AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System)  B1411/11  Room Temperature Sensor Circuit  


DESCRIPTION

The room temperature sensor is installed in the instrument panel to detect the room temperature and control the heater and air conditioner "AUTO" mode. The resistance of the room temperature sensor changes in accordance with the room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier.

DTC Code DTC Detection Condition Trouble Area
B1411/11 Open or short in room temperature sensor circuit
·

Room temperature sensor

·

Harness or connector between room temperature sensor and air conditioning amplifier

·

Air conditioning amplifier



WIRING DIAGRAM

E344814E01
4.479,1.094 4.688,1.292 0.208,0.198 10 false 29 2.396,1.104 2.552,1.302 0.156,0.198 10 false 1 2.385,1.969 2.542,2.167 0.156,0.198 10 false 2 4.49,1.969 4.698,2.167 0.208,0.198 10 false 34 4.896,1.208 5.146,1.406 0.25,0.198 10 false TR 4.896,2.094 5.271,2.292 0.375,0.198 10 false SG-1 0.5,2.656 0.781,2.854 0.281,0.198 10 false J16 0.49,2.844 2.229,3.073 1.74,0.229 10 false Room Temperature Sensor 5.01,2.656 5.292,2.854 0.281,0.198 10 false J19 5.01,2.833 6.594,3.063 1.583,0.229 10 false Air Conditioning Amplifier

PROCEDURE

1.READ VALUE USING TECHSTREAM (ROOM TEMPERATURE SENSOR)
a.

Use the Data List to check if the room temperature sensor is functioning properly.

Air Conditioner
Tester Display Measurement Item / Range Normal Condition Diagnostic Note
Room Temperature Sensor Room temperature sensor /
Min.: -6.5°C (20.3°F)
Max.: 57.25°C (135.05°F)
Actual room temperature is displayed Open in circuit: -6.5°C (20.3°F)
Short in circuit: 57.25°C (135.05°F)

OK:

The display is as specified in the normal condition.


Result
Result Proceed to
NG A
OK (Checking from the PROBLEM SYMPTOMS TABLE) B
OK (Checking from the DTC) C



A

2.INSPECT ROOM TEMPERATURE SENSOR

B

C

REPLACE AIR CONDITIONING AMPLIFIER

2.INSPECT ROOM TEMPERATURE SENSOR
E344815E01
1.813,1.979 2.51,2.188 2.51,2.188 2.51,2.313 false 1.771,1.281 2.188,0.865 false 1.635,1.292 1.25,0.896 false 0.427,0.042 2.854,0.406 2.427,0.365 10 false Component without harness connected: (Room Temperature Sensor) 2.25,0.698 2.438,0.885 0.188,0.188 10 false 1 1.125,0.719 1.313,0.906 0.188,0.188 10 false 2 2.125,2.313 2.958,2.51 0.833,0.198 10 false Sensor Area 4.344,0.01 5.396,0.229 1.052,0.219 10 false Resistance (kΩ) 5.333,2.49 6.615,2.708 1.281,0.219 10 false Temperature °C (°F) 4.302,0.302 4.552,0.49 0.25,0.188 10 false 4.0 4.292,0.542 4.542,0.729 0.25,0.188 10 false 3.5 4.292,0.979 4.542,1.167 0.25,0.188 10 false 2.5 4.281,1.198 4.531,1.385 0.25,0.188 10 false 2.0 4.281,1.417 4.531,1.604 0.25,0.188 10 false 1.5 4.281,1.656 4.531,1.844 0.25,0.188 10 false 1.0 4.281,1.896 4.531,2.083 0.25,0.188 10 false 0.5 4.292,2.125 4.542,2.313 0.25,0.188 10 false 0.0 4.51,2.198 4.76,2.385 0.25,0.188 10 false 10 4.927,2.198 5.177,2.385 0.25,0.188 10 false 20 4.292,0.771 4.542,0.958 0.25,0.188 10 false 3.0 5.385,2.198 5.635,2.385 0.25,0.188 10 false 30 5.823,2.198 6.073,2.385 0.25,0.188 10 false 40 6.271,2.198 6.521,2.385 0.25,0.188 10 false 50 6.729,2.198 6.979,2.385 0.25,0.188 10 false 60 4.479,2.333 4.76,2.531 0.281,0.198 10 false (50) 4.885,2.333 5.167,2.531 0.281,0.198 10 false (68) 5.344,2.323 5.625,2.521 0.281,0.198 10 false (86) 5.75,2.323 6.083,2.521 0.333,0.198 10 false (104) 6.177,2.323 6.5,2.531 0.323,0.208 10 false (122) 6.646,2.323 6.969,2.531 0.323,0.208 10 false (140)


b.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Even slightly touching the sensor may change the resistance value. Be sure to hold the connector of the sensor.

·

When measuring, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).




OK

3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)

NG

3.CHECK HARNESS AND CONNECTOR (ROOM TEMPERATURE SENSOR - AIR CONDITIONING AMPLIFIER)
E344816E01
0.604,1.458 0.917,1.677 0.313,0.219 0.698,3.854 1.01,4.073 0.313,0.219 2.344,4.333 2.021,4.073 false 1.406,4.344 1.719,4.083 false 0.667,2.281 2.938,2.625 2.271,0.344 10 false Rear view of wire harness connector: (to Air Conditioning Amplifier) 0.594,0.063 2.865,0.406 2.271,0.344 10 false Front view of wire harness connector: (to Room Temperature Sensor) 0.656,1.479 0.99,1.677 0.333,0.198 10 false J16 0.74,3.875 1.073,4.073 0.333,0.198 10 false J19 1.115,4.354 1.448,4.552 0.333,0.198 10 false SG-1 2.417,4.344 2.75,4.542 0.333,0.198 10 false TR

a.

Disconnect the J16 sensor connector.


b.

Disconnect the J19 air conditioning amplifier connector.


c.

Measure the resistance according to the value(s) in the table below.

Standard resistance:
Tester Connection Condition Specified Condition
J16-1 - J19-29 (TR) Always Below 1 Ω
J16-2 - J19-34 (SG-1)
J16-1 or J19-29 (TR) - Body ground Always 10 kΩ or higher
J16-2 or J19-34 (SG-1) - Body ground




OK

REPLACE AIR CONDITIONING AMPLIFIER

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR