Home › Vehicle Exterior › EXTERIOR PANELS / TRIM › ROOF DRIP SIDE FINISH MOULDING › 2020.08–2021.07
RM3700E _59 Vehicle Exterior _093282 EXTERIOR PANELS / TRIM _0440170 ROOF DRIP SIDE FINISH MOULDING A

EXTERIOR PANELS / TRIM  ROOF DRIP SIDE FINISH MOULDING  INSTALLATION  


CAUTION / NOTICE / HINT

COMPONENTS (INSTALLATION)
B591001N02
5,0.792 5.354,0.792 false 2.875,1.49 3.188,1.49 false 2.906,0.333 3.073,0.333 3.073,0.333 3.323,0.719 false 5.823,0.635 6.104,0.99 0.281,0.354 18 false 1 2.719,0.167 3,0.521 0.281,0.354 18 false 2 3.698,1.281 3.979,1.635 0.281,0.354 18 false 1 3.521,1.365 3.677,1.563 0.156,0.198 10 false ● 5.646,0.719 5.802,0.917 0.156,0.198 10 false ●

Procedure Part Name Code
Z101186

Z101188

Z101187

1 NO.1 ROOF DRIP SIDE FINISH MOULDING CLIP 75561A (Click here) - -
2 ROOF DRIP SIDE FINISH MOULDING 75552E - - -

● Non-reusable part - -

CAUTION / NOTICE / HINT

HINT:
·

Use the same procedure for the RH side and LH side.

·

The following procedure is for the LH side.



PROCEDURE

Hide 75561A 1.INSTALL NO. 1 ROOF DRIP SIDE FINISH MOULDING CLIP

Z101186

NOTICE:

When installing new No. 1 roof drip side finish moulding clips, remove any double-sided tape remaining where the No. 1 roof drip side finish moulding clips will be installed on the vehicle body and clean the vehicle body with a non-residue solvent.



a.
B591002C02
2.729,0.729 3.146,0.896 true 4.354,0.438 4.771,0.604 false 2.385,0.156 2.667,0.51 0.281,0.354 18 false i 0.906,1.5 1.188,1.854 0.281,0.354 18 false ii 2.5,0.615 2.708,0.802 0.208,0.188 10 false *b 4.802,0.615 5.01,0.802 0.208,0.188 10 false *a
*a Adhesive *b 2 to 3 mm Bead of Adhesive
V100144

Primer Application - -


i.

Apply a 2 to 3 mm (0.0787 to 0.118 in.) bead of adhesive (3M DP-105 or equivalent) to each new roof drip side finish moulding clip.

HINT:

Adhesive strength (tensile strength): 13.7 Mpa (140.0 kgf/cm2, 1987 psi) or more (when the temperature is 23°C (73°F).)



ii.

Apply primer to the vehicle body where the roof drip side finish moulding clip will be installed.

NOTICE:

Do not let the primer dry.




b.
B591003C02
1.448,1.021 1.604,1.219 0.156,0.198 10 false A 3.01,1.021 3.167,1.219 0.156,0.198 10 false B 4.708,1.594 4.865,1.792 0.156,0.198 10 false C 5.885,2.406 6.042,2.604 0.156,0.198 10 false D 6.115,0.229 6.396,0.583 0.281,0.354 18 false i 5.729,0.844 5.938,1.031 0.208,0.188 10 true *a 4.906,1.344 5.115,1.51 0.208,0.167 10 true *b 1.958,2.094 2.167,2.281 0.208,0.188 10 true *a 2.958,2.271 3.167,2.438 0.208,0.167 10 true *b 0.854,0.177 1.063,0.365 0.208,0.188 10 false *a 2.24,0.177 2.448,0.344 0.208,0.167 10 false *b 5.594,1.604 5.802,1.771 0.208,0.167 10 false *b 4.146,1.583 4.354,1.771 0.208,0.188 10 false *a
*a View A *b View B


i.

Install the No. 1 roof drip side finish moulding clips to the positions on the roof panel shown in the illustration. Determine the locations and firmly press and install the No. 1 roof drip side finish moulding clips.

HINT:
·

Install the roof drip side finish moulding when 40 minutes or more have elapsed since the roof drip side finish moulding clips were installed.

·

Initial hardening time: 40 minutes

·

Complete hardening time: 24 hours



Standard Measurement:
Area Measurement Area Measurement
A 5.9 to 6.9 mm (0.232 to 0.272 in.) B 4.2 mm (0.165 in.)
C 5.7 to 6.7 mm (0.224 to 0.264 in.) D 4.0 mm (0.157 in.)




Hide 75552E 2.INSTALL ROOF DRIP SIDE FINISH MOULDING