Home › Drivetrain › A760E AUTOMATIC TRANSMISSION / TRANSAXLE › VALVE BODY ASSEMBLY
RM27M0U _52 Drivetrain _049128 A760E AUTOMATIC TRANSMISSION / TRANSAXLE _0234191 VALVE BODY ASSEMBLY G

A760E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 1.INSPECT SHIFT SOLENOID VALVE SL1

C351966E01
1.833,1.25 2.313,1 true 1.5,1.26 1.031,1 true 1.833,3.156 2.313,2.906 true 1.5,3.167 1.052,2.927 true 0.052,0.073 2.521,0.427 2.469,0.354 10 false Component without harness connected: (Shift Solenoid Valve SL1) 0.917,0.917 1.146,1.094 0.229,0.177 10 false 2 0.917,2.823 1.146,3 0.229,0.177 10 false 2 2.375,0.906 2.583,1.083 0.208,0.177 10 false 1 2.375,2.823 2.583,3 0.208,0.177 10 false 1 1.208,4.26 1.438,4.438 0.229,0.177 10 false (-) 2.021,4.271 2.25,4.448 0.229,0.177 10 false (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) with a 21 W bulb → Terminal 1
Battery negative (-) → Terminal 2
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 2.INSPECT SHIFT SOLENOID VALVE S1

C160563E01
1.71,0.819 1.941,1.002 0.231,0.184 10 (-) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S1: 2.477,0.819 2.709,1.002 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S1 connector terminal - Shift solenoid valve S1 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Shift solenoid valve S1 connector
Battery negative (-) → Shift solenoid valve S1 body
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 3.INSPECT SHIFT SOLENOID VALVE S2

C160564E01
2.349,0.818 2.580,1.001 0.231,0.184 10 (+) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S2: 3.116,0.818 3.347,1.001 0.231,0.184 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Shift solenoid valve S2 connector
Battery negative (-) → Shift solenoid valve S2 body
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 4.INSPECT SHIFT SOLENOID VALVE S3

C160563E02
1.71,0.819 1.941,1.002 0.231,0.184 10 (-) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve S3: 2.477,0.819 2.709,1.002 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S3 connector terminal - Shift solenoid valve S3 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Shift solenoid valve S3 connector
Battery negative (-) → Shift solenoid valve S3 body
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 5.INSPECT SHIFT SOLENOID VALVE S4

C123198E03
1.644,0.82 1.876,1.003 0.231,0.184 10 (-) 0.055,0 1.632,0.186 1.577,0.186 10 Shift Solenoid Valve S4: 2.412,0.82 2.643,1.003 0.231,0.184 10 (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Shift solenoid valve S4 connector
Battery negative (-) → Shift solenoid valve S4 body
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 6.INSPECT SHIFT SOLENOID VALVE SL2

C351966E02
1.833,1.25 2.313,1 true 1.5,1.26 1.031,1 true 1.833,3.156 2.313,2.906 true 1.5,3.167 1.052,2.927 true 0.052,0.073 2.5,0.417 2.448,0.344 10 false Component without harness connected: (Shift Solenoid Valve SL2) 0.917,0.917 1.146,1.094 0.229,0.177 10 false 2 0.917,2.823 1.146,3 0.229,0.177 10 false 2 2.375,0.906 2.583,1.083 0.208,0.177 10 false 1 2.375,2.823 2.583,3 0.208,0.177 10 false 1 1.208,4.26 1.438,4.438 0.229,0.177 10 false (-) 2.021,4.271 2.25,4.448 0.229,0.177 10 false (+)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) with a 21 W bulb → Terminal 1
Battery negative (-) → Terminal 2
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 7.INSPECT SHIFT SOLENOID VALVE SR

C160565E01
2.349,0.818 2.580,1.002 0.231,0.184 10 (+) 0.056,0 1.633,0.186 1.577,0.186 10 Shift Solenoid Valve SR: 3.116,0.818 3.347,1.002 0.231,0.184 10 (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) → Shift solenoid valve SR connector
Battery negative (-) → Shift solenoid valve SR body
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 8.INSPECT SHIFT SOLENOID VALVE SLT

C351967E01
1.125,0.99 1.531,1.25 true 2.281,1 1.885,1.25 true 2.281,2.979 1.885,3.229 true 1.125,2.969 1.531,3.229 true 0.063,0.063 2.5,0.406 2.438,0.344 10 false Component without harness connected: (Shift Solenoid Valve SLT) 1,0.906 1.104,1.104 0.104,0.198 10 false 2 2.313,0.917 2.417,1.115 0.104,0.198 10 false 1 1.01,2.865 1.115,3.063 0.104,0.198 10 false 2 2.313,2.896 2.417,3.094 0.104,0.198 10 false 1 1.271,4.344 1.49,4.542 0.219,0.198 10 false (+) 1.99,4.344 2.156,4.542 0.167,0.198 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) with a 21 W bulb → Terminal 2
Battery negative (-) → Terminal 1
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.


Hide 9.INSPECT SHIFT SOLENOID VALVE SLU

C351967E02
1.125,0.99 1.531,1.25 true 2.281,1 1.885,1.25 true 2.281,2.979 1.885,3.229 true 1.125,2.969 1.531,3.229 true 0.063,0.063 2.5,0.406 2.438,0.344 10 false Component without harness connected: (Shift Solenoid Valve SLU) 1,0.906 1.104,1.104 0.104,0.198 10 false 2 2.313,0.917 2.417,1.115 0.104,0.198 10 false 1 1.01,2.865 1.115,3.063 0.104,0.198 10 false 2 2.313,2.896 2.417,3.094 0.104,0.198 10 false 1 1.271,4.344 1.49,4.542 0.219,0.198 10 false (+) 1.99,4.344 2.156,4.542 0.167,0.198 10 false (-)

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω



b.

Apply 12 V battery voltage to the shift solenoid valve and check that the valve moves and makes an operating noise.

OK:
Measurement Condition Specified Condition
Battery positive (+) with a 21 W bulb → Terminal 2
Battery negative (-) → Terminal 1
Valve moves and makes an operating noise


If the result is not as specified, replace the solenoid valve.