.271 0.375,0.229 10 false A24 0.885,2.917 1.365,3.115 0.479,0.198 10 false 25 (S) 1.521,2.917 2.281,3.115 0.76,0.198 10 false 38 (SFTU) 2.583,2.917 3.271,3.115 0.688,0.198 10 false 27 (SFTD)

Disconnect the A24 ECM connector.


b.

Measure the voltage according to the value(s) in the table below.

Standard voltage:
Tester Connection Condition Specified Condition
A24-25 (S) - Body ground
·

Ignition switch ON

·

Shift lever position on S, "+" or "-"


11 to 14 V
A24-25 (S) - Body ground
·

Ignition switch ON

·

Shift lever position not on S, "+" or "-"


Below 1 V



c.

Turn the ignition switch off.


d.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
A24-38 (SFTU) - Body ground Shift lever held in "+"
(Up-shift)
Below 1 Ω
A24-27 (SFTD) - Body ground Shift lever held in "-"
(Down-shift)
Below 1 Ω
A24-38 (SFTU) - Body ground Shift lever position on S 10 kΩ or higher
A24-27 (SFTD) - Body ground Shift lever position on S 10 kΩ or higher




OK

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR