Home › General › SPECIFICATIONS › HEATING / AIR CONDITIONING
RM19S0E _V1 General _051446 SPECIFICATIONS _0248022 HEATING / AIR CONDITIONING F

SPECIFICATIONS  HEATING / AIR CONDITIONING  SERVICE DATA  


Refrigerant charge volume (w/o Fan shroud ventilation duct) 330 to 390 g (11.6 to 13.8 oz.)
Refrigerant charge volume (w/ Fan shroud ventilation duct) 350 to 410 g (12.3 to 14.5 oz.)
HEATER BLOWER MOTOR RELAY ASSEMBLY 3 - 4: Below 1 Ω (Battery voltage not applied)
3 - 4: 10 kΩ or higher (Battery voltage applied to terminals 1 and 2)
3 - 5: 10 kΩ or higher (Battery voltage not applied)
3 - 5: Below 1 Ω (Battery voltage applied to terminals 1 and 2)

for Manual Transaxle
Idling speed
Switch A/C off
600 to 700 rpm
Idling speed
Switch A/C on (A/C Lo → Hi)
700 → 900 rpm

for Automatic Transaxle
Idling speed
Switch A/C off
650 to 750 rpm
Idling speed
Switch A/C on (A/C Lo → Hi)
700 → 900 rpm