Home › Power Source / Network › POWER DISTRIBUTION › INTEGRATION RELAY › 2020.08–2021.07
RM3700E _57 Power Source / Network _093028 POWER DISTRIBUTION _0438534 INTEGRATION RELAY A

POWER DISTRIBUTION  INTEGRATION RELAY  INSTALLATION  


CAUTION / NOTICE / HINT

COMPONENTS (INSTALLATION)
E448354N01
1.552,1.271 1.885,1.271 false 1.729,0.583 2.063,0.583 false 6.406,0.281 6.792,0.281 false 6.417,0.771 6.75,0.771 false 2.188,1.115 2.469,1.469 0.281,0.354 18 false 1 2.125,0.438 2.406,0.792 0.281,0.354 18 false 2 6.24,0.656 6.583,1.01 0.344,0.354 18 false 4 6.219,0.146 6.5,0.5 0.281,0.354 18 false 3

Procedure Part Name Code
Z101186

Z101188

Z101187

1 SEMICONDUCTOR POWER INTEGRATION ECU 82644 (Click here) - -
2 NO. 1 RELAY BLOCK COVER 82662A - - -
3 NEGATIVE AUXILIARY BATTERY TERMINAL - - - -
4 INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL - - - (Click here)

PROCEDURE

Hide 82644 1.INSTALL SEMICONDUCTOR POWER INTEGRATION ECU

Z101186

NOTICE:
·

Make sure the connector terminal is free from oil and grease.

·

Do not subject the semiconductor power integration ECU to any impact.

·

Do not use a semiconductor power integration ECU that has been dropped.

·

Do not disassemble the semiconductor power integration ECU.

·

Make sure the lever connector is securely connected.




Hide 82662A 2.INSTALL NO. 1 RELAY BLOCK COVER

Hide 3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL

Hide 4. INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART