Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › REAR MOTOR GENERATOR CONTROL SYSTEM
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0442914 REAR MOTOR GENERATOR CONTROL SYSTEM S

HYBRID / BATTERY CONTROL  REAR MOTOR GENERATOR CONTROL SYSTEM  DIAGNOSTIC TROUBLE CODE CHART  


Rear Motor Generator Control System
DTC No. Detection Item MIL Warning Indicate DTC Output from Priority Link
P06B31C Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Voltage Out of Range Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A1C1F Drive Motor "B" Control Module Circuit Intermittent Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A4516 Drive Motor "B" Position Sensor Circuit Voltage Below Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A451F Drive Motor "B" Position Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P0A4521 Drive Motor "B" Position Sensor Signal Amplitude < Minimum Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A4522 Drive Motor "B" Position Sensor Signal Amplitude > Maximum Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A6912 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Battery Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A6914 Drive Motor "B" Phase V Current(High Resolution) Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A691C Drive Motor "B" Phase V Current(High Resolution) Circuit Voltage Out of Range Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A691F Drive Motor "B" Phase V Current(High Resolution) Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P0A6C12 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Battery Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A6C14 Drive Motor "B" Phase W Current(High Resolution) Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A6C1C Drive Motor "B" Phase W Current(High Resolution) Circuit Voltage Out of Range Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0A6C1F Drive Motor "B" Phase W Current(High Resolution) Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P0A799E Drive Motor "B" Inverter Stuck On Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0AF211 Drive Motor Inverter Temperature Sensor "B" Circuit Short to Ground Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0AF215 Drive Motor Inverter Temperature Sensor "B" Circuit Short to Battery or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0AF21F Drive Motor Inverter Temperature Sensor "B" Circuit Intermittent Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BD111 Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Short to Ground Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BD115 Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Short to Battery or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BD11F Drive Motor Inverter Temperature Sensor "C" Circuit Circuit Intermittent Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BF512 Drive Motor "B" Phase V Current Sensor Circuit Short to Battery Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BF514 Drive Motor "B" Phase V Current Sensor Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BF51F Drive Motor "B" Phase V Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P0BF528 Drive Motor "B" Phase V Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BF912 Drive Motor "B" Phase W Current Sensor Circuit Short to Battery Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BF914 Drive Motor "B" Phase W Current Sensor Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0BF91F Drive Motor "B" Phase W Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P0BF928 Drive Motor "B" Phase W Current Sensor Signal Bias Level Out of Range / Zero Adjustment Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C021D Drive Motor "B" System Circuit Current Out of Range Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C1A00 Drive Motor "B" Execution Torque Performance Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C3100 Drive Motor Inverter Temperature Sensor "C" Circuit Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C5513 Drive Motor "B" Position Sensor Circuit "A" Circuit Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C5516 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Below Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C5517 Drive Motor "B" Position Sensor Circuit "A" Circuit Voltage Above Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C551F Drive Motor "B" Position Sensor Circuit "A" Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P0C5F13 Drive Motor "B" Position Sensor Circuit "B" Circuit Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C5F16 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Below Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C5F17 Drive Motor "B" Position Sensor Circuit "B" Circuit Voltage Above Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0C5F1F Drive Motor "B" Position Sensor Circuit "B" Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P0C7A17 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0DA316 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Below Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0DA317 Drive Motor "B" Inverter Voltage Sensor "A" Circuit Voltage Above Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P0DA31F Drive Motor "B" Inverter Voltage Sensor "A" Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P1C2C1C Drive Motor "B" Control Module AD Converter Circuit Voltage Out of Range Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P1C2C49 Drive Motor "B" Control Module AD Converter Circuit Internal Electronic Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P1C5E19 Drive Motor "B" Inverter Circuit Current Above Threshold Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P1C611F Drive Motor "B" Control Module Position Sensor REF Power Source Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P1C631F Drive Motor "B" Control Module Offset Power Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P1C661F Drive Motor "B" Control Module Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P1CAE49 Drive Motor "B" Position Sensor Internal Electronic Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P1CB138 Drive Motor "B" Position Sensor REF Signal Frequency Incorrect Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P1CE49E Drive Motor "B" Inverter Voltage Sensor "A" Stuck On Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P262C1C Drive Motor "B" Control Module Offset Power Circuit Voltage Out of Range Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P310462 Drive Motor Inverter Temperature Sensor "B" Signal Compare Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P31491F Lost Communication between Drive Motor "A" and "B" Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P314987 Lost Communication between Drive Motor "A" and "B" Missing Message Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P31E41F Drive Motor "B" Phase V Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P31E51F Drive Motor "B" Phase W Current Sensor Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P33C012 Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Battery Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P33C014 Drive Motor "B" Phase V Current Sensor Sub Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P33C01F Drive Motor "B" Phase V Current Sensor Sub Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P33C028 Drive Motor "B" Phase V Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P33C512 Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Battery Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P33C514 Drive Motor "B" Phase W Current Sensor Sub Circuit Short to Ground or Open Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P33C51F Drive Motor "B" Phase W Current Sensor Sub Circuit Intermittent Does not come on Master Warning:
Does not come on
Rear Motor Generator A Click here
P33C528 Drive Motor "B" Phase W Current Sensor Sub Signal Bias Level Out of Range / Zero Adjustment Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P33D862 Drive Motor "B" Phase V Current Sensor Signal Compare Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here
P33D962 Drive Motor "B" Phase W Current Sensor Signal Compare Failure Does not come on Master Warning:
Comes on
Rear Motor Generator A Click here