The DC/DC converter converts the DC 177.6 V of the HV battery into DC 12 V in order to supply power to areas such as the vehicle lighting system, audio system and various ECUs. Additionally, it charges the auxiliary battery.
A transistor bridge circuit initially converts DC 177.6 V into alternating current, and a transformer lowers the voltage.
The DC/DC converter controls the output voltage in order to keep a constant voltage at the terminals of the auxiliary battery.
Then, it is rectified and smoothed (into direct current) and converted into DC 12 V.
The motor generator control ECU sends a signal to the DC/DC converter to prohibit its control and receives signals indicating a normal or abnormal condition of the 12 V charging system via the NODD signal line.
If the DC/DC converter malfunctions, the vehicle will become inoperative. Therefore, the motor generator control ECU monitors the operation of the DC/DC converter and detects malfunctions.
This DTC is stored when the DC/DC converter circuit has a malfunction or its operation is prohibited by a fail-safe function, or the auxiliary battery voltage drops to 11 V or less with the ignition switch ON (READY).
If a DC/DC converter malfunction occurs, DC/DC converter malfunction signals are sent from the DC/DC converter to the MG ECU via the NODD signal line.
This DTC may also be stored if a malfunction of the inverter cooling system (blockage, water pump malfunction, etc.) or a high-voltage insulation malfunction occurs.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | MIL | Warning Indicate | DTC Output from | Priority |
|---|---|---|---|---|---|---|---|
| P1CCC96 | DC/DC Converter Enable Component Internal Failure | Both of the following conditions are met:
·
The DC/DC converter is malfunctioning and the auxiliary battery voltage is 11 V or less.*1 ·
The inverter coolant temperature is 70 °C or lower for 60 seconds. (1 trip detection logic) |
·
Engine wire ·
Inverter cooling system ·
Cooling fan system ·
Hybrid motor control inverter assembly ·
Hybrid vehicle transaxle assembly ·
Motor cable ·
DC/DC fuse ·
Hybrid vehicle control ECU ·
Inverter water pump assembly ·
Wire harness or connector |
Does not come on | Master Warning:
Comes on |
Motor Generator | A |
*1: If the DC/DC converter is malfunctioning, its operation and charging will be stopped and the auxiliary battery voltage will drop.
Refer to the wiring diagram for the Generator High-voltage Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Generator High-voltage Circuit
Refer to the wiring diagram for the Motor High-voltage Circuit.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor High-voltage Circuit
Refer to the wiring diagram for the Cooling System.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Cooling System
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
Disconnecting the low voltage connector of the HV battery
*: for AWD
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>MOTOR GENERATOR CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
After repair, clear the DTCs, turn the ignition switch off and wait for 30 seconds or more and perform the following procedure to confirm that the auxiliary battery low voltage indicated by this DTC has been repaired.
Wait for 2 minutes with the shift lever in P, the ignition switch ON (READY) and the following conditions met, then confirm that Data List item "BATT Voltage (Hybrid control system)" is between 13.0 and 15.0 V.
(If charging is not performed and the electrical load increases, +B voltage may not be steady and will gradually drop.)
Headlight switch is in the HI position.
A/C blower fan switch is in the HI position.
Window defogger switch is turned on.
By performing the following procedure, the DC/DC converter function can be checked.
Connect the AC/DC 400 A probe to the positive (+) auxiliary battery cable.
Turn the ignition switch to ON (READY) and leave the vehicle as is until the electric current flowing to the auxiliary battery becomes 10 A or less.
Turn the ignition switch to ON (READY) and turn the headlight switch and A/C blower fan switch to the HI position and the window defogger on.
Confirm that the current drawn from the auxiliary battery is 0 A or lower and the auxiliary battery voltage is between 12.5 and 15.0 V.
This DTC may be also stored when a part other than the DC/DC converter is malfunctioning or depending on user operation.
If this vehicle is used to jump start another vehicle with a discharged battery, a fuse may blow due to overcurrent or the DC/DC converter self-protection may be activated. Also, if this vehicle is jump started by a vehicle with a 24 V battery, the same malfunction may occur and this DTC may be stored. (The suspended DC/DC converter control will return to normal by clearing the DTCs and turning the ignition switch off.)
Confirm that high electrical load equipment such as a high-capacitance audio device or electric kettle is used in the vehicle. (A fuse of the auxiliary battery may be blown due to overcurrent.)
If the DC/DC converter is malfunctioning, the auxiliary battery cannot be charged. Therefore, once the ignition switch is turned off, it may be impossible to turn it to ON (READY) again if the auxiliary battery is completely discharged. In this case, charge the auxiliary battery. Be careful as charging is not performed during the inspection.
If the ignition switch turns off immediately after it is turned to ON (READY), the auxiliary battery voltage may be low. Charge the auxiliary battery.
Pre-procedure1
None.
Procedure1
Check for DTCs.
| Result | Proceed to |
|---|---|
| Only P1CCC96 for Motor generator control system is output | A |
| P1CCC96 and DTCs other than the DTCs in the table below are output | B |
| P1CCC96 and Insulation Malfunction of Hybrid control system DTCs in the table below are output | C |
| P1CCC96 and High Voltage Circuit Malfunction of Hybrid control system DTCs in the table below are output | D |
| P1CCC96 and System malfunction of Hybrid control system DTCs in the table below are output | E |
| P1CCC96 and System malfunction of Hybrid control system DTCs in the table below are output | F |
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| Insulation Malfunction | Hybrid control system | P1C7C49 | Hybrid/EV Battery Voltage System Isolation (A/C Area) Internal Electronic Failure |
| P1C7D49 | Hybrid/EV Battery Voltage System Isolation (Hybrid/EV Battery Area) Internal Electronic Failure | ||
| P1C7E49 | Hybrid/EV Battery Voltage System Isolation (Transaxle Area) Internal Electronic Failure | ||
| P1C7F49 | Hybrid/EV Battery Voltage System Isolation (Direct Current Area) Internal Electronic Failure | ||
| High Voltage Circuit Malfunction | Hybrid control system | P0AA649 | Hybrid/EV Battery Voltage System Isolation Internal Electronic Failure |
| P0AD911 | Hybrid/EV Battery Positive Contactor Circuit Short to Ground | ||
| P0ADD11 | Hybrid/EV Battery Negative Contactor Circuit Short to Ground | ||
| P0AE411 | Hybrid/EV Battery Precharge Contactor Circuit Short to Ground | ||
| P1C8449 | High Voltage Power Resource Circuit Short during Ready ON | ||
| P300449 | High Voltage Power Resource Circuit Short during Pre-Charge | ||
| Malfunction Content | System | Relevant DTC | |
|---|---|---|---|
| System malfunction | Motor generator control system | P0E5717 | DC/DC Converter Voltage Sensor "A" (VL) Circuit Voltage Above Threshold |
| Hybrid control system | P0A9300 | Inverter "A" Cooling System Performance | |
| P0C7396 | Motor Electronics Coolant Pump "A" Component Internal Failure | ||
| P314A31 | Motor Electronics Coolant Pump "A" No Signal | ||
P1CCC96 may be output as a result of the malfunction indicated by the DTCs above.
The chart above is listed in inspection order of priority.
Check DTCs that are output at the same time by following the listed order. (The main cause of the malfunction can be determined without performing unnecessary inspections.)
Post-procedure1
Turn the ignition switch off.
A
B
C
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
D
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
E
F
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>DIAGNOSTIC TROUBLE CODE CHART
Be sure to wear insulated gloves.
Pre-procedure1
Connect the cable to the negative (-) auxiliary battery terminal.
Procedure1
| *a | 2B-1 (AMD) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2B-1 (AMD) - Body ground | Ignition switch off | Same as auxiliary battery voltage |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Procedure1
| *1 | AMD Terminal
(Hybrid Motor Control Inverter Assembly Side) |
| *2 | AMD Terminal
(No. 1 Engine Room Relay Block Side) |
Check that the bolts for the AMD terminal are tightened to the specified torque, the AMD terminal is connected securely, and there are no contact problems.
Hybrid Motor Control Inverter Assembly Side:
T=10 N*m (102 kgf*cm, 7 ft.*lbf)
No. 1 Engine Room Relay Block Side:
T=10 N*m (102 kgf*cm, 7 ft.*lbf)
| Result | Proceed to | |
|---|---|---|
| There are no arc marks. | The terminal is connected securely and there are no contact problems. | A |
| There are no arc marks. | The terminal is not connected securely and there is a contact problem. | B |
| There are arc marks. | - | C |
Post-procedure1
None.
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the engine wire from the AMD terminal (hybrid motor control inverter assembly side and No. 1 engine room relay block side).
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(D61)Location & Routingewd_type=routing;type=c;code=D61 Click Connector(D61)Engine Compartment>Engine Wire>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=D61;pinno=1 |
||
| D61-1 (AMD) - 2B-1 (AMD) | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the engine wire.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Cooling System
| Proceed to |
|---|
| NEXT |
NEXT
The current at the AMD terminal cannot be measured directly because of space limitations. Measure the current flowing at the auxiliary battery instead.
Pre-procedure1
Connect the AC/DC 400 A probe of the tester to the positive (+) auxiliary battery cable.
Install the service plug grip.
Connect the cable to the negative (-) auxiliary battery terminal.
| *a | Probe Direction |
| *b | Current Flowing to Auxiliary Battery |
Turn the ignition switch to ON (READY) and leave the vehicle as it is until the electric current flowing to the auxiliary battery becomes 10 A or less.
If the ignition switch turns off immediately after it is turned to ON (READY), auxiliary battery voltage may be low. Recharge the auxiliary battery and perform this procedure again.
Procedure1
| *a | Probe Direction |
| *b | Current Flowing from Auxiliary Battery |
Measure the current flowing from the auxiliary battery with the ignition switch to ON (READY), the headlight position switch and blower motor switch in the HI position, and the rear window defogger turned on.
| Item | Condition | Specified Condition |
|---|---|---|
| Current flowing from auxiliary battery | Ignition switch ON (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) |
0 A or less
(no current from auxiliary battery) |
Measure the voltage according to the value(s) in the table below.
| Item | Condition | Specified Condition |
|---|---|---|
| Auxiliary battery voltage | Ignition switch ON (READY)
(The headlight position switch and blower motor switch are in the HI position, and the rear window defogger is turned on.) |
12.5 to 15 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
OK
NG
Pre-procedure1
Disconnect the cable from the negative (-) auxiliary battery terminal.
| *1 | No. 1 Engine Room Relay Block |
| *2 | DC/DC fuse |
Remove the DC/DC fuse from No. 1 engine room relay block.
Procedure1
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| DC/DC fuse | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter cover from the hybrid motor control inverter assembly.
Procedure1
Using a megohmmeter set to 500 V, measure the insulation resistance according to the value(s) in the table below.
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(k2)Location & Routingewd_type=routing;type=c;code=k2 Click Connector(k2)Engine Compartment>Motor Cable>Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=k2;pinno=1,2,3,4,5,6 |
||
| k2-1 (W) - Body ground and shield ground | Ignition switch off | 1 MΩ or higher |
| k2-2 (U) - Body ground and shield ground | Ignition switch off | 1 MΩ or higher |
| k2-3 (V) - Body ground and shield ground | Ignition switch off | 1 MΩ or higher |
| k2-4 (W) - Body ground and shield ground | Ignition switch off | 1 MΩ or higher |
| k2-5 (U) - Body ground and shield ground | Ignition switch off | 1 MΩ or higher |
| k2-6 (V) - Body ground and shield ground | Ignition switch off | 1 MΩ or higher |
Perform this inspection while the motor cable are connected.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Install the inverter cover to the hybrid motor control inverter assembly.
OK
NG
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Generator High-voltage Circuit
| Proceed to |
|---|
| NEXT |
NEXT
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>Motor High-voltage Circuit
| Proceed to |
|---|
| NEXT |
NEXT