Home › Power Source / Network › M15A-FKS (BATTERY / CHARGING) › GENERATOR (for 120A Type) › from 2021.07
RM3700E _57 Power Source / Network _092979 M15A-FKS BATTERY / CHARGING _0485216 GENERATOR(for 120A Type) A

M15A-FKS BATTERY / CHARGING  GENERATOR(for 120A Type)  REASSEMBLY  


CAUTION / NOTICE / HINT

COMPONENTS (REASSEMBLY)
A495861N01
5.771,4.969 6.771,5.135 1,0.167 5.51,2.427 6.51,2.594 1,0.167 3.156,2.927 4.156,3.094 1,0.167 0.823,2.51 1.656,2.844 0.833,0.333 2,2.563 3.083,2.729 1.083,0.167 3.885,2.688 4.885,2.854 1,0.167 3.76,1.625 3.76,1.406 false 5.406,1.521 5.406,1.24 false 6.333,0.906 6.333,0.625 false 2.76,4.948 2.76,4.667 false 1.813,5.635 1.813,5.438 false 4.406,5.479 4.573,5.646 4.573,5.646 4.74,5.646 false 0.667,5.635 3.583,5.635 3.583,5.635 3.583,4.969 false 6.406,4.563 6.406,4.281 false 5.083,4.656 5.083,4.375 false 1.458,0.521 1.625,0.521 1.625,0.521 1.833,1.417 false 4.333,1.802 4.333,1.333 false 5.25,3.417 5.594,5.052 5.594,5.052 5.76,5.052 false 6.792,2.854 6.677,2.5 6.677,2.5 6.51,2.5 false 0.76,1.073 0.594,1.073 0.594,1.073 0.521,1.688 false 0.594,2.604 0.594,2.438 0.594,2.438 1.031,2.135 false 2,2.646 1.833,2.646 1.833,2.646 1.719,2.354 false 2.958,0.396 2.792,0.396 2.792,0.396 2.75,0.656 false 4.156,3.01 4.323,3.01 4.323,3.01 4.458,3.177 false 4.896,2.771 5.063,2.771 5.063,2.771 5.24,3.146 false 0.802,0.958 0.958,1.156 0.156,0.198 10 false ● 0.927,0.885 1.177,1.281 0.25,0.396 18 false 9 3,0.292 3.229,0.49 0.229,0.198 10 false *1 5.344,1.521 5.594,1.917 0.25,0.396 18 false 2 4.708,3.021 5.052,3.24 0.344,0.219 10 false x4 5.396,3.021 5.74,3.24 0.344,0.219 10 false x2 5.385,3.271 5.729,3.49 0.344,0.219 10 false x2 1.781,2.26 2.01,2.458 0.229,0.198 10 false x4 2.781,4.99 3.031,5.385 0.25,0.396 18 false 3 4.781,5.448 5.052,5.771 0.271,0.323 18 false 6 0.375,5.448 0.646,5.74 0.271,0.292 18 false 4 6.333,4.552 6.604,4.875 0.271,0.323 18 false 7 5.01,4.656 5.281,4.979 0.271,0.323 18 false 5 0.531,2.604 0.688,2.802 0.156,0.198 10 false ● 0.635,2.542 0.885,2.938 0.25,0.396 18 false 8 4.438,1.802 4.688,2.198 0.25,0.396 18 false 1 5.823,4.958 6.802,5.125 0.979,0.167 8 false 1.8 (18, 16 in.*lbf) 5.563,2.427 6.542,2.594 0.979,0.167 8 false 4.6 (47, 41 in.*lbf) 0.854,2.521 1.573,2.698 0.719,0.177 8 false 80 (816, 59) 0.854,2.667 1.719,2.865 0.865,0.198 8 false 74.4 (759, 55)* 2.073,2.573 3.052,2.74 0.979,0.167 8 false 2.3 (23, 20 in.*lbf) 1.188,0.365 1.438,0.76 0.25,0.396 18 false 8 3.75,1.635 3.906,1.833 0.156,0.198 10 false ● 3.833,1.594 4.083,1.99 0.25,0.396 18 false 1 6.323,0.906 6.573,1.302 0.25,0.396 18 false 2 6.219,0.948 6.375,1.146 0.156,0.198 10 false ● 3.198,2.927 4.177,3.094 0.979,0.167 8 false 5.6 (57, 50 in.*lbf) 6.896,2.771 7.125,2.958 0.229,0.188 10 false x3 3.927,2.688 4.906,2.854 0.979,0.167 8 false 1.8 (18, 16 in.*lbf)

Procedure Part Name Code
Z101186

Z101188

Z101187

1 RETAINER PLATE 27312 (Click here) - -
2 GENERATOR ROTOR ASSEMBLY 27330 - - -
3 GENERATOR BEARING COVER PACKING 27444 (Click here) - -
4 GENERATOR COIL ASSEMBLY 27360 (Click here) - -
5 GENERATOR REGULATOR ASSEMBLY 27700A - - -
6 GENERATOR TERMINAL INSULATOR 27387B - - -
7 GENERATOR REAR END COVER 27039 - - -
8 GENERATOR PULLEY WITH CLUTCH 27415 (Click here) - -
9 GENERATOR PULLEY CAP 27416 - - -

*1 GENERATOR DRIVE END FRAME - -
V100146

N*m (kgf*cm, ft.*lbf): Specified torque * For use with SST
● Non-reusable part - -

PROCEDURE

Hide 27312 1.INSTALL RETAINER PLATE

a.
A495871N01
1.24,0.885 0.448,0.771 0.448,0.771 1.344,0.625 true 2.771,0.729 3.146,0.323 3.146,0.323 2.594,0.469 true 0.354,0.052 0.635,0.406 0.281,0.354 18 false i 3.917,0.052 4.198,0.406 0.281,0.354 18 false ii 0.115,0.667 0.5,0.885 0.385,0.219 10 false SST 3.188,0.219 3.573,0.438 0.385,0.219 10 false SST

i.

Using SST and a press, install a new generator drive end frame bearing.

SST
09950-60010  (09951-00470)
09950-70010  (09951-07100)


ii.

Install the retainer plate to the generator drive end frame with the 4 bolts.

Torque:
2.3 N*m (23 kgf*cm, 20 in.*lbf)



Hide 27330 2.INSTALL GENERATOR ROTOR ASSEMBLY

Hide 27444 3.INSTALL GENERATOR BEARING COVER PACKING

Z101186

NOTICE:

Align the protrusions of the bearing cover packing with the grooves of the generator coil assembly when installing.



a.
A495872C01
3.677,0.271 3.927,0.271 true 3.677,0.854 3.927,0.854 true 3.948,0.167 4.229,0.521 0.281,0.354 10 false *a 3.948,0.74 4.229,1.094 0.281,0.354 10 false *b
*a Protrusion *b Groove



Hide 27360 4.INSTALL GENERATOR COIL ASSEMBLY

a.
A495873C01
4.323,0.469 4.927,0.271 true 2.708,0.302 3.146,0.521 true 1.813,0.052 2.302,0.375 0.49,0.323 18 false i, ii 4.948,0.156 5.26,0.354 0.313,0.198 10 false *a 2.531,0.167 2.844,0.365 0.313,0.198 10 false *a
*a 21 mm Deep Socket Wrench - -


i.

Using a 21 mm deep socket wrench and press, slowly press in the generator coil assembly.


ii.

Install the 4 bolts.

Torque:
5.6 N*m (57 kgf*cm, 50 in.*lbf)



Hide 27700A 5.INSTALL GENERATOR REGULATOR ASSEMBLY

Torque:
1.8 N*m (18 kgf*cm, 16 in.*lbf)

Hide 27387B 6.INSTALL GENERATOR TERMINAL INSULATOR

Hide 27039 7.INSTALL GENERATOR REAR END COVER

Torque:
4.6 N*m (47 kgf*cm, 41 in.*lbf)

Hide 27415 8.INSTALL GENERATOR PULLEY WITH CLUTCH

a.
A495875C01
1.01,1.156 1.365,1.365 true 2.083,1.635 2.24,2.063 true 1.552,2.5 1.885,2.5 false 3.521,1.063 3.906,1.219 true 4.448,1.615 4.646,2.083 true 4.031,2.51 4.365,2.51 false 6.135,1.406 6.469,1.406 true 6.313,2.365 6.74,1.563 true 6.417,2.396 6.719,1.823 true 5.063,3.083 5.177,2.844 true 0.448,0.427 0.865,0.74 0.417,0.313 18 false i, ii 0.813,1.052 1.229,1.365 0.417,0.313 10 false *1 2.063,2.073 2.531,2.313 0.469,0.24 10 false SST A 1.927,2.396 2.396,2.635 0.469,0.24 10 false SST A 3.021,0.427 3.438,0.74 0.417,0.313 18 false iii 3.323,0.958 3.74,1.271 0.417,0.313 10 false *2 4.479,2.115 4.948,2.354 0.469,0.24 10 false SST B 4.396,2.417 4.865,2.656 0.469,0.24 10 false SST B 5.521,0.427 6.094,0.792 0.573,0.365 18 false iv, v 6.719,1.396 7.156,1.583 0.438,0.188 10 false SST B 6.729,1.708 7.156,1.885 0.427,0.177 10 false SST A 4.938,3.073 5.167,3.281 0.229,0.208 10 false *b 6.083,2.688 6.292,2.875 0.208,0.188 10 true *a 5.927,1.292 6.156,1.5 0.229,0.208 10 false *c
*1 Rotor Shaft *2 Generator Pulley with Clutch
*a Torque Wrench Fulcrum Length *b Turn
*c Hold - -


i.

Temporarily install a new generator pulley with clutch to the rotor shaft.


ii.

Fit the rotor shaft end into SST (A).

SST
09820-70010  (09821-70010, 09822-70010)


iii.

Fit SST (B) to the generator pulley with clutch.


iv.

Using a 17 mm union nut wrench, tighten the generator pulley with clutch by turning SST (B) as shown in the illustration.

Torque:
Specified tightening torque : 80 N*m (816 kgf*cm, 59 ft.*lbf)

HINT:
·

Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.

Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION

·

When using a 17 mm union nut wrench (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 400 mm (1.312 ft.)): 74.4 N*m (759 kgf*cm, 55 ft.*lbf)




v.

Remove SST (A) and (B) from the generator pulley with clutch.



Hide 27416 9.INSTALL GENERATOR PULLEY CAP