The No. 1 cooler thermistor is installed on the evaporator in the air conditioner unit to detect the cooled air temperature that has passed through the evaporator and control the air conditioning. It sends appropriate signals to the air conditioning amplifier. The resistance of the No. 1 cooler thermistor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1413/13 | Open or short in evaporator temperature sensor circuit | ·
No. 1 cooler thermistor ·
Air conditioning harness ·
Air conditioning amplifier |
Use the Data List to check if the No. 1 cooler thermistor is functioning properly.
| Tester Display | Measurement Item / Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Fin Thermistor | No. 1 cooler thermistor /
Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual No. 1 cooler thermistor is displayed | Open in circuit: -29.7°C (-21.46°F)
Short in circuit: 59.55°C (139.19°F) |
The display is as specified in the normal condition.
| Result | Proceed to |
|---|---|
| NG | A |
| OK (Checking from the PROBLEM SYMPTOMS TABLE) | B |
| OK (Checking from the DTC) | C |
A
B
C
Remove the No. 1 cooler thermistor connector (see page Vehicle Interior>AIR CONDITIONING>FRONT EVAPORATOR TEMPERATURE SENSOR>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 1 - 2 | -10°C (14°F) | 7.30 to 9.10 kΩ |
| -5°C (23°F) | 5.65 to 6.95 kΩ | |
| 0°C (32°F) | 4.40 to 5.35 kΩ | |
| 5°C (41°F) | 3.40 to 4.15 kΩ | |
| 10°C (50°F) | 2.70 to 3.25 kΩ | |
| 15°C (59°F) | 2.14 to 2.58 kΩ | |
| 20°C (68°F) | 1.71 to 2.05 kΩ | |
| 25°C (77°F) | 1.38 to 1.64 kΩ | |
| 30°C (86°F) | 1.11 to 1.32 kΩ |
Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.
When measuring, the sensor temperature must be the same as the ambient temperature.
As the temperature increases, the resistance decreases (see the graph).
OK
NG
Repair or replace the air conditioning harness.
NEXT
Check for DTC (see page Vehicle Interior>AIR CONDITIONING>AIR CONDITIONING SYSTEM(for Manual Air Conditioning System)>DTC CHECK / CLEAR).
DTC is not output.
OK
NG