Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › MOTOR GENERATOR CONTROL SYSTEM
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0441184 MOTOR GENERATOR CONTROL SYSTEM C

HYBRID / BATTERY CONTROL  MOTOR GENERATOR CONTROL SYSTEM  P0BE528  Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure  P0BE928  Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure  P0BED28  Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure  


DTC SUMMARY

MALFUNCTION DESCRIPTION


These DTCs indicate that the current sensor value is abnormal. The cause of this malfunction may be one of the following:


Internal inverter malfunction
·

Current sensor malfunction

·

Hybrid motor control inverter assembly internal circuit malfunction


DESCRIPTION

The motor generator control ECU (MG ECU), which is built into the hybrid motor control inverter assembly, monitors the motor inverter current sensor. These DTCs indicate the malfunction of current sensors and do not indicate a malfunction of the high-voltage system.

DTC No. Detection Item DTC Detection Condition Trouble Area MIL Warning Indicate DTC Output from Priority
P0BE528 Drive Motor "A" Phase U Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Motor inverter current sensor U phase offset malfunction:
The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the motor inverter is shutdown.
(1 trip detection logic)
·

Hybrid motor control inverter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
Motor Generator A
P0BE928 Drive Motor "A" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Motor inverter current sensor V phase offset malfunction:
The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the motor inverter is shutdown.
(1 trip detection logic)
·

Hybrid motor control inverter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
Motor Generator A
P0BED28 Drive Motor "A" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Motor inverter current sensor W phase offset malfunction:
The absolute value of the current sensor output exceeds the threshold when current should not flow, such as when the motor inverter is shutdown.
(1 trip detection logic)
·

Hybrid motor control inverter assembly

·

Wire harness or connector


Comes on Master Warning:
Comes on
Motor Generator A

CONFIRMATION DRIVING PATTERN

HINT:

After repair has been completed, clear the DTC and then check that the vehicle has returned to normal by performing the following All Readiness check procedure.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>UTILITY


1.

Clear the DTCs (even if no DTCs are stored, perform the clear DTC procedure).

2.

Turn the ignition switch off and wait for 2 minutes or more.

3.

Turn the ignition switch to ON and wait for 5 seconds or more.

4.

Turn the ignition switch to ON (READY) with the shift lever in P and wait for 5 seconds or more.

5.

Enter the following menus: Powertrain / Motor Generator / Utility / All Readiness.

6.

Check the DTC judgment result.

HINT:
·

If the judgment result shows NORMAL, the system is normal.

·

If the judgment result shows ABNORMAL, the system has a malfunction.

·

If the judgment result shows INCOMPLETE or N/A, perform driving pattern again.




CAUTION / NOTICE / HINT

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*

-

Disconnecting the low voltage connector of the HV battery


*: for AWD


·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.

·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

·
A357589C56
1.573,0.74 2.021,0.427 true 2.094,0.344 2.354,0.51 0.26,0.167 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.


*: for AWD




NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




PROCEDURE

1.CHECK DTC OUTPUT

Pre-procedure1

a.

None.


Procedure1

a.

Check for DTCs.

Powertrain > Hybrid Control > Trouble Codes
50001 397
Powertrain > Motor Generator > Trouble Codes
50001 395
Powertrain > Rear Motor Generator > Trouble Codes
50001 396
Result:
Result Proceed to
Only P0BE528, P0BE928 or P0BED28 for Motor generator control system is output A
P0BE528, P0BE928 or P0BED28 is output and DTCs other than the DTCs in the table below are output B
P0BE528, P0BE928 or P0BED28 is output and Insulation Malfunction of Hybrid control system DTCs in the table below are output C
P0BE528, P0BE928 or P0BED28 is output and High voltage circuit malfunction of Hybrid control system DTCs in the table below are output D
P0BE528, P0BE928 or P0BED28 is output and Microcomputer malfunction of Hybrid control system DTCs in the table below are output E
P0BE528, P0BE928 or P0BED28 is output and Microcomputer malfunction of Motor generator control system DTCs in the table below are output F
P0BE528, P0BE928 or P0BED28 is output and Power source circuit malfunction of Motor generator control system DTCs in the table below are output G
P0BE528, P0BE928 or P0BED28 is output and Power source circuit malfunction of Rear motor generator control system DTCs in the table below are output H
P0BE528, P0BE928 or P0BED28 is output and Communication malfunction of Motor generator control system DTCs in the table below are output I
P0BE528, P0BE928 or P0BED28 is output and Sensor and actuator circuit malfunction of Motor generator control system DTCs in the table below are output J
P0BE528, P0BE928 or P0BED28 is output and System malfunction of Motor generator control system DTCs in the table below are output K


Table 1
Malfunction Content System Relevant DTC
Insulation Malfunction Hybrid control system P1C7C49 Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure
P1C7D49 Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure
P1C7E49 Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure
P1C7F49 Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure
P1C8049 Hybrid/EV Battery Voltage System Isolation (Rear Motor Area) Internal Electronic Failure
High voltage circuit malfunction Hybrid control system P0AA649 Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure

Table 2
Malfunction Content System Relevant DTC
Microcomputer malfunction Hybrid control system P0A1B49 Drive Motor "A" Control Module Internal Electronic Failure
Motor generator control system P1C2B1C Drive Motor "A" Control Module A/D Converter Circuit Voltage Out of Range
P1C2B49 Drive Motor "A" Control Module A/D Converter Circuit Internal Electronic Failure
Power source circuit malfunction Motor generator control system P06B01C Generator Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
P06D61C Generator Control Module Offset Power Circuit Voltage Out of Range
Rear motor generator control system P262C1C Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range
Communication malfunction Motor generator control system P312487 Lost Communication between Drive Motor "A" and HV ECU Missing Message
Sensor and actuator circuit malfunction Motor generator control system P0A3F16 Drive Motor "A" Position Sensor Circuit Voltage Below Threshold
P0A3F21 Drive Motor "A" Position Sensor Signal Amplitude < Minimum
P0A3F22 Drive Motor "A" Position Sensor Signal Amplitude > Maximum
P0C5013 Drive Motor "A" Position Sensor Circuit "A" Circuit Open
P0C5016 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Below Threshold
P0C5017 Drive Motor "A" Position Sensor Circuit "A" Circuit Voltage Above Threshold
P0C5A13 Drive Motor "A" Position Sensor Circuit "B" Circuit Open
P0C5A16 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Below Threshold
P0C5A17 Drive Motor "A" Position Sensor Circuit "B" Circuit Voltage Above Threshold
P0D2D16 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Below Threshold
P0D2D17 Drive Motor "A" Inverter Voltage Sensor (VH) Circuit Voltage Above Threshold
P1CAD49 Drive Motor "A" Position Sensor Internal Electronic Failure
P1CB038 Drive Motor "A" Position Sensor REF Signal Frequency Incorrect
System malfunction Motor generator control system P0A7873 Drive Motor "A" Inverter Actuator Stuck Closed

HINT:
·

P0BE528, P0BE928 or P0BED28 may be output as a result of the malfunction indicated by the DTCs above.

(a)

The chart above is listed in inspection order of priority.

(b)

Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)





Post-procedure1

a.

Turn the ignition switch off.



A

2.CHECK CONNECTOR CONNECTION CONDITION (HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

B

2.CHECK CONNECTOR CONNECTION CONDITION (HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

C

D

E

F

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

G

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

H

I

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

J

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

K

GO TO DTC CHART (MOTOR GENERATOR CONTROL SYSTEM)

2.CHECK CONNECTOR CONNECTION CONDITION (HYBRID MOTOR CONTROL INVERTER ASSEMBLY CONNECTOR)

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>P033500

Result:
Result Proceed to
OK A
NG (The connector is not connected securely.) B
NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C



A

REPLACE HYBRID MOTOR CONTROL INVERTER ASSEMBLY

B

CONNECT SECURELY

C

REPAIR OR REPLACE HARNESS OR CONNECTOR