Home › Vehicle Interior › AIR CONDITIONING › AMBIENT TEMPERATURE SENSOR
RM27M0U _58 Vehicle Interior _049154 AIR CONDITIONING _0234418 AMBIENT TEMPERATURE SENSOR G

AIR CONDITIONING  AMBIENT TEMPERATURE SENSOR  INSPECTION  


PROCEDURE

Hide 88625P 1.INSPECT COOLER (AMBIENT TEMPERATURE SENSOR) THERMISTOR

E344975E01
2.729,0.323 3.031,0.729 false 0.104,0.031 0.417,0.229 0.313,0.198 10 false *a 2.531,0.208 2.844,0.406 0.313,0.198 10 false *1 0.177,1.615 0.49,1.813 0.313,0.198 10 false *b 1.823,4.448 2.135,4.646 0.313,0.198 10 false *c 0.208,1.885 0.521,2.083 0.313,0.198 10 false 4.0 0.208,2.135 0.521,2.333 0.313,0.198 10 false 3.5 0.208,2.406 0.521,2.604 0.313,0.198 10 false 3.0 0.219,2.667 0.531,2.865 0.313,0.198 10 false 2.5 0.219,2.938 0.531,3.135 0.313,0.198 10 false 2.0 0.208,3.208 0.521,3.406 0.313,0.198 10 false 1.5 0.219,3.479 0.531,3.677 0.313,0.198 10 false 1.0 0.208,3.76 0.521,3.958 0.313,0.198 10 false 0.5 0.219,3.979 0.531,4.177 0.313,0.198 10 false 0.0 0.469,4.135 0.781,4.333 0.313,0.198 10 false 10 0.958,4.125 1.271,4.323 0.313,0.198 10 false 20 1.5,4.125 1.813,4.323 0.313,0.198 10 false 30 2.042,4.125 2.354,4.323 0.313,0.198 10 false 40 2.594,4.125 2.906,4.323 0.313,0.198 10 false 50 3.094,4.125 3.313,4.323 0.219,0.198 10 false 60 0.49,4.281 0.802,4.479 0.313,0.198 10 false 50 0.958,4.271 1.271,4.448 0.313,0.177 10 false 68 1.51,4.271 1.823,4.448 0.313,0.177 10 false 86 2.021,4.26 2.333,4.438 0.313,0.177 10 false 104 2.563,4.26 2.875,4.438 0.313,0.177 10 false 122 3.052,4.26 3.365,4.438 0.313,0.177 10 false 140

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
15°C (59°F) 2.45 to 2.88 kΩ
20°C (68°F) 1.95 to 2.30 kΩ
25°C (77°F) 1.60 to 1.80 kΩ
30°C (86°F) 1.28 to 1.47 kΩ
35°C (95°F) 1.00 to 1.22 kΩ
40°C (104°F) 0.80 to 1.00 kΩ
45°C (113°F) 0.65 to 0.85 kΩ
50°C (122°F) 0.50 to 0.70 kΩ
55°C (131°F) 0.44 to 0.60 kΩ
60°C (140°F) 0.36 to 0.50 kΩ


NOTICE:
·

Touching the sensor even slightly may change the resistance value. Hold the connector of the sensor.


·

When measuring the resistance, the sensor temperature must be the same as the ambient temperature.



HINT:

As the temperature increases, the resistance decreases (see the graph).


Text in Illustration
*1 Sensor Area
*a Component without harness connected
(Cooler (Ambient Temperature Sensor) Thermistor)
*b Resistance (kΩ)
*c Temperature (°C (°F))

If the result is not as specified, replace the cooler (ambient temperature sensor) thermistor.