| P06B31C
|
Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A1C1F
|
Drive Motor "B" Control Module Circuit Intermittent
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A4516
|
Drive Motor "B" Position Sensor Circuit Voltage Below Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A451F
|
Drive Motor "B" Position Sensor Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P0A4521
|
Drive Motor "B" Position Sensor Signal Amplitude < Minimum
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A4522
|
Drive Motor "B" Position Sensor Signal Amplitude > Maximum
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A6912
|
Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A6914
|
Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A691C
|
Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A691F
|
Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P0A6C12
|
Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A6C14
|
Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A6C1C
|
Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0A6C1F
|
Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P0A799E
|
Drive Motor "B" Inverter Stuck On
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0AF211
|
Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0AF215
|
Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0AF21F
|
Drive Motor Inverter Temperature Sensor "B" Circuit Intermittent
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BD111
|
Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Short to Ground
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BD115
|
Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Short to Battery or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BD11F
|
Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Intermittent
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BF512
|
Drive Motor "B" Phase V Current Sensor Circuit Short to Battery
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BF514
|
Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BF51F
|
Drive Motor "B" Phase V Current Sensor Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P0BF528
|
Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BF912
|
Drive Motor "B" Phase W Current Sensor Circuit Short to Battery
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BF914
|
Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0BF91F
|
Drive Motor "B" Phase W Current Sensor Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P0BF928
|
Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C021D
|
Drive Motor "B" System Circuit Current Out of Range
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C1A00
|
Drive Motor "B" Execution Torque Performance
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C3100
|
Drive Motor Inverter Temperature Sensor "C" Circuit
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C5513
|
Drive Motor "B" Position Sensor Circuit "A" Circuit Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C5516
|
Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C5517
|
Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C551F
|
Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P0C5F13
|
Drive Motor "B" Position Sensor Circuit "B" Circuit Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C5F16
|
Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C5F17
|
Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0C5F1F
|
Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P0C7A17
|
Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0DA316
|
Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0DA317
|
Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P0DA31F
|
Drive Motor "B" Inverter Voltage Sensor "A" Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P1C2C1C
|
Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P1C2C49
|
Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P1C5E19
|
Drive Motor "B" Inverter Circuit Current Above Threshold
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P1C611F
|
Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P1C631F
|
Drive Motor "B" Control Module Offset Power Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P1C661F
|
Drive Motor "B" Control Module Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P1CAE49
|
Drive Motor "B" Position Sensor Internal Electronic Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P1CB138
|
Drive Motor "B" Position Sensor REF Signal Frequency Incorrect
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P1CE49E
|
Drive Motor "B" Inverter Voltage Sensor "A" Stuck On
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P262C1C
|
Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P310462
|
Drive Motor Inverter Temperature Sensor "B" Signal Compare Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P31491F
|
Lost Communication between Drive Motor "A" and "B" Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P314987
|
Lost Communication between Drive Motor "A" and "B" Missing Message
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P31E41F
|
Drive Motor "B" Phase V Current Sensor Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P31E51F
|
Drive Motor "B" Phase W Current Sensor Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P33C012
|
Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Battery
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P33C014
|
Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Ground or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P33C01F
|
Drive Motor "B" Phase V Current Sensor Sub Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P33C028
|
Drive Motor "B" Phase V Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P33C512
|
Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Battery
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P33C514
|
Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Ground or Open
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P33C51F
|
Drive Motor "B" Phase W Current Sensor Sub Circuit Intermittent
|
Does not come on
|
Master Warning:
Does not come on
|
Rear Motor Generator
|
A
|
|
| P33C528
|
Drive Motor "B" Phase W Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P33D862
|
Drive Motor "B" Phase V Current Sensor Signal Compare Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|
| P33D962
|
Drive Motor "B" Phase W Current Sensor Signal Compare Failure
|
Does not come on
|
Master Warning:
Comes on
|
Rear Motor Generator
|
A
|
|