The linear solenoids SLA and SLR control the regulator based on signals from the skid control ECU (brake booster with master cylinder assembly) and produce servo pressure in accordance with the vehicle condition.
When the system is normal, the switching solenoid SGH is opened to allow brake fluid to flow to the stroke simulator when the brake pedal is depressed. When the system is abnormal, the switching solenoid SGH closes to prevent the flow of brake fluid.
When the system is normal, the switching solenoid SSA is closed. When the system is abnormal, the switching solenoid SSA is opened to allow fluid to flow to the brake master cylinder reservoir assembly.
If the supply voltage decreases, a drop in current may cause DTCs to be stored.
| DTC No. | Detection Item | DTC Detection Condition | Trouble Area | DTC Output from | Priority |
|---|---|---|---|---|---|
| C13C015 | Brake Pressure Control Solenoid "A" Control Circuit Short to Battery or Open | An open is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C018 | Brake Pressure Control Solenoid "A" Control Circuit Current Below Threshold | Insufficient current is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C019 | Brake Pressure Control Solenoid "A" Control Circuit Current Above Threshold | Any of the following is detected:
·
Overcurrent is detected in the solenoid for 0.05 seconds or more. ·
An excessive current is detected in the solenoid for 0.05 seconds or more. |
·
Supply voltage reduced ·
Brake booster with master cylinder assembly |
Brake/EPB | A |
| C13C01C | Brake Pressure Control Solenoid "A" Control Circuit Voltage Out of Range | A malfunction in the solenoid current monitoring circuit is detected for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C028 | Brake Pressure Control Solenoid "A" Control Signal Bias Level Out of Range / Zero Adjustment Failure | Current leakage is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C915 | Brake Pressure Control Solenoid "B" Control Circuit Short to Battery or Open | An open is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C918 | Brake Pressure Control Solenoid "B" Control Circuit Current Below Threshold | Insufficient current is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C919 | Brake Pressure Control Solenoid "B" Control Circuit Current Above Threshold | ·
Overcurrent is detected in the solenoid for 0.05 seconds or more. ·
An excessive current is detected in the solenoid for 0.05 seconds or more. |
Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C91C | Brake Pressure Control Solenoid "B" Control Circuit Voltage Out of Range | A malfunction in the solenoid current monitoring circuit is detected for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C13C928 | Brake Pressure Control Solenoid "B" Control Signal Bias Level Out of Range / Zero Adjustment Failure | Current leakage is detected in the solenoid for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14F115 | Brake Pressure Control Solenoid "C" Control Circuit Short to Battery or Open | An open is detected in SSA for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14F118 | Brake Pressure Control Solenoid "C" Control Circuit Current Below Threshold | Monitoring value of SSA continues to be excessively lower than request value. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14F119 | Brake Pressure Control Solenoid "C" Control Circuit Current Above Threshold | ·
Overcurrent is detected in SSA for 0.05 seconds or more. ·
Monitoring value of SSA continues to be excessively higher than request value. |
·
Supply voltage reduced ·
Brake booster with master cylinder assembly |
Brake/EPB | A |
| C14F11C | Brake Pressure Control Solenoid "C" Control Circuit Voltage Out of Range | A malfunction in the SSA current monitoring circuit is detected for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14F128 | Brake Pressure Control Solenoid "C" Control Signal Bias Level Out of Range / Zero Adjustment Failure | Current leakage is detected in SSA for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14FA15 | Brake Pressure Control Solenoid "D" Control Circuit Short to Battery or Open | An open is detected in SGH for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14FA18 | Brake Pressure Control Solenoid "D" Control Circuit Current Below Threshold | Monitoring value of SGH continues to be excessively lower than request value. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14FA19 | Brake Pressure Control Solenoid "D" Control Circuit Current Above Threshold | ·
Overcurrent is detected in SGH for 0.05 seconds or more. ·
Monitoring value of SGH continues to be excessively higher than request value. |
·
Supply voltage reduced ·
Brake booster with master cylinder assembly |
Brake/EPB | A |
| C14FA1C | Brake Pressure Control Solenoid "D" Control Circuit Voltage Out of Range | A malfunction in the SGH current monitoring circuit is detected for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
| C14FA28 | Brake Pressure Control Solenoid "D" Control Signal Bias Level Out of Range / Zero Adjustment Failure | Current leakage is detected in SGH for 0.05 seconds or more. | Brake booster with master cylinder assembly | Brake/EPB | A |
After replacing the brake booster with master cylinder assembly, perform linear solenoid valve offset learning, ABS holding solenoid valve learning, yaw rate and acceleration sensor zero point calibration and system information memorization after performing "Reset Memory".
| Proceed to |
|---|
| NEXT |
NEXT