Home › Brake › PARKING BRAKE › ELECTRIC PARKING BRAKE SYSTEM (for Gasoline Model) › 2020.08–2021.07
RM3700E _54 Brake _093729 PARKING BRAKE _0444808 ELECTRIC PARKING BRAKE SYSTEM(for Gasoline Model) C

PARKING BRAKE  ELECTRIC PARKING BRAKE SYSTEM(for Gasoline Model)  C060B12  Left Electric Parking Brake Actuator Control Circuit Short to Battery  


DESCRIPTION

DTC No. Detection Item DTC Detection Condition Trouble Area Memory DTC Output from Priority Note
C060B12 Left Electric Parking Brake Actuator Control Circuit Short to Battery
·

Diagnosis Condition:

Electric parking brake not operating

·

Malfunction Status:

The ECU power supply is normal but there is a malfunction in the electric parking brake actuator LH internal circuit (short to +B).

·

Detection Time:

Approximately 1 second


·

Parking brake actuator assembly LH

·

No. 2 parking brake wire assembly

·

Wire harness or connector

·

Skid control ECU (brake actuator assembly)


DTC stored Brake/EPB A An electric parking brake system malfunction is displayed on the multi-information display.

CAUTION / NOTICE / HINT

NOTICE:
·

The electric parking brake may still operate up to 20 seconds after the ignition switch is turned off. Before disconnecting connectors or fuses, turn the ignition switch off and wait 20 seconds or more.

·

After replacing the skid control ECU (brake actuator assembly), perform "Calibration".

Click hereBrake>BRAKE CONTROL / DYNAMIC CONTROL SYSTEMS>ELECTRONICALLY CONTROLLED BRAKE SYSTEM (for Gasoline Model)>CALIBRATION

·

When replacing the skid control ECU (brake actuator assembly), operate the electric parking brake switch (electric parking brake switch assembly) as the parking brake indicator light blinks (red) when the ignition switch is first turned ON.



PROCEDURE

1.CHECK FOR SHORT TO +B

Pre-procedure1

a.

Turn the ignition switch off.


b.

Make sure the No. 2 parking brake wire assembly is securely installed.


c.

Disconnect the u3 parking brake actuator assembly LH connector.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(u3)Location & Routing

Click Connector(u3)Body>No. 1 Parking Brake Wire Assembly / No. 2 Parking Brake Wire Assembly>Parking Brake Actuator Assembly LH

u3-2 (+) - u3-1 (-) Electric parking brake not operating Below 1 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

None



OK

REPLACE PARKING BRAKE ACTUATOR ASSEMBLY LH

NG

2.CHECK FOR SHORT TO +B
2.CHECK FOR SHORT TO +B

Pre-procedure1

a.

Disconnect the uO2 No. 2 parking brake wire assembly connector.


Procedure1

a.
C390253C02
1.5,0.188 1.917,0.438 0.417,0.25 0.208,0.281 0.51,0.51 0.302,0.229 10 false *a 1.604,0.229 1.906,0.458 0.302,0.229 10 false uO2
*a Front view of wire harness connector
(to No. 2 Parking Brake Wire Assembly)


Measure the voltage according to the value(s) in the table below.

Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(uO2)Location & Routing

Click Connector(uO2)Body>No. 1 Parking Brake Wire Assembly / No. 2 Parking Brake Wire Assembly>No. 2 Parking Brake Wire Assembly and Floor Wire

uO2-1 - uO2-2 Electric parking brake not operating Below 1 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

None



OK

REPLACE NO. 2 PARKING BRAKE WIRE ASSEMBLY

NG

3.CHECK FOR SHORT TO +B
3.CHECK FOR SHORT TO +B

Pre-procedure1

a.

Disconnect the uO2 No. 2 parking brake wire assembly connector.


b.

Disconnect the A94 skid control ECU (brake actuator assembly) connector.


Procedure1

a.

Measure the voltage according to the value(s) in the table below.

C449752C01
1.781,0.417 2.198,0.667 0.417,0.25 5.552,0.375 5.969,0.625 0.417,0.25 2.135,2.26 1.51,1.375 true 0.667,2.26 1.281,1.385 true 1.854,0.479 2.313,0.677 0.458,0.198 10 false A94 5.615,0.438 6.073,0.635 0.458,0.198 10 false uO2 0.5,0.75 0.958,1.031 0.458,0.281 10 false *b 0.167,0.167 0.583,0.417 0.417,0.25 10 false *a 4.583,0.75 5.125,0.948 0.542,0.198 10 false *c 0.521,2.323 1.021,2.573 0.5,0.25 10 false MRL- 2.104,2.302 2.604,2.552 0.5,0.25 10 false MRL+
*a Front view of wire harness connector *b (to Skid Control ECU (Brake Actuator Assembly))
*c (to No. 2 Parking Brake Wire Assembly) - -


Standard Voltage:
Tester Connection Condition Specified Condition

Click Location & Routing(uO2,A94)Location & Routing

Click Connector(uO2)Body>No. 1 Parking Brake Wire Assembly / No. 2 Parking Brake Wire Assembly>No. 2 Parking Brake Wire Assembly and Floor Wire

Click Connector(A94)Engine Compartment>Engine Room Main Wire>Brake Actuator Assembly

uO2-1 or A94-3 (MRL+) - Body ground Always Below 1 V
uO2-2 or A94-2 (MRL-) - Body ground Always Below 1 V


Result:
Proceed to
OK
NG



Post-procedure1

a.

None



OK

REPLACE SKID CONTROL ECU (BRAKE ACTUATOR ASSEMBLY)

NG

REPAIR OR REPLACE HARNESS OR CONNECTOR