The cause of this malfunction may be the rear motor resolver.
Check the rear motor resolver internal resistance and the connection condition from the rear inverter to the rear motor resolver.
| Area | Inspection |
|---|---|
| Wire harness and connector between the rear inverter and rear motor resolver | Check for short circuit between wire harness and +B side. |
| Resolver, wire harness, connector | Check the resolver internal resistance (include wire harness), body ground resistance, and connector connection condition. |
| Resolver | Check for open or short circuit in wire harness. |
The resolver is a sensor that is used to detect the position of the magnetic poles of the rotor of the rear motor. Knowing the position of the poles is indispensable for ensuring precise control of the rear motor. Each resolver contains a stator that has an excitation coil and 2 detection coils (S, C). The gap between the stator and rotor changes as the rotor turns because the rotor is oval shaped. An alternating current with a predetermined frequency flows through the excitation coil, and detection coils S and C output alternating currents in accordance with the sensor rotor position.
The rear motor generator control ECU (Rr MG ECU), which is built into the hybrid motor control rear inverter assembly, detects the absolute position of the rotor according to the phases of detection coils S and C and the heights of their waveforms. Furthermore, the CPU calculates the amount of change in the position within a predetermined length of time, in order to use the resolver as a revolution speed sensor.
The rear motor generator control ECU (Rr MG ECU), which is built into the hybrid motor control rear inverter assembly, monitors signals output from the rear motor resolver and detects malfunctions.
This step is referenced from the procedures for each DTC.
If the inspection results below are normal, perform the next procedure for the referenced DTC.
Before the following operations are conducted, take precautions to prevent electric shock by turning the power switch off, wearing insulated gloves, and removing the service plug grip from HV battery.
Inspecting the high-voltage system
Disconnecting the low voltage connector of the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*
*: for AWD
Disconnecting the low voltage connector of the HV battery
To prevent electric shock, make sure to remove the service plug grip to cut off the high voltage circuit before servicing the vehicle.
After removing the service plug grip from the HV battery, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
| *a | Without waiting for 10 minutes |
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*. The voltage should be 0 V before beginning work.
Click hereEngine / Hybrid System>HYBRID / BATTERY CONTROL>HYBRID CONTROL SYSTEM>PRECAUTION
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the hybrid motor control inverter assembly and rear hybrid motor control inverter assembly*.
*: for AWD
After the ignition switch is turned off, there may be a waiting time before disconnecting the auxiliary negative (-) battery terminal.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>BEFORE DISCONNECTING BATTERY
When disconnecting and reconnecting the auxiliary battery
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART
If the problem symptom cannot be reproduced, performing a road test on a road on which the vehicle tends to vibrate will make it easier to reproduce the symptom.
If the resolver is malfunctioning, the vehicle may not drive smoothly.
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the rear hybrid motor control inverter assembly connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON.
Procedure1
| *a | Front view of wire harness connector
(to Rear Hybrid Motor Control Inverter Assembly) |
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O75)Location & Routingewd_type=routing;type=c;code=O75 Click Connector(O75)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O75;pinno=1,6,4,9,5,10 |
||
| O75-1 (RRF) - Body ground | Ignition switch ON | Below 1 V |
| O75-6 (RRFG) - Body ground | Ignition switch ON | Below 1 V |
| O75-4 (RSN) - Body ground | Ignition switch ON | Below 1 V |
| O75-9 (RSNG) - Body ground | Ignition switch ON | Below 1 V |
| O75-5 (RCS) - Body ground | Ignition switch ON | Below 1 V |
| O75-10 (RCSG) - Body ground | Ignition switch ON | Below 1 V |
Turning the ignition switch to ON with the low voltage connector of the hybrid motor control inverter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Reconnect the hybrid motor control inverter assembly connector.
OK
NG
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the rear hybrid motor control inverter assembly connector.
Procedure1
| *a | Front view of wire harness connector
(to Rear Hybrid Motor Control Inverter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O75)Location & Routingewd_type=routing;type=c;code=O75 Click Connector(O75)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O75;pinno=1,6,4,9,5,10 |
||
| O75-1 (RRF) - O75-6 (RRFG) | Ignition switch off | 9.1 to 15.0 Ω |
| O75-4 (RSN) - O75-9 (RSNG) | Ignition switch off | 16.4 to 28.3 Ω |
| O75-5 (RCS) - O75-10 (RCSG) | Ignition switch off | 18.4 to 30.2 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(O75)Location & Routingewd_type=routing;type=c;code=O75 Click Connector(O75)Body>Floor Wire>Rear Hybrid Motor Control Inverter Assemblyewd_type=component;type=c;code=O75;pinno=1,6,4,9,5,10 |
||
| O75-1 (RRF) or O75-6 (RRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| O75-4 (RSN) or O75-9 (RSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| O75-5 (RCS) or O75-10 (RCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the rear hybrid motor control inverter assembly connector.
OK
NG
Check the connection condition of the rear motor resolver connector (floor wire connector) and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Be sure to wear insulated gloves.
Pre-procedure1
Check that the service plug grip is not installed.
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the floor wire connector.
Procedure1
| *a | Front view of floor wire connector
(to Floor Wire) |
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(UO1)Location & Routingewd_type=routing;type=w;code=UO1 Click Connector(UO1)Body>No. 6 Floor Wire>No. 6 Floor Wire and Floor Wireewd_type=component;type=w;code=UO1;pinno=6,5,4,13,12,11 |
||
| UO1-6 (RRF) - UO1-5 (RRFG) | Ignition switch off | 8.8 to 14.7 Ω |
| UO1-4 (RSN) - UO1-13 (RSNG) | Ignition switch off | 16.1 to 27.9 Ω |
| UO1-12 (RCS) - UO1-11 (RCSG) | Ignition switch off | 18.1 to 29.9 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(UO1)Location & Routingewd_type=routing;type=w;code=UO1 Click Connector(UO1)Body>No. 6 Floor Wire>No. 6 Floor Wire and Floor Wireewd_type=component;type=w;code=UO1;pinno=6,5,4,13,12,11 |
||
| UO1-6 (RRF) or UO1-5 (RRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| UO1-4 (RSN) or UO1-13 (RSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| UO1-12 (RCS) or UO1-11 (RCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the floor wire connector.
OK
NG
Check the connection condition of the rear motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter.
- The connector is connected securely.
- The terminals are not deformed and are connected securely.
- No water or foreign matter in the connector.
| Result | Proceed to |
|---|---|
| OK | A |
| NG (The connector is not connected securely.) | B |
| NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) | C |
A
B
C
Pre-procedure1
Disconnect the floor wire connector.
Procedure1
Measure the resistance according to the value(s) in the table below.
| *a | Front view of wire harness connector (floor wire)
(to floor wire) |
*b | Front view of wire harness connector (floor wire)
(to rear traction motor) |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(UO1,U1)Location & Routingewd_type=routing;type=w,c;code=UO1,U1 Click Connector(UO1)Body>No. 6 Floor Wire>No. 6 Floor Wire and Floor Wireewd_type=component;type=w;code=UO1;pinno=6,5,4,13,12,11 Click Connector(U1)Body>No. 6 Floor Wire>Rear Traction with Transaxle Motor Assemblyewd_type=component;type=c;code=U1;pinno=5,8,3,4,9,13 |
||
| UO1-6 (RRF) - U1-5 (RRF) | Ignition switch off | Below 1 Ω |
| UO1-5 (RRFG) - U1-8 (RRFG) | Ignition switch off | Below 1 Ω |
| UO1-4 (RSN) - U1-3 (RSN) | Ignition switch off | Below 1 Ω |
| UO1-13 (RSNG) - U1-4 (RSNG) | Ignition switch off | Below 1 Ω |
| UO1-12 (RCS) - U1-9 (RCS) | Ignition switch off | Below 1 Ω |
| UO1-11 (RCSG) - U1-13 (RCSG) | Ignition switch off | Below 1 Ω |
| Tester Connection | Switch Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(UO1,U1)Location & Routingewd_type=routing;type=w,c;code=UO1,U1 Click Connector(UO1)Body>No. 6 Floor Wire>No. 6 Floor Wire and Floor Wireewd_type=component;type=w;code=UO1;pinno=6,5,4,13,12,11 Click Connector(U1)Body>No. 6 Floor Wire>Rear Traction with Transaxle Motor Assemblyewd_type=component;type=c;code=U1;pinno=5,8,3,4,9,13 |
||
| UO1-6 (RRF) or U1-5 (RRF) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| UO1-5 (RRFG) or U1-8 (RRFG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| UO1-4 (RSN) or U1-3 (RSN) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| UO1-13 (RSNG) or U1-4 (RSNG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| UO1-12 (RCS) or U1-9 (RCS) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
| UO1-11 (RCSG) or U1-13 (RCSG) - Body ground and other terminals | Ignition switch off | 1 MΩ or higher |
The rear motor resolver is not available as a supply part. If it requires replacement, replace the rear traction motor with transaxle assembly.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
Reconnect the floor wire connector.
OK
NG