HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for Gasoline Model with Automatic Air Conditioning System)  B143B7F  Air Inlet Damper Control Servo Motor Actuator Stuck Off  


DESCRIPTION

The No. 1 blower damper servo sub-assembly sends pulse signals to inform the air conditioning amplifier assembly of the damper position. The air conditioning amplifier assembly activates the motor (normal or reverse) based on these signals to move the air inlet damper to the appropriate position, which controls the air inlet switching.

The air conditioning amplifier assembly communicates with the servo through a communication/driver IC and wiring assembly called the air conditioning harness assembly.

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority
B143B7F Air Inlet Damper Control Servo Motor Actuator Stuck Off Diagnosis Condition:

No. 1 blower damper servo sub-assembly operating


Malfunction Status:

Damper servo operation request signals are output but the damper position sensor value does not change or abnormal


Detection Time:

Continuously for 30 seconds or more


·

No. 1 blower damper servo sub-assembly

·

Air conditioning harness assembly

·

Air conditioning radiator assembly


Memorized Air Conditioner A

DTC Detection Condition Combination Table
Vehicle Condition
Pattern 1 Pattern 2
Diagnosis Condition No. 1 blower damper servo sub-assembly operating ○ ○
Malfunction Damper servo operation request signals are output but the damper position sensor value does not change ○ -
Damper servo operation request signals are output but the damper position sensor value is abnormal - ○
Detection Time Continuously for 30 seconds or more Continuously for 30 seconds or more
Trip Count 1 trip 1 trip

HINT:

If the conditions of either of these patterns are detected, a DTC will be stored


WIRING DIAGRAM

E437384E01
2.292,1.823 2.656,2.01 0.365,0.188 10 false IC 5.521,6.688 6.083,6.885 0.563,0.198 10 false h6 5.51,6.865 7.073,7.188 1.563,0.323 10 false Air Conditioning Amplifier Assembly 3.104,6.771 5.448,7.177 2.344,0.406 10 false Air Conditioning Harness Assembly 0.219,6.979 3.177,7.333 2.958,0.354 10 false No. 1 Blower Damper Servo Sub-assembly 0.156,4.844 2.938,5.177 2.781,0.333 10 false No. 1 Air Conditioning Radiator Damper Servo Sub-assembly 0.729,3.5 1.427,3.781 0.698,0.281 10 false Mode 0.656,1.5 1.271,1.729 0.615,0.229 10 false Air Mix 5.542,1.677 6.104,1.875 0.563,0.198 10 false BUSG 5.542,1.104 6.104,1.302 0.563,0.198 10 false BUS 5.542,0.5 6.104,0.698 0.563,0.198 10 false BUSB 6.76,1.198 7,1.396 0.24,0.198 10 false IC 5.354,0.49 5.656,0.698 0.302,0.208 10 false 4 5.354,1.042 5.656,1.25 0.302,0.208 10 false 3 5.354,1.677 5.656,1.885 0.302,0.208 10 false 2 0.781,7.469 3.083,7.844 2.302,0.375 10 false : LIN Communication Line 6.448,0.323 6.771,0.51 0.323,0.188 10 false +B 2.594,2.781 3.208,2.979 0.615,0.198 10 false STE2 2.594,2.99 3.208,3.188 0.615,0.198 10 false STE1 2.75,3.188 3.365,3.385 0.615,0.198 10 false M- 2.646,5.573 3.26,5.771 0.615,0.198 10 false GND 2.74,5.781 3.354,5.979 0.615,0.198 10 false M+ 2.75,5.979 3.365,6.177 0.615,0.198 10 false M- 2.656,6.156 3.271,6.354 0.615,0.198 10 false sigA 2.667,6.365 3.281,6.563 0.615,0.198 10 false sigB 3.031,2.677 3.333,2.885 0.302,0.208 10 false 3 3.031,2.885 3.333,3.094 0.302,0.208 10 false 4 3.031,3.094 3.333,3.302 0.302,0.208 10 false 1 3.031,3.667 3.333,3.875 0.302,0.208 10 false 2 3.031,3.875 3.333,4.083 0.302,0.208 10 false 5 3.031,5.552 3.333,5.76 0.302,0.208 10 false 1 3.031,5.771 3.333,5.979 0.302,0.208 10 false 4 3.042,5.969 3.344,6.177 0.302,0.208 10 false 5 3.042,6.167 3.344,6.375 0.302,0.208 10 false 2 3.042,6.365 3.344,6.573 0.302,0.208 10 false 3 2.729,3.677 3.344,3.875 0.615,0.198 10 false M+ 2.646,3.875 3.26,4.073 0.615,0.198 10 false GND 0.167,4.677 0.781,4.875 0.615,0.198 10 false h7 0.24,6.781 0.854,6.979 0.615,0.198 10 false h4 2.646,1.76 3,1.958 0.354,0.198 10 false GND 2.719,1.177 3.073,1.375 0.354,0.198 10 false LIN 2.76,0.594 3.031,0.802 0.271,0.208 10 false +B 3.021,1.042 3.24,1.26 0.219,0.219 10 false 7 3.021,0.479 3.219,0.635 0.198,0.156 10 false 8 3.031,1.677 3.24,1.865 0.208,0.188 10 false 6

CAUTION / NOTICE / HINT

NOTICE:
·

This DTC is also output for the damper link, damper lock, etc. Before performing inspection, perform servomotor initialization and check that there are no mechanical malfunctions.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System)>INITIALIZATION

·

This DTC is also output when servomotor initialization has failed. When servomotor initialization has failed, repair any malfunctions and perform servomotor initialization again.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for Gasoline Model with Automatic Air Conditioning System)>INITIALIZATION



PROCEDURE

1.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Air Conditioner > Trouble Codes
50001 450

Result:
Result Proceed to
B14037F, B14067F and B143B7F are output A
Only B143B7F is output B



A

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

B

2.PERFORM ACTIVE TEST USING GTS
2.PERFORM ACTIVE TEST USING GTS
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Air Inlet Damper Control Servo Motor No. 1 blower damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Air Inlet Damper Control Servo Motor
50004 450 32

Result:
Result Proceed to
No. 1 air conditioning radiator damper servo sub-assembly operates A
No. 1 air conditioning radiator damper servo sub-assembly does not operate at all B



A

3.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

B

REPLACE NO. 1 AIR CONDITIONING RADIATOR DAMPER SERVO SUB-ASSEMBLY

3.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
a.

Check that the No. 1 blower damper servo sub-assembly is installed correctly.

HINT:

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>REASSEMBLY


OK:

The No. 1 blower damper servo sub-assembly is installed correctly.



Result:
Proceed to
OK
NG



OK

4.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)

NG

INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

4.CHECK NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (MOTOR, LINK, DAMPER)
a.

Check for a wire harness caught between the links of the motors and dampers.

OK:

No wire harnesses are caught between the links of the motors and dampers.



Result:
Proceed to
OK
NG



OK

5.CHECK BLOWER ASSEMBLY

NG

REMOVE PINCHED WIRE HARNESS

5.CHECK BLOWER ASSEMBLY

Pre-procedure1

a.

Remove the No. 1 blower damper servo sub-assembly.

HINT:

Click hereVehicle Interior>HEATING / AIR CONDITIONING>BLOWER UNIT>DISASSEMBLY



Procedure1

a.

Operate the air inlet dampers by hand.

OK:

The air inlet dampers are easily operated by hand.


Result:
Proceed to
OK
NG



Post-procedure1

a.

None



OK

6.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

NG

6.INSPECT AIR CONDITIONING HARNESS ASSEMBLY

Pre-procedure1

a.

Disconnect the h7 No. 1 air conditioning radiator damper servo sub-assembly connector.


Procedure1

a.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(h7,h4)Location & Routing

Click Connector(h7)Instrument Panel>Air Conditioning Harness>No. 1 Air Conditioning Radiator Damper Servo Sub-Assembly

Click Connector(h4)Instrument Panel>Air Conditioning Harness>No. 1 Blower Damper Servo Sub-Assembly

h7-1 (M-) - h4-5 (M-) Always Below 1 Ω
h7-2 (M+) - h4-4 (M+) Always Below 1 Ω
h7-3 (STE2) - h4-3 (sigB) Always Below 1 Ω
h7-4 (STE1) - h4-2 (sigA) Always Below 1 Ω
h7-5 (GND) - h4-1 (GND) Always Below 1 Ω
h7-1 (M-) or h4-5 (M-) - Other terminals and body ground Always 10 kΩ or higher
h7-2 (M+) or h4-4 (M+) - Other terminals and body ground Always 10 kΩ or higher
h7-3 (STE2) or h4-3 (sigB) - Other terminals and body ground Always 10 kΩ or higher
h7-4 (STE1) or h4-2 (sigA) - Other terminals and body ground Always 10 kΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

None



OK

REPLACE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY

NG

REPAIR OR REPLACE AIR CONDITIONING HARNESS ASSEMBLY