PRECAUTIONS FOR INSPECTING HYBRID CONTROL SYSTEM
Before the following operations are conducted, take precautions to prevent electric shock by turning the ignition switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly
Disconnecting the low voltage connector of the HV battery
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
After removing the service plug grip, turning the ignition switch to ON (READY) may cause a malfunction. Do not turn the ignition switch to ON (READY) unless instructed by the repair manual.
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly.
Check the voltage at the terminals in the inspection point of the hybrid motor control inverter assembly.
Be sure to wear insulated gloves.
Remove the connector cover assembly from the hybrid motor control inverter assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>INVERTER WITH CONVERTER>REMOVAL
Do not touch the connector cover assembly waterproof seal.
Do not allow any foreign matter or water to enter the hybrid motor control inverter assembly.
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Inspection point | At least 10 minutes after removing the service plug grip | 0 V |
Make sure to set the tester to DC750 V or more when measuring the voltage.
Reinstall the connector cover assembly.
Check the voltage at the terminals in the inspection point of the rear hybrid motor control inverter assembly.
Wear insulated gloves.
| *a | Interlock Connector |
| *b | Waterproof Seal |
Remove the 5 bolts and inverter terminal cover from the rear hybrid motor control inverter assembly.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>REAR INVERTER>REMOVAL
Make sure to pull the connector cover assembly straight up, as a connector is connected to the bottom of the connector cover assembly.
Do not touch the connector cover assembly waterproof seal.
Do not allow any foreign matter or water to enter the rear hybrid motor control inverter assembly.
Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| Inspection point | At least 10 minutes after removing the service plug grip | 0 V |
Do not allow any foreign matter or water to enter the rear hybrid motor control inverter assembly.
As it may result in an incorrect measurement, do not use terminal (A) when measuring.
Make sure to set the tester to DC750 V or more when measuring the voltage.
w/ Entry and Start System:
When turning the power switch on (IG) during an inspection, do not press the power switch while depressing the brake pedal.
Pressing the power switch with the brake pedal depressed causes the system to enter the READY-on state. This is very dangerous because high voltage may be applied to the inspection area.
w/o Entry and Start System:
When turning the ignition switch to ON during inspections, do not turn the ignition switch to START.
Turning the ignition switch to START causes the system to enter the READY-on state. This is very dangerous because high voltage may be applied to the inspection area.
Turn the ignition switch off, disconnect the cable from the negative (-) terminal of the auxiliary battery and put on insulated gloves before touching any of the orange-colored wire harnesses and connectors of the high-voltage system.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
Turn the ignition switch off before performing any resistance checks.
Turn the ignition switch off before disconnecting or reconnecting any connectors.
When performing work involving high-voltage wires, use either a tool wrapped with vinyl insulating tape or an insulated tool.
When high-voltage connectors are removed, wrap the connectors with insulation tape to prevent them from contacting foreign matter.
NOTICE FOR HYBRID CONTROL SYSTEM ACTIVATION
When the warning is illuminated, or the auxiliary battery has been disconnected and reconnected, attempting to turn the ignition switch to ON (READY) may not start the system (the system may not enter the READY-on state) on the first attempt. If so, turn the ignition switch off and reattempt to start the hybrid system.
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART