Home › Vehicle Interior › AIR CONDITIONING › AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)
RM27M0U _58 Vehicle Interior _049154 AIR CONDITIONING _0234411 AIR CONDITIONING SYSTEM(for Manual Air Conditioning System) C

AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)  B1412/12  Ambient Temperature Sensor Circuit  


DESCRIPTION

The ambient temperature sensor is installed in front of the condenser to detect the ambient temperature. This sensor is connected to the air conditioning amplifier and detects fluctuations in the ambient temperature. This data is used for controlling the cabin temperature. The sensor sends a signal to the air conditioning amplifier. The resistance of the ambient temperature sensor changes in accordance with the ambient temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier applies voltage (5 V) to the ambient temperature sensor and reads voltage changes as the resistance of the ambient temperature sensor changes.

DTC Code DTC Detection Condition Trouble Area
B1412/12 Open or short in ambient temperature sensor circuit
·

Ambient temperature sensor

·

Harness or connector between ambient temperature sensor and air conditioning amplifier

·

Air conditioning amplifier



WIRING DIAGRAM

E344814E03
4.542,1.115 4.75,1.313 0.208,0.198 10 false 5 2.396,1.104 2.552,1.302 0.156,0.198 10 false 1 2.385,1.969 2.542,2.167 0.156,0.198 10 false 2 4.521,1.979 4.729,2.177 0.208,0.198 10 false 13 4.896,1.208 5.25,1.406 0.354,0.198 10 false TAM 4.896,2.094 5.271,2.292 0.375,0.198 10 false SG-2 0.5,2.656 0.781,2.854 0.281,0.198 10 false A15 0.49,2.844 2.229,3.073 1.74,0.229 10 false Ambient Temperature Sensor 5.01,2.656 5.292,2.854 0.281,0.198 10 false J19 5.01,2.833 6.594,3.063 1.583,0.229 10 false Air Conditioning Amplifier

PROCEDURE

1.READ VALUE USING TECHSTREAM (AMBIENT TEMPERATURE SENSOR)
a.

Use the Data List to check if the ambient temperature sensor is functioning properly.

Air Conditioner
Tester Display Measurement Item / Range Normal Condition Diagnostic Note
Ambient Temp Sensor Ambient temperature sensor /
Min.: -23.3°C (-9.94°F)
Max.: 65.95°C (150.71°F)
Actual ambient temperature is displayed Open in circuit: -23.3°C (-9.94°F)
Short in circuit: 65.95°C (150.71°F)

OK:

The display is as specified in the normal condition.


Result
Result Proceed to
NG A
OK (Checking from the PROBLEM SYMPTOMS TABLE) B
OK (Checking from the DTC) C



A

2.INSPECT AMBIENT TEMPERATURE SENSOR

B

PROCEED TO NEXT CIRCUIT INSPECTION SHOWN IN PROBLEM SYMPTOMS TABLE

C

REPLACE AIR CONDITIONING AMPLIFIER

2.INSPECT AMBIENT TEMPERATURE SENSOR
E344817E01
2.719,1.708 2.25,0.969 false 0.188,0.094 2.615,0.438 2.427,0.344 10 false Component without harness connected: (Ambient Temperature Sensor) 1.448,0.844 2.396,1.073 0.948,0.229 10 false Sensor Area 4.167,0.021 5.25,0.25 1.083,0.229 10 false Resistance (kΩ) 4.313,0.302 4.583,0.49 0.271,0.188 10 false 4.0 4.313,0.521 4.583,0.708 0.271,0.188 10 false 3.5 4.302,0.74 4.573,0.927 0.271,0.188 10 false 3.0 4.292,0.969 4.563,1.156 0.271,0.188 10 false 2.5 4.292,1.208 4.563,1.396 0.271,0.188 10 false 2.0 4.292,1.448 4.563,1.635 0.271,0.188 10 false 1.5 4.292,1.688 4.563,1.875 0.271,0.188 10 false 1.0 4.292,1.917 4.563,2.104 0.271,0.188 10 false 0.5 4.292,2.135 4.563,2.323 0.271,0.188 10 false 0.0 4.531,2.198 4.75,2.385 0.219,0.188 10 false 10 4.49,2.333 4.74,2.531 0.25,0.198 10 false (50) 4.969,2.198 5.188,2.385 0.219,0.188 10 false 20 5.427,2.198 5.646,2.385 0.219,0.188 10 false 30 5.906,2.198 6.125,2.385 0.219,0.188 10 false 40 6.375,2.198 6.594,2.385 0.219,0.188 10 false 50 6.844,2.198 7.063,2.385 0.219,0.188 10 false 60 4.927,2.333 5.177,2.531 0.25,0.198 10 false (68) 5.385,2.323 5.635,2.521 0.25,0.198 10 false (86) 5.854,2.333 6.167,2.531 0.313,0.198 10 false (104) 6.281,2.323 6.594,2.521 0.313,0.198 10 false (122) 6.75,2.323 7.063,2.521 0.313,0.198 10 false (140) 5.042,2.615 6.323,2.792 1.281,0.177 10 false Temperature °C (°F)

a.

Remove the ambient temperature sensor (see page Vehicle Interior>AIR CONDITIONING>AMBIENT TEMPERATURE SENSOR>REMOVAL).


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).




OK

3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

NG

REPLACE AMBIENT TEMPERATURE SENSOR

3.CHECK HARNESS AND CONNECTOR (AMBIENT TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E344818E01
0.448,1.531 0.813,1.76 0.365,0.229 0.729,3.875 1.094,4.104 0.365,0.229 1.479,4.281 1.813,3.958 false 2.656,4.24 2.302,3.958 false 0.563,0.042 2.833,0.406 2.271,0.365 10 false Front view of wire harness connector: (to Ambient Temperature Sensor) 0.573,2.26 2.844,2.625 2.271,0.365 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier) 0.521,1.563 0.885,1.781 0.365,0.219 10 false A15 0.802,3.906 1.167,4.125 0.365,0.219 10 false J19 1.219,4.313 1.583,4.531 0.365,0.219 10 false SG-2 2.542,4.292 2.906,4.51 0.365,0.219 10 false TAM

a.

Disconnect the A15 sensor connector.


b.

Disconnect the J19 air conditioning amplifier connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
A15-1 - J19-5 (TAM) Always Below 1 Ω
A15-2 - J19-13 (SG-2)
A15-1 or J19-5 (TAM) - Body ground Always 10 kΩ or higher
A15-2 or J19-13 (SG-2) - Body ground




OK

REPLACE AIR CONDITIONING AMPLIFIER

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR