| *A | for Automatic Air Conditioning System | *B | for Manual Air Conditioning System |
87138C
1.INSTALL BLOWER RESISTOR (for Manual Air Conditioning System)
87139C
2.INSTALL CLEAN AIR FILTER
|
|
88899M
3.INSTALL AIR FILTER COVER PLATE
|
|
87103B
4.INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY
87130K
5.INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)
| *a | Link | - | - |
Connect the link of the No. 1 blower damper servo sub-assembly to the groove on the lever of the blower assembly as shown in the illustration.
Install the No. 1 blower damper servo sub-assembly with the 2 screws.
55908A
6.INSTALL AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System)
for Single Layer Type:
Set the cable gear and unit gear to the recirculation position.
Engage the claws to install the air inlet damper control cable sub-assembly.
| *a | Recirculation | - | - |
Set the cable gear and unit gear to the recirculation position.
Engage the claws to install the air inlet damper control cable sub-assembly.