HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM(for HV Model)  Air Vent Temperature does not Change and Right Vent is Different from Left and Vice Versa (Same Left/Right Temperature Setting)  


DESCRIPTION

If the temperature of the air that blows from the left and right front registers differs, even though the same temperature is set for both sides, the following factors may be the cause.

Symptom Factor
Temperature of outlet air is cooler on left or right side

(When same temperature set for both sides)


·

Compressor with motor assembly malfunction

·

Refrigerant volume (low)

·

Mechanical locking of damper and damper link

·

Automatic light control sensor malfunction

·

Harness or connector


Temperature of outlet air is warmer on left or right side

(When same temperature set for both sides)


·

Mechanical locking of damper and damper link

·

Blockage in heater radiator unit sub-assembly

·

Harness or connector



CAUTION / NOTICE / HINT

NOTICE:

The air conditioning system uses the CAN communication system. Inspect the communication functions by following How to Proceed with Troubleshooting. Troubleshoot the air conditioning system after confirming that the communication systems are functioning properly.

Click hereVehicle Interior>HEATING / AIR CONDITIONING>AIR CONDITIONING SYSTEM (for HV Model)>HOW TO PROCEED WITH TROUBLESHOOTING


PROCEDURE

1.CHECK WHEN MALFUNCTION OCCURS
Result:
Result Proceed to
When using cooling function A
When using heater function B



A

2.CHECK FOR DTC

B

5.BLEED AIR FROM COOLING SYSTEM
2.CHECK FOR DTC
a.

Check for DTCs.

Body Electrical > Main Body > Trouble Codes
50001 449

Result:
Result Proceed to
B124400 is not output A
B124400 is output B



A

3.PERFORM REFRIGERANT SHORTAGE CHECK

B

3.PERFORM REFRIGERANT SHORTAGE CHECK
a.

Check that the following conditions are met and perform the refrigerant shortage check according to the display on the GTS.

Measurement Condition:
Item Condition
A/C switch On
Ambient temperature*1 0 to 49°C (32 to 120°F)
Blower speed HI

*1: If the ambient temperature is not within the range shown, do not perform this check.

Body Electrical > Air Conditioner > Utility
Tester Display
Refrigerant Gas Volume Check
50005 450 5578
Result:
Result Amount of Refrigerant
Refrigerant correct Correct
Refrigerant shortage Insufficient


OK:

"Refrigerant correct" is displayed on the GTS.



Result:
Proceed to
OK
NG



OK

4.PERFORM ACTIVE TEST USING GTS

NG

4.PERFORM ACTIVE TEST USING GTS
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Front Left Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Front Right Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Left Air Mix Damper Control Servo Motor
50004 450 26
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Right Air Mix Damper Control Servo Motor
50004 450 28
OK:

Each damper servo motor operates.



Result:
Proceed to
OK
NG



OK

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR

5.BLEED AIR FROM COOLING SYSTEM
a.

Bleed air from cooling system.

Click hereGeneral>MAINTENANCE>M15A-FXE COOLANT (for Engine)>REPLACEMENT


Result:
Proceed to
NEXT



NEXT

6.CHECK OPERATION (AIR CONDITIONING SYSTEM)
6.CHECK OPERATION (AIR CONDITIONING SYSTEM)
a.

Set the same temperature for the left and right sides and check that the air that blows from the left and right front registers is the same temperature.

OK:

The air from the left and right front registers is the same temperature.



Result:
Proceed to
OK
NG



OK

END (MALFUNCTION DUE TO AIR IN COOLING SYSTEM)

NG

7.PERFORM ACTIVE TEST USING GTS
7.PERFORM ACTIVE TEST USING GTS
a.

Perform the Active Test according to the display on the GTS.

Body Electrical > Air Conditioner > Active Test
Tester Display Measurement Item Control Range Diagnostic Note
Front Left Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Front Right Air Mix Damper Control Servo Motor No. 1 air conditioning radiator damper servo sub-assembly pulse Min.: 128
Max.: 384
-
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Left Air Mix Damper Control Servo Motor
50004 450 26
Body Electrical > Air Conditioner > Active Test
Tester Display
Front Right Air Mix Damper Control Servo Motor
50004 450 28
OK:

Each damper servo motor operates.



Result:
Proceed to
OK
NG



OK

NG

GO TO DTC TROUBLESHOOTING PROCEDURE FOR MALFUNCTIONING DAMPER SERVO MOTOR