Home › Power Source / Network › M15A-FKS (BATTERY / CHARGING) › GENERATOR (for 80A Type)
RM3700E _57 Power Source / Network _092979 M15A-FKS BATTERY / CHARGING _0438221 GENERATOR(for 80A Type) G

M15A-FKS BATTERY / CHARGING  GENERATOR(for 80A Type)  ON-VEHICLE INSPECTION  


CAUTION / NOTICE / HINT

NOTICE:
·

Do not remove the generator pulley cap.

·

If the generator pulley cap is removed, replace the generator pulley cap and generator pulley with clutch with new ones as the correct grease amount cannot be confirmed.



HINT:

If it is confirmed that the generator assembly is not generating power, it is not necessary to perform the counterclockwise check as another malfunction is suspected.


PROCEDURE

Hide 1.REMOVE V-RIBBED BELT

Hide 27415 2.INSPECT GENERATOR WITH CLUTCH PULLEY

a.
A406402C01
0,0 0,0 false
V100135

Counterclockwise
V100136

Clockwise


Check that the generator pulley with clutch operates in accordance with the following table.

Standard:
Counterclockwise Clockwise
Lock* Lock


HINT:
·

*:Rotates when a torque exceeding a certain value is applied.

·

If the generator pulley with clutch does not turn smoothly, does not operate as specified, or an abnormal sound is output, replace it with a new one.




Hide 3.INSTALL V-RIBBED BELT