Home › Engine / Hybrid System › M15A-FKS (ENGINE CONTROL) › CAMSHAFT OIL CONTROL SOLENOID (for Exhaust Side)
RM3700E _51 Engine / Hybrid System _093766 M15A-FKS ENGINE CONTROL _0442018 CAMSHAFT OIL CONTROL SOLENOID(for Exhaust Side) A

M15A-FKS ENGINE CONTROL  CAMSHAFT OIL CONTROL SOLENOID(for Exhaust Side)  REMOVAL  


CAUTION / NOTICE / HINT

COMPONENTS (REMOVAL)
A479403N01
2.917,1.615 2.469,1.156 2.469,1.156 2.354,1.156 false 2.375,3.927 2.042,3.927 false 2.292,1.865 2.458,1.865 false 2.135,1.042 2.427,1.448 0.292,0.406 18 false 2 2.563,1.854 2.865,2.042 0.302,0.188 10 false x2 2.458,3.781 2.75,4.188 0.292,0.406 18 false 1 1.333,4.344 1.635,4.531 0.302,0.188 10 false x2 2,1.792 2.406,1.979 0.406,0.188 10 false ●★

Procedure Part Name Code
Z101186

Z101188

Z101187

1 ENGINE WIRE - - - -
2 CAM TIMING OIL CONTROL SOLENOID ASSEMBLY 15370 (Click here) - -

● Non-reusable part ★ Precoated part

CAUTION / NOTICE / HINT

NOTICE:

This procedure includes the removal of small-head bolts. Refer to Small-Head Bolts of Basic Repair Hint to identify the small-head bolts.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION


PROCEDURE

Hide 1.DISCONNECT ENGINE WIRE

a.
A458035


Hide 15370 2.REMOVE CAM TIMING OIL CONTROL SOLENOID ASSEMBLY

a.
A458773N01
0.99,0.167 1.25,0.469 0.26,0.302 18 false iii 4.552,0.146 4.969,0.438 0.417,0.292 18 true i, ii

i.

Disconnect the cam timing oil control solenoid assembly connector.


ii.

Using an 8 mm socket wrench, remove the 2 bolts and cam timing oil control solenoid assembly from the No. 2 timing chain cover assembly.

NOTICE:

If the cam timing oil control solenoid assembly has been struck or dropped, replace it.



iii.

Remove the O-ring from the cam timing oil control solenoid assembly.

NOTICE:
·

When removing the O-ring, be careful not to damage the O-ring groove of the cam timing oil control solenoid assembly.

·

If the O-ring groove of the cam timing oil control solenoid assembly is damaged, replace the cam timing oil control solenoid assembly with a new one.



HINT:

Perform this procedure only when replacement of the O-ring is necessary.