25860
1.INSTALL NO. 1 VACUUM SWITCHING VALVE ASSEMBLY
Insert the No. 1 vacuum switching valve assembly into the No. 1 air cleaner hose to install it.
Engage the clamp to connect the wire harness to the No. 1 vacuum switching valve assembly.
Connect the purge No. 1 vacuum switching valve assembly connector.
Connect the No. 2 fuel vapor feed hose to the No. 1 vacuum switching valve assembly.
Connect the fuel vapor feed hose assembly to the No. 1 vacuum switching valve assembly and slide the hose clip to secure it.