Home › Engine / Hybrid System › HYBRID / BATTERY CONTROL › HYBRID CONTROL SYSTEM
RM3700E _51 Engine / Hybrid System _093506 HYBRID / BATTERY CONTROL _0441183 HYBRID CONTROL SYSTEM J

HYBRID / BATTERY CONTROL  HYBRID CONTROL SYSTEM  Generator High-voltage Circuit  


DESCRIPTION

The cause of this malfunction may be the generator high-voltage circuit.

Check the generator internal resistance and the connection condition of the high-voltage line between the inverter and generator to check whether there is an open or short circuit.

Related Parts Check
Area Inspection
Motor cable (for MG1) connection check Check for the connection condition of the cable from the inverter to the generator.
Generator or motor cable (for MG1) Check the generator (including cable) internal resistance and the insulation resistance with body ground to check for an open or short circuit.

WIRING DIAGRAM

A452397E12
1.188,2.406 3.021,2.646 1.833,0.24 10 false : High Voltage Line 2.427,0.438 2.75,0.698 0.323,0.26 10 false W 2.458,0.781 2.615,0.979 0.156,0.198 10 false U 2.458,1.135 2.615,1.333 0.156,0.198 10 false V 2.667,0.406 2.823,0.604 0.156,0.198 10 false 4 2.667,0.76 2.823,0.958 0.156,0.198 10 false 5 2.656,1.115 2.813,1.313 0.156,0.198 10 false 6 1.146,1.583 2.198,1.75 1.052,0.167 10 false k1 1.146,1.781 3.375,2.177 2.229,0.396 10 false Hybrid Vehicle Transaxle Assembly (Generator (MG1)) 4.927,0.417 5.083,0.615 0.156,0.198 10 false 4 4.927,0.76 5.083,0.958 0.156,0.198 10 false 5 4.927,1.104 5.083,1.302 0.156,0.198 10 false 6 4.615,1.583 4.979,1.781 0.365,0.198 10 false k2 4.625,1.792 7.104,1.979 2.479,0.188 10 false Hybrid Motor Control Inverter Assembly 5.104,0.531 5.375,0.729 0.271,0.198 10 false W 5.115,0.885 5.271,1.083 0.156,0.198 10 false U 5.115,1.24 5.271,1.438 0.156,0.198 10 false V

CAUTION / NOTICE / HINT

This diagnostic procedure is referenced to in the diagnostic procedure of several DTCs.

If the result of this diagnostic procedure is normal, proceed as directed in the procedure for the DTC.

CAUTION:
·
A340358

Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.

-

Inspecting the high-voltage system

-

Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*

*: for AWD

-

Disconnecting the low voltage connector of the HV battery



·
A357588

To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.


·
A358042

After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.


·
A357589C04
1.563,0.708 1.813,0.417 true 1.844,0.302 2.156,0.5 0.313,0.198 10 false *a
*a Without waiting for 10 minutes


After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.

Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION

HINT:

Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.


*: for AWD



NOTICE:
·

After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY

·

When disconnecting and reconnecting the auxiliary battery

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE

HINT:

When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.

Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART




PROCEDURE

1.CHECK HYBRID MOTOR CONTROL INVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the inverter cover from the hybrid motor control inverter assembly.


Procedure1

a.
A475589

Check that the bolts for the motor cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

Specified Condition:

T = 8.0 N*m (82 kgf*cm, 71 in.*lbf)



b.

Disconnect the motor cable from the hybrid motor control inverter assembly.


c.

Check for arc marks at the terminals for the motor cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



Post-procedure1

a.

Reconnect the motor cable.


b.

Reinstall the inverter cover.



A

2.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR (MG1))

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

2.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (GENERATOR (MG1))
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the inverter cover from the hybrid motor control inverter assembly.


c.

Disconnect the motor cable from the hybrid motor control inverter assembly.


Procedure1

a.
A377530C58
1.573,0.208 1.938,0.438 0.365,0.229 2.177,1.042 2.177,1.885 true 2.448,1.063 2.708,1.875 true 1.917,1.052 1.615,1.885 true 2.75,1.531 2.99,1.76 false 3.031,1.719 3.344,1.917 0.313,0.198 10 false *1 0.146,0.125 0.458,0.323 0.313,0.198 10 false *a 2.146,1.917 2.458,2.115 0.313,0.198 10 false U 2.698,1.917 3.01,2.115 0.313,0.198 10 false V 1.563,1.917 1.875,2.115 0.313,0.198 10 false W 1.698,0.25 2.01,0.448 0.313,0.198 10 false k2
*1 Shield Ground
*a Motor Cable (for MG1)
(Hybrid Motor Control Inverter Assembly Side)


Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

HINT:

If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.


Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(k2)Location & Routing

Click Connector(k2)Engine Compartment>Motor Cable>Hybrid Motor Control Inverter Assembly

k2-4 (W) - k2-5 (U) Ignition switch off 94.3 to 104.8 mΩ
k2-5 (U) - k2-6 (V) Ignition switch off 94.4 to 104.9 mΩ
k2-6 (V) - k2-4 (W) Ignition switch off 94.4 to 104.9 mΩ


HINT:

To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

R20 = Rt / {1 + 0.00393 X (T - 20)}

The calculation is based on the following:

R20: Resistance at 20°C (68°F) (mΩ)

Rt: Measured resistance (mΩ)

T: Temperature when the resistance is measured (°C)



b.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(k2)Location & Routing

Click Connector(k2)Engine Compartment>Motor Cable>Hybrid Motor Control Inverter Assembly

k2-4 (W) - Body ground and shield ground Ignition switch off 10 MΩ or higher
k2-5 (U) - Body ground and shield ground Ignition switch off 10 MΩ or higher
k2-6 (V) - Body ground and shield ground Ignition switch off 10 MΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Reconnect the motor cable.


b.

Reinstall the inverter cover.



OK

GENERATOR HIGH-VOLTAGE CIRCUIT NORMAL (PERFORM NEXT STEP FOR REFERENCED DTC)

NG

3.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
3.CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the hybrid motor control inverter assembly.


Procedure1

a.
A475647

Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

Specified Condition:

T=10 N*m (102 kgf*cm, 7 ft.*lbf)



b.

Disconnect the motor cable from the hybrid vehicle transaxle assembly.


c.

Check for arc marks at the terminals for the generator cable.

Result:
Result Proceed to
The terminals are connected securely and there are no contact problems. There are no arc marks. A
The terminals are not connected securely and there is a contact problem. There are arc marks. B
The terminals are not connected securely and there is a contact problem. There are no arc marks. C
The terminals are connected securely and there are no contact problems. There are arc marks. B



Post-procedure1

a.

Reconnect the motor cable.


b.

Reinstall the hybrid motor control inverter assembly.



A

4.CHECK MOTOR CABLE (FOR MG1)

B

REPLACE MALFUNCTIONING PARTS

C

CONNECT SECURELY

4.CHECK MOTOR CABLE (FOR MG1)
CAUTION:

Be sure to wear insulated gloves.


Pre-procedure1

a.

Check that the service plug grip is not installed.

NOTICE:

After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.



b.

Remove the hybrid motor control inverter assembly.


c.

Remove the motor cable.


Procedure1

a.

Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

A407602C31
1.719,0.625 2.094,0.875 0.375,0.25 5.094,0.625 5.469,0.875 0.375,0.25 2.979,1.979 3.094,2.219 true 2.115,1.458 1.938,2.188 true 2.375,1.458 2.323,2.177 true 2.646,1.458 2.76,2.156 true 5.938,1.24 6.104,2.135 true 5.698,1.24 5.719,2.115 true 5.427,1.24 5.229,2.115 true 6.542,1.521 6.656,1.76 true 0.177,0.156 0.49,0.354 0.313,0.198 10 false *a 1.833,0.677 2.146,0.875 0.313,0.198 10 false k2 5.229,0.677 5.542,0.875 0.313,0.198 10 false k1 3.167,2.167 3.479,2.365 0.313,0.198 10 false *1 1.875,2.229 2.188,2.427 0.313,0.198 10 false W 5.177,2.167 5.49,2.365 0.313,0.198 10 false W 2.292,2.229 2.604,2.427 0.313,0.198 10 false U 5.688,2.156 6,2.354 0.313,0.198 10 false U 2.729,2.229 3.042,2.427 0.313,0.198 10 false V 6.073,2.167 6.385,2.365 0.313,0.198 10 false V 6.74,1.719 7.052,1.917 0.313,0.198 10 false *1
*1 Shield Ground - -
*a Motor Cable - -


NOTICE:

Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.


Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(k2,k1)Location & Routing

Click Connector(k2)Engine Compartment>Motor Cable>Hybrid Motor Control Inverter Assembly

Click Connector(k1)Engine Compartment>Motor Cable>Hybrid Vehicle Transaxle Assembly

k2-4 (W) or k1-4 (W) - Shield ground Ignition switch off 10 MΩ or higher
k2-5 (U) or k1-5 (U) - Shield ground Ignition switch off 10 MΩ or higher
k2-6 (V) or k1-6 (V) - Shield ground Ignition switch off 10 MΩ or higher


NOTICE:

Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground.



b.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition

Click Location & Routing(k2,k1)Location & Routing

Click Connector(k2)Engine Compartment>Motor Cable>Hybrid Motor Control Inverter Assembly

Click Connector(k1)Engine Compartment>Motor Cable>Hybrid Vehicle Transaxle Assembly

k2-4 (W) - k1-4 (W) Ignition switch off Below 1 Ω
k2-5 (U) - k1-5 (U) Ignition switch off Below 1 Ω
k2-6 (V) - k1-6 (V) Ignition switch off Below 1 Ω
k2-4 (W) - k1-5 (U) Ignition switch off 10 MΩ or higher
k2-5 (U) - k1-6 (V) Ignition switch off 10 MΩ or higher
k2-6 (V) - k1-4 (W) Ignition switch off 10 MΩ or higher


Result:
Proceed to
OK
NG



Post-procedure1

a.

Install the motor cable.


b.

Reinstall the hybrid motor control inverter assembly.



OK

NG