Home › Vehicle Interior › HEATING / AIR CONDITIONING › BLOWER UNIT › from 2021.07
RM3700E _58 Vehicle Interior _093020 HEATING / AIR CONDITIONING _0438489 BLOWER UNIT A

HEATING / AIR CONDITIONING  BLOWER UNIT  REASSEMBLY  


CAUTION / NOTICE / HINT

COMPONENTS (REASSEMBLY)
I117531N01
0.583,1.5 2.25,4 1.667,2.5 2.323,3.667 3.604,4.667 1.281,1 4.063,3.333 4.25,3.635 4.25,3.635 4.406,3.635 false 1.125,2.938 1.333,3.083 1.333,3.083 1.5,3.083 false 2.25,2.5 0.583,2.5 false 1.375,2.104 1.688,2.104 false 6.188,3.813 6.188,3.479 false 5.719,2.76 6.052,2.76 false 2.917,4.021 3.25,4.021 false 1.99,1.958 2.271,2.313 0.281,0.354 18 false 5 1.813,2.906 2.094,3.26 0.281,0.354 18 false 6 3.333,3.865 3.615,4.219 0.281,0.354 18 false 1 4.458,3.49 4.74,3.844 0.281,0.354 18 false 4 6.354,2.573 6.635,2.927 0.281,0.354 18 false 2 6.313,3.802 6.594,4.156 0.281,0.354 18 false 3 0.635,2.542 0.917,2.896 0.281,0.354 12 false *B 0.646,1.563 0.927,1.917 0.281,0.354 12 false *A 0.854,2.063 1.167,2.24 0.313,0.177 10 false x2 3.865,3.792 4.177,3.969 0.313,0.177 10 false x3 2.646,4.427 2.958,4.604 0.313,0.177 10 false x2 2.354,3.708 2.646,3.99 0.292,0.281 12 false *B

Procedure Part Name Code
Z101186

Z101188

Z101187

1 BLOWER RESISTOR 87138C - - -
2 CLEAN AIR FILTER 87139C (Click here) - -
3 AIR FILTER COVER PLATE 88899M (Click here) - -
4 BLOWER MOTOR WITH FAN SUB-ASSEMBLY 87103B - - -
5 NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY 87130K (Click here) - -
6 AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY 55908A (Click here) - -

*A for Automatic Air Conditioning System *B for Manual Air Conditioning System

CAUTION / NOTICE / HINT

HINT:
·

Use the same procedure for LHD and RHD vehicles.

·

The following procedure is for LHD vehicles.



PROCEDURE

Hide 87138C 1.INSTALL BLOWER RESISTOR (for Manual Air Conditioning System)

Hide 87139C 2.INSTALL CLEAN AIR FILTER

Z101186

NOTICE:

Make sure that the "UP" marks is facing the correct direction before installing the clean air filter.



a.
I117532


Hide 88899M 3.INSTALL AIR FILTER COVER PLATE

Z101186

NOTICE:

Make sure that the "UP" mark is facing the correct direction before installing the air filter cover plate.



a.
I117533


Hide 87103B 4.INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY

Hide 87130K 5.INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)

a.
I117534C01
3.771,0.604 4.135,0.323 true 1.958,0.052 2.24,0.406 0.281,0.354 18 false i 4.156,0.219 4.365,0.427 0.208,0.208 10 true *a
*a Link - -


i.

Connect the link of the No. 1 blower damper servo sub-assembly to the groove on the lever of the blower assembly as shown in the illustration.


ii.

Install the No. 1 blower damper servo sub-assembly with the 2 screws.



Hide 55908A 6.INSTALL AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System)

a.
I117535C01
0.375,0.052 0.656,0.406 0.281,0.354 18 false i 2.281,0.073 2.563,0.427 0.281,0.354 10 false *a 4.75,0.854 4.969,1.063 0.219,0.208 10 true *a 2.573,1.958 2.781,2.302 0.208,0.344 18 true ii
*a Recirculation - -


i.

Set the cable gear and unit gear to the recirculation position.


ii.

Engage the claws to install the air inlet damper control cable sub-assembly.