Home › Engine / Hybrid System › 1NZ-FE FUEL › FUEL PUMP
RM19S0E _51 Engine / Hybrid System _051453 1NZ-FE FUEL _0248098 FUEL PUMP G

1NZ-FE FUEL  FUEL PUMP  INSPECTION  


PROCEDURE

Hide 23221 1.INSPECT FUEL PUMP

a.
A171358E02
1.3,0.153 1.412,0.318 0.112,0.165 10 1 1.637,0.593 1.441,0.241 false 2.086,0.153 2.198,0.318 0.112,0.165 10 2 1.856,0.593 2.052,0.241 false 0.166,0.162 0.337,0.327 0.171,0.165 10 *a

Check the resistance.

i.

Measure the resistance according to the value(s) in the table below.

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 0.2 to 3.0 Ω


Text in Illustration
*a Component without harness connected
(Fuel Pump)

If the result is not as specified, replace the fuel pump.



b.

Check fuel pump operation.

i.

Connect the positive (+) lead of the battery to terminal 1 of the connector and the negative (-) lead to terminal 2. Check that the fuel pump operates.

NOTICE:
·

This test must be done quickly (within 10 seconds) to prevent the coil from burning out.

·

Keep the fuel pump as far away from the battery as possible.

·

Always switch the voltage on and off at the battery, not the fuel pump.