If the skid control ECU (brake booster with master cylinder assembly) detects that the brake fluid level is low or there is an open in the brake fluid level warning switch signal circuit, DTC C120200 is stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| C120200 | Master Reservoir Level Malfunction | ·
The brake fluid level warning switch signal circuit is open for a certain period of time. ·
The reservoir level is low for a certain period of time. |
·
Open or short in brake fluid level warning switch (brake booster with master cylinder assembly) ·
Brake fluid leaks ·
Open or short in wire harness ·
Low brake fluid ·
Skid control ECU (brake booster with master cylinder assembly) |
Brake/EPB | A |
After replacing the skid control ECU (brake booster with master cylinder assembly), perform linear solenoid valve offset learning, ABS holding solenoid valve learning, yaw rate and acceleration sensor zero point calibration and system information memorization after performing "Reset Memory".
Check the DTCs that are output.
| Result | Proceed to |
|---|---|
| Only C120200 is output | A |
| C120200 and other DTCs are output | B |
A
B
Check the vehicle specification.
| Result | Proceed to |
|---|---|
| for AWD | A |
| for 2WD | B |
A
B
Check that the brake fluid level is sufficient.
If the fluid level is low, check for fluid leaks, and repair as necessary.
Check for brake fluid leaks (connection between the brake booster pump assembly, brake master cylinder reservoir assembly (brake booster with master cylinder assembly), brake booster with master cylinder assembly, and wheel cylinders).
If no leaks exist, add and adjust fluid using the GTS.
Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE FLUID (for HV Model)>ON-VEHICLE INSPECTION
Check the thickness of the brake pad lining.
for Front Brake: Click hereBrake>BRAKE (FRONT)>FRONT BRAKE>INSPECTION
for Rear Brake: Click hereBrake>BRAKE (REAR)>REAR BRAKE (for AWD)>INSPECTION
If the thickness is less than the standard, replace the brake pads with new ones.
| Proceed to |
|---|
| NEXT |
NEXT
Check that the brake fluid level is sufficient.
If the fluid level is low, check for fluid leaks, and repair as necessary.
Check for brake fluid leaks (connection between the brake booster pump assembly, brake master cylinder reservoir assembly (brake booster with master cylinder assembly), brake booster with master cylinder assembly, and wheel cylinders).
If no leaks exist, add and adjust fluid using the GTS.
Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE FLUID (for HV Model)>ON-VEHICLE INSPECTION
Check the thickness of the brake pad lining.
for Front Brake: Click hereBrake>BRAKE (FRONT)>FRONT BRAKE>INSPECTION
for Rear Brake: Click hereBrake>BRAKE (REAR)>REAR BRAKE (for 2WD)>INSPECTION
If the thickness is less than the standard, replace the brake pads with new ones.
| Proceed to |
|---|
| NEXT |
NEXT
Check that there are no leaks from the connections between the brake booster pump assembly and brake booster with master cylinder assembly.
As a visual check is very difficult, perform the check with the following procedure.
Bleed the air from the brake system.
Click hereBrake>BRAKE SYSTEM (OTHER)>BRAKE FLUID (for HV Model)>BLEEDING
Turn the ignition switch off.
Disconnect the A27 brake pedal stroke sensor assembly connector.
Select the Data List on the GTS.
| Tester Display | Measurement Item | Range | Normal Condition | Diagnostic Note |
|---|---|---|---|---|
| MTT | Pump motor operation status | OFF / ON | OFF: Pump motor off
ON: Pump motor on |
- |
| Accumulator Pressure | Accumulator pressure output value | Min.: 0.00 MPa, Max.: 24.48 MPa | 15.00 to 21.00 MPa
(Pressure stable and pump motor stopped) |
When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator |
| Tester Display |
|---|
| MTT |
| Accumulator Pressure |
Depress the brake pedal several times to operate the pump motor, then wait until it stops.
After the pump motor stops, wait for 30 seconds, then check the drop in the accumulator pressure sensor output value and the state of the pump motor.
| Result | Proceed to |
|---|---|
| 30 seconds after the pump motor stops the drop in the value of Accumulator Pressure after the pump motor stops is less than 2.50 MPa and pump motor does not operate within 30 seconds | A |
| 30 seconds after the pump motor stops the drop in the value of Accumulator Pressure is 2.50 MPa or more or pump motor operates within 30 seconds | B |
A
B
Pre-procedure1
Turn the ignition switch off.
Reconnect the A27 brake pedal stroke sensor assembly connector.
Remove the brake master cylinder reservoir filler cap assembly.
Procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Pre-procedure2
Disconnect the A24 brake fluid level warning switch (brake booster with master cylinder assembly) connector.
Procedure2
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure3
| *a | Component without harness connected
(Brake Fluid Level Warning Switch (Brake Booster with Master Cylinder Assembly)) |
Measure the resistance according to the value(s) in the table below.
A float is located inside the brake master cylinder reservoir assembly (brake booster with master cylinder assembly). Its position changes according to the level of brake fluid.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
| 2 (E) - 1 (+) | Brake fluid level warning switch (brake booster with master cylinder assembly) off (float up) | 1.84 to 2.16 kΩ |
| 2 (E) - 1 (+) | Brake fluid level warning switch (brake booster with master cylinder assembly) on (float down) | Below 1 Ω |
If there are no problems after completing the preceding inspection, adjust the brake fluid to the MAX level with the ignition switch ON.
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Procedure1
Make sure that there is no looseness at the locking part and the connecting part of the connector.
The connector is securely connected.
Pre-procedure1
Disconnect the A38 skid control ECU (brake booster with master cylinder assembly) connector.
Procedure2
Check both the connector case and the terminals for deformation and corrosion.
No deformation or corrosion.
Procedure3
Measure the resistance according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A38,A24)Location & Routingewd_type=routing;type=c,c;code=A38,A24 Click Connector(A38)Engine Compartment>Engine Room Main Wire>Brake Booster with Master Cylinder Assemblyewd_type=component;type=c;code=A38;pinno=16 Click Connector(A24)Engine Compartment>Engine Room Main Wire>Level Warning Switch (Brake Master Cylinder Reservoir Assembly)ewd_type=component;type=c;code=A24;pinno=1,2 |
||
| A38-16 (LBL) - A24-1 (+) | Always | Below 1 Ω |
| A38-16 (LBL) or A24-1 (+) - Body ground | Always | 10 kΩ or higher |
| A24-2 (E) - Body ground | Always | Below 1 Ω |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Reconnect the A38 skid control ECU (brake booster with master cylinder assembly) connector.
Turn the ignition switch to ON.
Procedure1
Measure the voltage according to the value(s) in the table below.
| Tester Connection | Condition | Specified Condition |
|---|---|---|
|
Click Location & Routing(A24)Location & Routingewd_type=routing;type=c;code=A24 Click Connector(A24)Engine Compartment>Engine Room Main Wire>Level Warning Switch (Brake Master Cylinder Reservoir Assembly)ewd_type=component;type=c;code=A24;pinno=1 |
||
| A24-1 (+) - Body ground | Ignition switch ON | 11 to 14 V |
| Proceed to |
|---|
| OK |
| NG |
Post-procedure1
None
OK
NG
Pre-procedure1
Turn the ignition switch off.
Reconnect the A24 brake fluid level warning switch (brake booster with master cylinder assembly) connector.
Procedure1
Clear the DTCs.
| Proceed to |
|---|
| NEXT |
Post-procedure1
Turn the ignition switch off.
NEXT
Pre-procedure1
Based on the Freeze Frame Data and interview with the customer, attempt to reproduce the conditions when the malfunction occurred.
Procedure1
Check if the same DTC is output.
| Result | Proceed to |
|---|---|
| C120200 is not output | A |
| C120200 is output | B |
Post-procedure1
None
A
Click hereGeneral>INTRODUCTION>HOW TO TROUBLESHOOT ECU CONTROLLED SYSTEMS>HOW TO PROCEED WITH TROUBLESHOOTING
B