Home › Vehicle Interior › HEATING / AIR CONDITIONING › AIR CONDITIONING SYSTEM › from 2017.01
NM19S0E _58 Vehicle Interior _051436 HEATING / AIR CONDITIONING _0247906 AIR CONDITIONING SYSTEM UN GENERAL/CONTROL/DETAILS F

HEATING / AIR CONDITIONING  AIR CONDITIONING SYSTEM  GENERAL/CONTROL/DETAILS  DETAILS  


FUNCTION OF MAIN COMPONENTS


a.

The air conditioning system consists of the following parts:

Component Function
Air Conditioning Control Assembly*1 Allows operation and adjustment of the air conditioning system via switches.
No. 1 Heater Control Sub-assembly*2 Allowing the A/C switch to be turned on or off manually and the air outlet temperature to be adjusted manually.
No. 2 Heater Control Sub-assembly*2 Allows the blower control and the fresh-air/recirculation mode to be selected manually.
No. 3 Heater Control Sub-assembly*2 Allows the A/C switch to be turned on or off manually and the air outlet temperature to be adjusted manually.
Air Conditioning Amplifier Assembly Transmits and receives data between the switches and sensors.
Compressor with Pulley Assembly A continuously variable capacity type cooler compressor is used to steplessly control the refrigerant discharge capacity, thus improving comfort and achieving energy savings.
Blower with Fan Motor Assembly High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.
Cooler Condenser Assembly A Global Inner-fin Condenser (GIC) is used to improve the efficiency of cooling performance.
Heater Radiator Unit Sub-assembly A Straight Flow Aluminum (SFA)-II heater radiator is used for compactness and high performance.
No. 1 Cooler Evaporator Sub-assembly A Revolutionary super-Slim structure (RS) evaporator is used for compactness.
No. 1 Cooler Thermistor Detects the temperature of the cool air past the No. 1 cooler evaporator sub-assembly and transmits the data to the air conditioning amplifier assembly.
Thermistor Assembly Detects ambient temperature and outputs it to the air conditioning amplifier assembly.
Cooler (Room Temperature Sensor) Thermistor*1 Detects room temperature and outputs it to the air conditioning amplifier assembly.
Automatic Light Control Sensor*1 Detects the changes in the amount of solar energy and outputs them to the air conditioning amplifier assembly.
Air Mix Servo Motor (No. 1 Air Conditioning Radiator Damper Servo Sub-assembly)*1 Receives the input of temperature setting dial signals via the air conditioning amplifier assembly, operates the motor, and opens and closes the air mix damper.
Air Inlet Servo Motor (No. 1 Blower Damper Servo Sub-assembly)*1 Receives the input of the operation signals from the fresh-air/recirculation selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the fresh-air/recirculation damper.
Air Outlet Servo Motor (No. 2 Air Conditioning Radiator Damper Servo Sub-assembly)*1 Receives the input of the operation signals from the mode selector switch via the air conditioning amplifier assembly, operates the motor, and opens and closes the mode damper.
Clean Air Filter Removes particles to provide a comfortable interior space.
Air Conditioning Pressure Sensor Detects the refrigerant pressure and sends the data to the air conditioning amplifier assembly.
E.F.I. Engine Coolant Temperature Sensor Detects the engine coolant temperature and transmits it to the ECM.
ECM Receives the signals from the E.F.I. engine coolant temperature sensor and transmits them to the air conditioning amplifier assembly.

*1: Models with Automatic Air Conditioning System

*2: Models with Manual Air Conditioning System




SYSTEM CONTROL


a.

Control List

i.

The air conditioning system uses the following types of control.

Control Outline Air Conditioning Type
Automatic Manual
Neural Network Control This control is capable of effecting complex control by artificially simulating the information processing method of the nervous system of living organisms in order to establish a complex input or output relationship that is similar to a human brain. ○ -
Outlet Air Temperature Control In compliance with the temperature set at the temperature control switch, the neural network control calculates the outlet temperature based on the input signals from various sensors. In addition, corrections in accordance with the signals from the No. 1 cooler thermistor and the E.F.I. engine coolant temperature sensor are added to control the outlet air temperature. ○ -
Blower Control Controls the blower with fan motor sub-assembly in accordance with the airflow volume that has been calculated by the neural network control based on the input signals from various sensors. ○ -
Air Outlet Control Automatically switches the outlets in accordance with the outlet mode ratio that has been calculated by the neural network control based on the input signals from various sensors. ○ -
Air Inlet Control Automatically controls the air inlet control damper in accordance with the airflow volume that has been calculated by the neural network control. ○ -
Refrigerant Volume Detection Control Judges a shortage of refrigerant volume based on signals from each sensor and informs the user by turning off the indicator light of the A/C switch. ○ ○
Variable Capacity Compressor Control Controls the compressor with pulley assembly to turn on or off and the discharge capacity based on the signals from various sensors. ○ ○
Self-diagnosis The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the memory in the form of a Diagnostic Trouble Code (DTC). ○ ○

○: Equipped

-: Not equipped




b.

Neural Network Control

i.

Previously, in automatic air conditioning systems without neural network control, the air conditioning amplifier assembly determined the required outlet air temperature and blower air volume in accordance with the calculation formula that has been obtained based on information received from the sensors. However, because the senses of a person are rather complex, a given temperature is sensed differently, depending on the environment in which the person is situated. For example, a given amount of solar radiation can feel comfortably warm in a cold climate, or extremely uncomfortable in a hot climate. Therefore, as a technique for effecting a higher level of control, a neural network has been adopted in the automatic air conditioning system. With this technique, the data that has been collected under varying environmental conditions is stored in the air conditioning amplifier assembly. The air conditioning amplifier assembly can then effect control to provide enhanced air conditioning comfort.


ii.

The neural network control consists of neurons in the input layer, intermediate layer and output layer. The input layer neurons process the input data of the ambient temperature, the amount of sunlight, and the room temperature based on the outputs of the switches and sensors, and output them to the intermediate layer neurons. Based on this data, the intermediate layer neurons adjust the strength of the links among the neurons. The sum of these is then calculated by the output layer neurons in the form of the required outlet temperature, solar correction, target airflow volume, and outlet mode control volume. Accordingly, the air conditioning amplifier assembly controls the servo motors and blower motor in accordance with the control volumes that have been calculated by the neural network control.

Y111168E08
2.844,0.094 4.073,0.406 1.229,0.313 10 false Intermediate Layer 4.271,0.76 5.979,1.25 1.708,0.49 10 false Target Output Temperature 2.229,3.885 3.125,4.521 0.896,0.635 10 false Target Outlet Temperature 1.406,1.292 2.677,1.604 1.271,0.313 10 false Amount of Sunlight 2.26,6.635 3.125,6.948 0.865,0.313 10 false Outlet Mode 0.313,6.938 1.177,7.25 0.865,0.313 10 false Sensor Input 0.365,8.073 1.229,8.385 0.865,0.313 10 false Switch Input 0.573,9.542 2.75,9.854 2.177,0.313 10 false : Neural network operation range 2.313,7.875 3.177,8.188 0.865,0.313 10 false Inlet Mode 2.26,8.844 3.125,9.156 0.865,0.313 10 false Compressor 2.073,4.604 3.344,5.229 1.271,0.625 10 false Amount of Sunlight Correction 0.333,5.104 1.26,5.729 0.927,0.625 10 false Temperature Setting 3.698,4.198 4.51,5.031 0.813,0.833 10 false Temperature Control Correction 3.646,7.729 4.573,8.354 0.927,0.625 10 false Various Types of Corrections 3.573,6.49 4.594,7.115 1.021,0.625 10 false Various Types of Corrections 3.573,5.271 4.604,6.156 1.031,0.885 10 false Various Types of Airflow Volume Corrections 2.458,2.802 3.031,3.094 0.573,0.292 10 false Control 0.25,3.625 1.365,3.938 1.115,0.313 10 false Input Processing 2.094,3.229 3.313,3.542 1.219,0.313 10 false Neural Networking 5.26,3.427 6.792,3.76 1.531,0.333 10 false Output Processing 1.26,0.74 2.615,1.167 1.354,0.427 10 false Ambient Temperature 2.208,5.406 3.271,6.031 1.063,0.625 10 false Target Airflow Volume 1.979,0.396 2.75,0.708 0.771,0.313 10 false Input Layer 3.958,0.396 4.854,0.708 0.896,0.313 10 false Output Layer 5.063,5.396 6.792,6.063 1.729,0.667 10 false Blower with Fan Motor Sub-assembly 5,3.938 6.854,5.104 1.854,1.167 10 false Air Mix Servo Motor (No. 1 Air Conditioning Radiator Damper Servo Sub-assembly) 5.021,6.219 6.875,7.417 1.854,1.198 10 false Air Outlet Servo Motor (No. 2 Air Conditioning Radiator Damper Servo Sub-assembly) 5.021,7.594 6.865,8.583 1.844,0.99 10 false Air Inlet Servo Motor (No. 1 Blower Damper Servo Sub-assembly) 4.99,8.688 6.917,9.385 1.927,0.698 10 false Compressor with Pulley Assembly



c.

Refrigerant Volume Detection Control

i.

The air conditioning amplifier assembly judges the volume of refrigerant from the ambient temperature, refrigerant pressure and the temperature of the cool air past the No. 1 cooler evaporator sub-assembly. When the air conditioning amplifier assembly judges refrigerant shortage, it turns off the indicator light of the A/C switch. At that time, the compressor with pulley assembly stops operating.

Y210652E01
0.208,0.385 1.792,0.781 1.583,0.396 10 false Air Conditioning Pressure Sensor 0.219,1.063 2.031,1.271 1.813,0.208 10 false - Refrigerant Pressure Signal 0.219,2.156 1.688,2.344 1.469,0.188 10 false No.1 Cooler Thermistor 0.219,2.49 1.792,2.708 1.573,0.219 10 false - Air Temperature Signal 0.208,3.604 1.677,3.792 1.469,0.188 10 false Thermistor Assembly 0.208,3.927 2.188,4.146 1.979,0.219 10 false - Ambient Temperature Signal 0.208,5.104 2.052,5.323 1.844,0.219 10 false Combination Meter Assembly 0.542,6.125 2.385,6.344 1.844,0.219 10 false : CAN Communication Line 0.552,6.458 2.396,6.677 1.844,0.219 10 false : LIN Communication Line 2.906,2.417 4.135,2.802 1.229,0.385 10 false Air Conditioning Amplifier Assembly 4.729,0.385 6.01,0.792 1.281,0.406 10 false No. 1 Heater Control Sub-assembly*1 4.875,1.104 6.115,1.292 1.24,0.188 10 false A/C Switch 5.042,1.542 6.281,1.729 1.24,0.188 10 false Indicator Light 4.74,2.479 6.219,2.875 1.479,0.396 10 false Air Conditioning Control Assembly*2 4.875,3.198 6.115,3.385 1.24,0.188 10 false A/C Switch 5.031,3.635 6.271,3.823 1.24,0.188 10 false Indicator Light 4.74,4.583 6.865,4.844 2.125,0.26 10 false Compressor with Pulley Assembly 4.885,5.323 6.333,5.583 1.448,0.26 10 false Solenoid Control Valve 3.719,5.99 6.76,6.198 3.042,0.208 10 false *1: Models with Manual Air Conditioning System 3.719,6.323 6.938,6.542 3.219,0.219 10 false *2: Models with Automatic Air Conditioning System




CONSTRUCTION


a.

Heater Control Sub-assemblies (Models with Manual Air Conditioning System)

i.

A rotary switch type heater control sub-assemblies is used.


ii.

5 air outlet modes are provided on the control panel. To enable finer mode settings, a positive feel is provided between the positions of these modes, thus achieving a high comfort level.

Y181925E01
1.894,1.214 2.097,1.390 0.203,0.175 10 *1 2.081,1.277 2.18,1.277 2.18,1.277 2.606,0.9 false 2.629,1.463 2.832,1.639 0.203,0.175 10 *2 2.816,1.526 2.916,1.526 2.916,1.526 3.401,1.047 false 5.002,1.427 5.205,1.603 0.203,0.175 10 *3 4.989,1.491 4.89,1.491 4.89,1.491 4.405,1.012 false

Text in Illustration
*1 No. 1 Heater Control Sub-assembly *2 No. 2 Heater Control Sub-assembly
*3 No. 3 Heater Control Sub-assembly - -


iii.

A control cable is used. This cable is circular, and is placed around the cable pulleys that are provided at the heater control sub-assembly and the damper.


iv.

The operation effort of the heater control sub-assembly is transmitted to the damper via the control cable, which always moves in the pulling direction. Due to the consistent action point of the pulleys, the fluctuation of the operating effort has been minimized through the use of the pulleys. These measures have ensured ease of use and have reduced the operating effort.

Y108971E08
0.927,1.375 1.542,1.375 true 5.281,0.979 6,0.979 true 4.719,0.406 5.969,0.406 true 0.969,1.958 1.99,1.958 true 4.531,2.042 6.063,2.042 true 0.51,1.271 0.969,1.49 0.458,0.219 10 false *1 (*a) 6.042,0.896 6.5,1.115 0.458,0.219 10 false *1 (*b) 0.792,1.865 1.25,2.083 0.458,0.219 10 false *2 5.99,0.333 6.448,0.552 0.458,0.219 10 false *2 6.115,1.958 6.573,2.177 0.458,0.219 10 false *3

Text in Illustration
*1 Pulley *2 Base of Pulley
*3 Control Cable - -
*a Heater Control Sub-assembly Side *b Damper Side



b.

Air Conditioning Control Assembly (Models with Automatic Air Conditioning System)

i.

A push button type air conditioning control assembly is used.


ii.

An air conditioning control assembly with Liquid Crystal Display (LCD) is used to ensure excellent visibility.

Y181926E01
2.281,0.112 2.572,0.315 0.291,0.202 10 *a 2.476,0.202 2.576,0.202 2.576,0.202 3.256,0.722 false

Text in Illustration
*a LCD - -



c.

Air Conditioning Unit Assembly

i.

The air conditioning unit consists of the heater radiator unit sub-assembly, No. 1 cooler evaporator sub-assembly, No. 1 cooler thermistor and damper servo sub-assemblies.


ii.

A semi-center location air conditioning unit, in which the heater radiator unit sub-assembly and No. 1 cooler evaporator sub-assembly are placed in the vehicle's longitudinal direction, is used.

Y183263E02
1.198,0.635 1.302,0.635 1.302,0.635 3.021,1.865 true 4.771,3.302 4.677,3.302 4.677,3.302 4.219,2.406 true 1.01,0.563 1.24,0.74 0.229,0.177 10 false *1 4.813,3.229 5.042,3.406 0.229,0.177 10 false *2

Text in Illustration
*1 No. 1 Cooler Evaporator Sub-assembly *2 Heater Radiator Unit Sub-assembly


iii.

A partial recirculation system is used. This system has an air inlet control door (sub) in the air inlet duct. Thus, it is able to cycle a small volume of recirculated air even in the FRESH mode, thus enhancing heating performance. When the blower switch is on, the suction force of the blower fan opens this air inlet control door (sub).

Y183264E01
2.872,0.469 3.072,0.645 0.200,0.177 10 *a 4.417,1.418 4.617,1.595 0.200,0.177 10 *a 4.053,0.378 4.265,0.548 0.212,0.171 10 *b 3.389,2.428 3.606,2.599 0.218,0.171 10 *c 2.269,0.74 2.457,0.928 0.188,0.188 10 *1 2.442,0.812 2.541,0.812 2.541,0.812 4.025,1.479 false 4.549,0.885 4.737,1.073 0.188,0.188 10 *2 4.525,0.971 4.426,0.971 4.426,0.971 3.387,0.731 false 2.234,2.243 2.423,2.431 0.188,0.188 10 *3 2.407,2.315 2.506,2.315 2.506,2.315 2.886,1.993 false

Text in Illustration
*1 Air Inlet Control Door (Sub) *2 Air Inlet Control Door
*3 Air Inlet Duct - -
*a RECIRC *b FRESH
*c To Blower Fan - -
V100135

Air Flow - -



d.

No. 1 Cooler Evaporator Sub-assembly

i.

A Revolutionary super-Slim structure (RS) evaporator is used. By placing the tanks at the top and the bottom of the No. 1 cooler evaporator sub-assembly and by using a micropore tube construction, the following effects have been achieved:

·

Heat exchanging efficiency is ensured.

·

Temperature distribution is made uniform.

·

The No. 1 cooler evaporator sub-assembly is made thinner.


Y108975E05
1.885,0.385 2.115,0.385 2.115,0.385 2.354,0.938 true 5.5,0.396 5.271,0.396 5.271,0.396 5.031,0.948 true 3.427,3.417 3.198,3.417 3.198,3.417 2.969,2.865 true 6.01,2.698 5.781,2.698 5.781,2.698 5.552,2.146 true 1.708,0.313 2.031,0.563 0.323,0.25 10 false *1 3.479,3.344 3.802,3.594 0.323,0.25 10 false *1 5.542,0.333 5.865,0.583 0.323,0.25 10 false *2 6.073,2.521 6.396,2.771 0.323,0.25 10 false *3

Text in Illustration
*1 Tank *2 Micropore Tube
*3 Cooling Fin - -



e.

No. 1 Cooler Thermistor

i.

The No. 1 cooler thermistor detects the temperature of the cool air immediately past the No. 1 cooler evaporator sub-assembly in the form of resistance changes, and outputs it to the air conditioning amplifier assembly.



f.

Heater Radiator Unit Sub-assembly

i.

The heater radiator unit sub-assembly has been made more compact and performance has been improved by making the core section finer and improving the shapes of the tank section and flow section. Also, the environment has been considered. By using aluminum as the material, the amount of the environmental burden disposal (lead) has been reduced.

Y108976



g.

Blower with Fan Motor Sub-assembly

i.

High magnetic force magnets and ball bearings are used to achieve a compact and lightweight assembly.



h.

Bus Connector (Air Conditioning Harness Assembly)

i.

The bus connector (air conditioning harness assembly) has a built-in communication/driver IC, which communicates with each servo motor connector, actuates the servo motor, and has a position detection function. This enables bus communication for the servo motor wire harness to achieve a more lightweight construction and a reduced number of wires.

Y111170E08
4.573,1.594 4.573,0.781 4.573,0.781 4.74,0.781 true 4.677,1.708 4.677,1.198 4.677,1.198 4.844,1.198 true 0.135,0.156 3.823,0.635 3.688,0.479 12 false Models with Automatic Air Conditioning System: 0.5,1 2.917,1.406 2.417,0.406 10 false Air Conditioning Amplifier Assembly 1.094,1.74 2.573,2.063 1.479,0.323 10 false Communication Circuit 1.74,2.208 2.146,2.5 0.406,0.292 10 false CPU 4.813,0.708 6.198,1.031 1.385,0.323 10 false Bus Connector 4.917,1.115 6.563,1.458 1.646,0.344 10 false Communication/Driver IC 5.771,3.167 6.885,3.458 1.115,0.292 10 false Servo Motor 4.479,2.219 5.594,2.51 1.115,0.292 10 false Servo Motor



i.

Servo Motor

i.

In contrast to the previous type that detects the position by way of a potentiometer voltage, the pulse pattern type servo motor detects the relative position by way of the 2-bit on/off signals.


ii.

The forward and reverse revolutions of this motor are detected by way of 2 phases, A and B, which output 4 types of patterns. The air conditioning amplifier assembly counts the number of pulse patterns in order to determine the stopped position.

Y111171E05
4,2.583 3.729,2.583 3.729,2.583 3.5,2.927 false 3.479,2.24 3.167,2.24 3.167,2.24 2.875,3.021 false 3.938,3.021 4.396,3.021 false 4.104,3.292 4.271,3.49 4.271,3.49 4.417,3.49 false 3.271,4.635 3.417,4.49 3.417,4.49 3.542,4.49 false 2.229,0.75 2.063,0.75 2.063,0.75 1.802,1.333 false 0.167,1.052 0.781,1.385 0.615,0.333 10 Phase B 0.167,1.365 0.781,1.698 0.615,0.333 10 Phase A 0.146,1.688 0.76,2.021 0.615,0.333 10 Common 2.26,0.667 3.635,1.292 1.375,0.625 10 Rotational Direction of Printed Board 2.271,1.635 3.188,1.979 0.917,0.344 10 Pattern Width 0.958,2.729 1.74,3.073 0.781,0.344 10 Phase A: + 4.927,1.115 5.708,1.458 0.781,0.344 10 Phase A: + 0.979,3.5 1.76,3.844 0.781,0.344 10 Phase B: + 4.948,1.958 5.729,2.302 0.781,0.344 10 Phase B: + 4.438,2.927 5.385,3.271 0.948,0.344 10 Printed Board 4.042,2.5 6.427,2.844 2.385,0.344 10 Rotational Direction of Printed Board 3.51,2.135 4.813,2.479 1.302,0.344 10 Fixed Contact Point 4.448,3.385 5.229,3.729 0.781,0.344 10 Pattern 2.188,3.771 2.792,4.115 0.604,0.344 10 Phase A 2.188,4.125 2.792,4.469 0.604,0.344 10 Phase B 0.708,3.104 1.75,3.448 1.042,0.344 10 Common: GND 4.667,1.542 5.708,1.885 1.042,0.344 10 Common: GND 3.594,4.385 4.917,4.74 1.323,0.354 10 Pattern Width 2.81°



j.

Cooler Condenser Assembly

i.

A Global Inner-fin Condenser (GIC) is provided. This condenser has tubes with high-density inner fins, and outer fins which allows the adoption of thinner cores, contributing to the efficiency of cooling performance.

Y210636C02
5.125,0.865 5.333,0.563 5.333,0.563 5.5,0.563 true 5.865,2.052 6.073,1.75 6.073,1.75 6.24,1.75 true 4.552,3.177 4.719,3.177 4.719,3.177 4.927,2.813 true 5.594,0.479 5.906,0.635 0.313,0.156 10 false *1 6.302,1.667 6.521,1.865 0.219,0.198 10 false *2 4.344,3.104 4.552,3.302 0.208,0.198 10 false *3 4.208,2.417 4.521,2.573 0.313,0.156 10 false *a 4.354,1.375 4.51,1.542 0.156,0.167 10 false A 5.333,1.375 5.49,1.542 0.156,0.167 10 false A
*1 Inner Fin Tube *2 Outer Fin
*3 Fin Louver - -
*a A-A Cross Section - -



ii.

In the sub-cool cycle, after the refrigerant passes through the condensing portion of the cooler condenser assembly, both the liquid refrigerant and the gaseous refrigerant that could not be liquefied are cooled again in the super-cooling portion. Thus, the refrigerant is sent to the No. 1 cooler evaporator sub-assembly in an almost completely liquefied state.

Y210637C02
4.417,0.99 4.167,0.333 4.167,0.333 4,0.333 true 2.573,1.302 2.323,0.646 2.323,0.646 2.156,0.646 true 4.333,2.781 4,3.417 4,3.417 3.833,3.417 true 1.563,2.094 1.177,2.469 1.177,2.469 1.01,2.469 true 1.396,1.719 1.167,1.5 1.167,1.5 1,1.5 true 6.333,1.25 6.646,1.406 0.313,0.156 10 false *a 6.313,2.552 6.625,2.708 0.313,0.156 10 false *b 3.792,0.26 4.104,0.417 0.313,0.156 10 false *c 1.958,0.583 2.271,0.74 0.313,0.156 10 false *d 0.792,1.438 1.104,1.594 0.313,0.156 10 false *e 0.823,2.406 1.135,2.563 0.313,0.156 10 false *f 3.635,3.333 3.948,3.49 0.313,0.156 10 false *g
*a Gaseous Refrigerant *b Liquid Refrigerant
*c Condensing Portion *d Modulator
*e Cooler Dryer *f Filter
*g Super-cooling Portion - -




k.

Compressor with Pulley Assembly

i.

The compressor with pulley assembly is a continuously variable capacity type with a capacity that varies in accordance with the cooling load of the air conditioning.


ii.

The compressor with pulley assembly consists of the shaft, lug plate, piston, shoe, crank chamber, cylinder and solenoid control valve.

Y111821E04
3.375,1.417 2.854,0.406 2.854,0.406 2.656,0.406 true 2.917,1.313 2.208,0.604 2.208,0.604 2.021,0.604 true 2.365,1.958 1.542,1.25 1.542,1.25 1.344,1.25 true 3.156,2.479 2.635,3.313 2.635,3.313 2.438,3.313 true 3.396,2.656 3.073,3.51 3.073,3.51 2.875,3.51 true 3.99,2.656 4.51,3.49 4.51,3.49 4.708,3.49 true 4.74,2.698 5.26,3.458 5.26,3.458 5.458,3.458 true 4.083,1.302 4.604,0.469 4.604,0.469 4.802,0.469 true 2.5,0.323 2.74,0.625 0.24,0.302 10 false *1 1.813,0.521 2.052,0.823 0.24,0.302 10 false *2 1.167,1.167 1.406,1.469 0.24,0.302 10 false *3 2.26,3.219 2.5,3.521 0.24,0.302 10 false *4 2.698,3.427 2.938,3.729 0.24,0.302 10 false *5 4.844,0.406 5.083,0.708 0.24,0.302 10 false *5 4.76,3.438 5,3.74 0.24,0.302 10 false *6 5.5,3.375 5.74,3.677 0.24,0.302 10 false *7

Text in Illustration
*1 Shoe *2 Crank Chamber
*3 Shaft *4 Lug Plate
*5 Piston *6 Cylinder
*7 Solenoid Control Valve - -


iii.

A variable suction side throttle is used.

·

Refrigerant inlet pressure is applied to the top of the variable suction side throttle and crank chamber pressure to the bottom of the variable suction side throttle.

·

The pressure difference moves the variable suction side throttle up and down, expanding and contracting the refrigerant inlet passage.

·

When the refrigerant flow is at a maximum, the refrigerant inlet pressure is greater than the crank chamber pressure. This causes the variable suction side throttle to move down, fully opening the refrigerant inlet passage and lowering the refrigerant inlet resistance.

·

When the amount of refrigerant flow is controlled, the crank chamber pressure is greater than the refrigerant inlet pressure, raising the variable inlet throttle to contract the flow passage.

·

These controls suppress noise by reducing pulsation from the refrigerant inlet.


Y111822E06
1.917,1.573 1.729,1.104 1.729,1.104 1.458,1.104 true 2.156,1.677 2.344,1.094 2.344,1.094 2.615,1.094 true 2.344,2.302 2.667,2.521 2.667,2.521 2.813,2.521 true 5.01,1.542 4.823,1.073 4.823,1.073 4.552,1.073 true 5.177,1.76 5.406,1.063 5.406,1.063 5.667,1.063 true 5.458,2.083 5.792,2.302 5.792,2.302 5.927,2.302 true 5.406,2.896 5.74,3.313 5.74,3.313 5.885,3.313 true 3.656,6.146 3.823,6.594 3.823,6.594 3.969,6.594 true 3.969,0.917 4.25,1.177 0.281,0.26 12 false *B 0.792,0.906 1.073,1.167 0.281,0.26 12 false *A 1.271,1.021 1.469,1.281 0.198,0.26 10 false *1 1.052,1.99 1.333,2.25 0.281,0.26 10 false *2 4.25,1.969 4.531,2.229 0.281,0.26 10 false *2 4.365,0.99 4.573,1.25 0.208,0.26 10 false *1 5.708,0.979 5.99,1.24 0.281,0.26 10 false *b 2.656,1.021 2.938,1.281 0.281,0.26 10 false *a 2.844,2.448 3.125,2.708 0.281,0.26 10 false *3 5.948,3.24 6.229,3.5 0.281,0.26 10 false *4 5.948,2.229 6.229,2.49 0.281,0.26 10 false *3 4,6.542 4.281,6.802 0.281,0.26 10 false *5

Text in Illustration
*A Maximum Volume of Refrigerant *B Controlled Volume of Refrigerant
*1 Refrigerant Passage A *2 Inlet Chamber
*3 Variable Suction Side Throttle *4 Crank Pressure Inlet Chamber
*5 Compressor with Pulley Assembly - -
*a High Flow *b Low Flow
V100135

Crank Chamber Pressure
V100136

Refrigerant Flow


iv.

A Damper Limiter (DL) type air conditioning pulley is used. A cylinder-type damper is used for this compressor with pulley assembly and the torque fluctuations have been suppressed, thus making the inertia weight unnecessary. As a result, the weight of the compressor with pulley assembly has been reduced.

Y111823E04
5.438,2.156 5.917,2.719 5.917,2.719 6.063,2.719 true 1.646,2.385 2.156,2.948 2.156,2.948 2.302,2.948 true 6.073,1.167 5.74,0.75 5.74,0.75 5.594,0.75 true 2.719,1.344 2.385,0.927 2.385,0.927 2.24,0.927 true 0.271,0.458 0.563,0.719 0.292,0.26 12 false *A: 3.781,0.427 4.073,0.688 0.292,0.26 12 false *B: 6.104,2.625 6.385,2.885 0.281,0.26 10 false *1 2.344,2.865 2.625,3.125 0.281,0.26 10 false *1 5.406,0.656 5.594,0.917 0.188,0.26 10 false *2 2.073,0.865 2.25,1.125 0.177,0.26 10 false *1

Text in Illustration
*A 5TSE10C Compressor *B Conventional Type Compressor
*1 Damper *2 Inertia Weight



l.

Clean Air Filter

i.

A high efficiency type clean air filter is used to remove dust and other micron particles from air entering from outside the vehicle to provide a comfortable cabin of clean air. The clean air filter is installed in the upper section of the blower with fan motor assembly.

Y183265E02
2.031,1.979 2.125,1.979 2.125,1.979 2.906,1.563 true 2.833,2.448 2.938,2.448 2.938,2.448 3.708,2.031 true 5.083,2.49 4.979,2.49 4.979,2.49 4.521,2.188 true 1.844,1.896 2.073,2.063 0.229,0.167 10 false *1 2.667,2.344 2.896,2.51 0.229,0.167 10 false *2 5.125,2.406 5.354,2.573 0.229,0.167 10 false *3

Text in Illustration
*1 Blower with Fan Motor Assembly *2 Clean Air Filter
*3 Air Filter Case - -



m.

Thermistor Assembly

i.

The thermistor assembly detects the ambient temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.



n.

Cooler (Room Temperature Sensor) Thermistor

i.

The cooler (room temperature sensor) thermistor detects the room temperature based on changes in the resistance of its built-in thermistor. This signal is used by the air conditioning amplifier assembly.



o.

Automatic Light Control Sensor

i.

The automatic light control sensor detects (in the form of changes in the current that flows through the built-in photo diode) the changes in the amount of sunlight and outputs these sunlight strength signals to the air conditioning amplifier assembly.




OPERATION


a.

Mode Position and Door Operation

Y111173E05
0.802,3.854 0.469,3.854 0.469,3.854 0.469,4.375 true 2.615,3.792 2.281,3.792 2.281,3.792 2.281,4.313 false 5.469,2.219 5.469,1.938 5.469,1.938 5.604,1.938 true 5.469,4.99 5.469,5.281 5.469,5.281 5.625,5.281 true 3.656,3.292 3.656,1.615 3.656,1.615 3.375,1.615 true 1.74,2.458 2.354,2.75 0.615,0.292 10 false RECIRC 0.156,2.417 0.771,2.708 0.615,0.292 10 false FRESH 0.063,4.375 1.521,4.74 1.458,0.365 10 false Blower with Fan Motor Sub-assembly 1.813,4.375 3.365,4.719 1.552,0.344 10 false No. 1 Cooler Evaporator Sub-assembly 3.677,0.094 5.365,0.292 1.688,0.198 10 false Front Defroster Assembly 5.771,0.667 6.698,1.417 0.927,0.75 10 false Side Defroster Nozzle RH 2.052,1.542 3.323,2.302 1.271,0.76 10 false Heater Radiator Unit Sub-assembly 1.594,0.677 3.167,1.24 1.573,0.563 10 false Side Defroster Nozzle LH 5.688,1.865 6.646,2.25 0.958,0.385 10 false Front Footwell Register RH 5.656,5.208 6.615,5.573 0.958,0.365 10 false Front Footwell Register LH 3.927,6.25 4.75,6.844 0.823,0.594 10 false Front Center Register 2.625,6.24 3.406,6.844 0.781,0.604 10 false Front Side Register LH 4.958,6.219 5.76,6.844 0.802,0.625 10 false Front Side Register RH

HINT:

This illustration is a model diagram showing the doors positions in each mode. The parts layout and the number of the doors in the illustration are different from those of the actual system.


Control Damper Operation Position Damper Position Operation
Air Inlet FRESH A Brings in fresh air.
RECIRCULATION B Recirculates internal air.
Air Mix MAX COLD to MAX HOT C to D Varies the mixture ratio of the fresh air and the recirculation air in order to regulate the temperature continuously from HOT to COLD.
Mode
Y130484

FACE E, J Air blows out of the center register and side register.
Y130485

BI-LEVEL F, J Air blows out of the center register, side registers and front footwell register ducts.
Y130486

FOOT F, I Air blows out of the front footwell register ducts and side register. In addition, air blows out slightly from the front defroster and side defroster.
Y130487

FOOT/DEF F, H Defrosts the windshield through the center defroster, side defroster and side register, while air is also blown out from the front footwell register ducts.
Y130488

DEF E, G Defrosts the windshield through the center defroster, side defroster and side register.


b.

Air Outlets and Airflow Volume

Y183266E02
4.135,1.542 4.344,1.792 0.208,0.25 10 false A 4.5,1.438 4.708,1.688 0.208,0.25 10 true A 2.76,2.302 2.969,2.552 0.208,0.25 10 false B 5.802,1.479 6.01,1.729 0.208,0.25 10 false B 3.031,3.156 3.24,3.406 0.208,0.25 10 false C 4.552,2.792 4.76,3.042 0.208,0.25 10 false C 2.083,1.5 2.292,1.698 0.208,0.198 10 true D 3.104,0.417 3.375,0.625 0.271,0.208 10 false D 5.802,0.719 6.01,0.969 0.208,0.25 10 false D

Indication Mode A B C D
Center Side Foot Defroster
Y130484

FACE
Y197899

Y197899

- -
Y130485

BI-LEVEL
Y197898

Y197898

Y197899

-
Y130486

FOOT -
Y197897

Y197899

Y197897

Y130487

FOOT/DEF -
Y197897

Y197898

Y197898

Y130488

DEF -
Y197898

-
Y197899


HINT:

The size of the circle ○ indicates the proportion of airflow volume.



c.

Side Register

i.

The side register has been adopted which allows the user to change the airflow modes and airflow direction/amount at will by operating a dial.


ii.

Moving the dial at the center of the side register operates the vanes inside the side register. In this way, the airflow area can be adjusted at will by the user, enabling increased comfort.


iii.

Airflow direction can be adjusted by moving the dial at the center of the side register up, down, left, or right.

Y183269E01
2.579,0.476 2.812,0.649 0.233,0.172 10 *1 2.529,0.548 2.374,0.548 2.374,0.548 1.979,1.224 false 4.494,0.347 4.720,0.565 0.226,0.218 10 *a 3.483,1.52 3.716,1.693 0.233,0.172 10 *2 3.669,1.589 3.855,1.589 3.855,1.589 4.166,1.136 false 1.096,2.827 1.284,3.015 0.188,0.188 10 *b 1.096,4.282 1.284,4.471 0.188,0.188 10 *c 5.824,2.918 6.012,3.107 0.188,0.188 10 *e 5.824,4.325 6.012,4.513 0.188,0.188 10 *f 1.096,5.599 1.284,5.788 0.188,0.188 10 *d

Text in Illustration
*1 Side Register *2 Dial
*a 60° *b Spot Airflow
*c Wide Airflow *d Shut
*e Image of the air volume (Spot Airflow) *f Image of the air volume (Wide Airflow)
V100135

By rotating the center dial, the airflow area can be adjusted.
V100136

By moving the dial up, down, left or right, the direction of airflow can be adjusted.



d.

Compressor Operation

i.

The crank chamber is connected to the suction passage. A solenoid control valve is provided between the suction passage (low pressure) and the discharge passage (high pressure).


ii.

The solenoid control valve operates under duty cycle control in accordance with the signals from the air conditioning amplifier assembly.

Y108998E08
1.615,0.323 2.771,0.323 2.771,0.323 3.167,1.167 true 4.198,2.375 4.438,2.375 4.438,2.375 4.573,2.25 true 1.615,1.344 2.24,1.344 2.24,1.344 2.458,1.708 true 1.427,0.24 1.698,0.469 0.271,0.229 10 false *1 1.427,1.25 1.698,1.479 0.271,0.229 10 false *2 4.031,2.281 4.302,2.51 0.271,0.229 10 false *4 4.927,2.917 5.198,3.146 0.271,0.229 10 false *5 4.927,0.375 5.198,0.604 0.271,0.229 10 false *6 3.604,1.74 3.875,1.969 0.271,0.229 10 false *3 3.229,3.219 3.5,3.448 0.271,0.229 10 false *3

Text in Illustration
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly


iii.

When the solenoid control valve closes (the solenoid coil is energized), a difference in pressure is created and the pressure in the crank chamber decreases. Then, the pressure applied to the right side of the piston becomes greater than the pressure applied to the left side of the piston. This compresses the spring and tilts the lug plate. As a result, the piston stroke increases and the discharge capacity increases.

Y108999E08
1.615,0.167 2.771,0.167 2.771,0.167 3.167,1.01 true 4.198,2.24 4.438,2.24 4.438,2.24 4.573,2.104 true 1.615,1.198 2.24,1.198 2.24,1.198 2.458,1.552 true 1.427,0.094 1.698,0.323 0.271,0.229 10 false *1 1.813,2.51 2.083,2.74 0.271,0.229 10 false *a 3.781,3.573 4.052,3.802 0.271,0.229 10 false *b 1.427,1.094 1.698,1.323 0.271,0.229 10 false *2 4.01,2.156 4.281,2.385 0.271,0.229 10 false *4 4.927,2.75 5.198,2.979 0.271,0.229 10 false *5 4.927,0.198 5.198,0.427 0.271,0.229 10 false *6 3.625,1.594 3.896,1.823 0.271,0.229 10 false *3 3.229,3.052 3.5,3.281 0.271,0.229 10 false *3

Text in Illustration
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Large


iv.

When the solenoid control valve opens (the solenoid coil is not energized), the difference in pressure disappears. Then, the pressure applied to the left side of the piston becomes the same as the pressure applied to the right side of the piston. Thus, the spring elongates and eliminates the tilt of the lug plate. As a result, there is a small piston stroke and the discharge capacity decreases.

Y109000E08
1.615,0.156 2.771,0.156 2.771,0.156 3.167,1 true 4.198,2.219 4.438,2.219 4.438,2.219 4.573,2.083 true 1.615,1.156 2.24,1.156 2.24,1.156 2.458,1.51 true 1.427,0.073 1.698,0.302 0.271,0.229 10 false *1 1.813,2.531 2.083,2.76 0.271,0.229 10 false *a 3.948,3.573 4.219,3.802 0.271,0.229 10 false *b 1.427,1.073 1.698,1.302 0.271,0.229 10 false *2 4.021,2.135 4.292,2.365 0.271,0.229 10 false *4 4.927,2.74 5.198,2.969 0.271,0.229 10 false *5 4.927,0.198 5.198,0.427 0.271,0.229 10 false *6 3.625,1.594 3.896,1.823 0.271,0.229 10 false *3 3.594,3.063 3.865,3.292 0.271,0.229 10 false *3

Text in Illustration
*1 Suction Passage *2 Crank Chamber
*3 Piston *4 Discharge Passage
*5 Solenoid Control Valve *6 Air Conditioning Amplifier Assembly
*a Crank Chamber Pressure + Spring Force *b Piston Stroke: Small




DIAGNOSIS


a.

The air conditioning amplifier assembly has a self-diagnosis function. It stores any operation failures in the air conditioning system memory in the form of DTCs. For details, refer to the Repair Manual.