| *1 | GENERATOR DRIVE END FRAME | - | - |
|
N*m (kgf*cm, ft.*lbf): Specified torque | * | For use with SST |
| ● | Non-reusable part | - | - |
27312
1.INSTALL RETAINER PLATE
Using SST and a press, install a new generator drive end frame bearing.
Install the retainer plate to the generator drive end frame with the 4 bolts.
27330
2.INSTALL GENERATOR ROTOR ASSEMBLY
27444
3.INSTALL GENERATOR BEARING COVER PACKING
|
|
| *a | Protrusion | *b | Groove |
27360
4.INSTALL GENERATOR COIL ASSEMBLY
| *a | 21 mm Deep Socket Wrench | - | - |
Using a 21 mm deep socket wrench and press, slowly press in the generator coil assembly.
Install the 4 bolts.
27700A
5.INSTALL GENERATOR REGULATOR ASSEMBLY
27387B
6.INSTALL GENERATOR TERMINAL INSULATOR
27039
7.INSTALL GENERATOR REAR END COVER
27415
8.INSTALL GENERATOR PULLEY WITH CLUTCH
| *1 | Rotor Shaft | *2 | Generator Pulley with Clutch |
| *a | Torque Wrench Fulcrum Length | *b | Turn |
| *c | Hold | - | - |
Temporarily install a new generator pulley with clutch to the rotor shaft.
Fit the rotor shaft end into SST (A).
Fit SST (B) to the generator pulley with clutch.
Using a 17 mm union nut wrench, tighten the generator pulley with clutch by turning SST (B) as shown in the illustration.
Calculate the torque wrench reading when changing the fulcrum length of the torque wrench.
Click hereGeneral>INTRODUCTION>REPAIR INSTRUCTION>PRECAUTION
When using a 17 mm union nut wrench (fulcrum length of 30 mm (1.18 in.)) + torque wrench (fulcrum length of 400 mm (1.312 ft.)): 74.4 N*m (759 kgf*cm, 55 ft.*lbf)
Remove SST (A) and (B) from the generator pulley with clutch.
27416
9.INSTALL GENERATOR PULLEY CAP