| *1 | ROOF SIDE INNER GARNISH CLIP | - | - |
|
Tightening torque for "Major areas involving basic vehicle performance such as moving/turning/stopping": N*m (kgf*cm, ft.*lbf) | ● | Non-reusable part |
Use the same procedure for the LHD and RHD vehicles.
The procedure listed below is for the LHD vehicles.
Use the same procedure for the LH and RH sides.
The procedure listed below is for the LH side.
62170A
1.INSTALL CURTAIN SHIELD AIR BAG ASSEMBLY
| *A | w/ Entry and Start System | *B | w/o Entry and Start System |
| *a | Illumination off | - | - |
Check that the ignition switch is off.
Check that the cable is disconnected from the negative (-) auxiliary battery terminal.
Wait at least 90 seconds after disconnecting the cable from the negative (-) auxiliary battery terminal to disable the SRS system.
If the airbag deploys for any reason, it may cause a serious accident.
| *1 | Roof Side Inner Garnish Clip | - | - |
| *a | Claw (A) | *b | Claw (B) |
|
Install in this Direction | - | - |
Engage the hooks and claws (B) to temporarily install the curtain shield airbag assembly.
Do not twist the curtain shield airbag assembly when installing it.
Install the 4 new bolts.
Install the curtain shield airbag assembly with new roof side inner garnish clips.
Engage the claws(A) to install each new roof side inner garnish clip.
Push the pins into the roof side inner garnish clips.
Do not damage the pins.
Make sure that the pins of the roof side inner garnish clips are pushed in firmly.
Connect the airbag connector.
When connecting any airbag connector, take care not to damage the airbag wire harness.
Refer to How to Connect or Disconnect Airbag Connector:
63310
2.INSTALL ROOF HEADLINING ASSEMBLY
3.CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
for M15A-FKS:
Click hereGeneral>MAINTENANCE>M15A-FKS AUXILIARY BATTERY>INSTALLATION
for M15A-FXE:
Click hereGeneral>MAINTENANCE>M15A-FXE AUXILIARY BATTERY>INSTALLATION
4. PERFORM DIAGNOSTIC SYSTEM CHECK
6. INITIALIZATION AFTER RECONNECTING AUXILIARY BATTERY TERMINAL
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>WORK PROCEDURE
When disconnecting and reconnecting the auxiliary battery, there is an automatic learning function that completes learning when the respective system is used.
Click hereGeneral>SETUP>WHEN DISCONNECTING OR RECONNECTING BATTERY TERMINAL>AUTOMATIC LEARNING CHART