Each unit of the navigation system connected to the AVC-LAN (communication bus) transfers the switch signals using the AVC-LAN.
If a short to +B or short to ground occurs in the AVC-LAN, the navigation system will not function normally because communication is not possible.
The navigation receiver assembly is the master unit.
for Column Shift Type:
Remove the navigation receiver assembly with the connector(s) still connected (See page Audio / Visual / Telematics>NAVIGATION / MULTI INFO DISPLAY>NAVIGATION RECEIVER(for Column Shift Type)>REMOVAL).
for Floor Shift Type:
Remove the navigation receiver assembly with the connector(s) still connected (See page Audio / Visual / Telematics>NAVIGATION / MULTI INFO DISPLAY>NAVIGATION RECEIVER(for Floor Shift Type)>REMOVAL).
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 7 (TX1+) - 8 (TX1-) | Always | 60 to 80 Ω |
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for Column Shift Type) | B |
| NG (for Floor Shift Type) | C |
A
B
C
Disconnect the J135 navigation receiver assembly connector.
Disconnect the J141 stereo component amplifier assembly connector.
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| J141-8 (TX+) - J135-7 (TX1+) | Always | Below 1 Ω |
| J141-7 (TX-) - J135-8 (TX1-) | Always | Below 1 Ω |
| J141-8 (TX+) - Body ground | Always | 10 kΩ or higher |
| J141-7 (TX-) - Body ground | Always | 10 kΩ or higher |
OK
NG
Disconnect and reconnect each slave unit one by one until the master unit returns to normal operation.
Check all slave units.
If disconnecting a slave unit causes the master unit to return to normal operation, the slave unit is defective and should be replaced.
Master unit returns to normal operation.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (for Column Shift Type) | B |
| NG (for Floor Shift Type) | C |
A
B
C