Home › Engine / Hybrid System › 1UR-FE CHARGING › GENERATOR
RM27M0U _51 Engine / Hybrid System _049146 1UR-FE CHARGING _0234376 GENERATOR G

1UR-FE CHARGING  GENERATOR  INSPECTION  


PROCEDURE

Hide 27330 1.INSPECT GENERATOR ROTOR ASSEMBLY

a.
A117220

Check the rotor for an open circuit.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
100 A Type Type
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 2.3 to 2.7 Ω

150 A Type
Tester Connection Condition Specified Condition
Slip ring - Slip ring 20°C (68°F) 1.5 to 1.9 Ω


If the result is not as specified, replace the generator rotor assembly.



b.
A117221

Check if the rotor is grounded.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
Slip ring - Rotor Always 10 kΩ or higher


If the result is not as specified, replace the generator rotor assembly.



c.

Check that the slip rings are not rough or scored.

If rough or scored, replace the generator rotor assembly.


d.
A117222E05
0.438,0.417 1.031,0.604 0.594,0.188 10 true Diameter

Using a vernier caliper, measure the slip ring diameter.

Standard diameter:

14.2 to 14.4 mm (0.559 to 0.567 in.)


Minimum diameter:

14.0 mm (0.551 in.)


If the diameter is less than the minimum, replace the generator rotor assembly.


Hide 27370 2.INSPECT GENERATOR BRUSH HOLDER ASSEMBLY

A079305E02
0.619,0.394 1.113,0.601 0.494,0.207 10 Length

a.

Using a vernier caliper, measure the exposed brush length.

Standard exposed length:

10.5 mm (0.413 in.)


Minimum exposed length:

4.5 mm (0.177 in.)


If the exposed length is less than the minimum, replace the generator brush holder assembly.


Hide 27310B 3.INSPECT GENERATOR DRIVE END FRAME BEARING

a.
A156418

When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.

If necessary, replace the generator drive end frame bearing.


Hide 4.INSPECT GENERATOR ROTOR BEARING

a.
A163064

When rotating the bearing, check that there is no abnormal noise and that it rotates smoothly.

If necessary, replace the generator rotor assembly.