Home › Drivetrain › U340E (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY
RM19S0E _52 Drivetrain _051465 U340E AUTOMATIC TRANSMISSION / TRANSAXLE _0248160 VALVE BODY ASSEMBLY G

U340E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 35240 1.INSPECT SHIFT SOLENOID VALVE S1

C155174E06
0.105,0.086 0.292,0.232 0.188,0.147 10 *a

a.

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve S1)

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (S1) - Solenoid Body (S1) 20°C (68°F) 11 to 15 Ω


If the value is not as specified, replace the shift solenoid valve S1.


b.

Connect the positive (+) battery lead to the terminal of the solenoid connector, and the negative (-) battery lead to the solenoid body, and check the operation of the shift solenoid valve.

NOTICE:

While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.


OK:

The solenoid makes an operating sound.


If the operation cannot be done as specified, replace the shift solenoid valve S1.


Hide 35230 2.INSPECT SHIFT SOLENOID VALVE S2

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 35250A 3.INSPECT SHIFT SOLENOID VALVE ST

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 35270A 4.INSPECT SHIFT SOLENOID VALVE SL

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 35290A 5.INSPECT SHIFT SOLENOID VALVE SLT

C155176E20
1.479,1.177 1,0.854 false 1.688,1.188 2.146,0.854 false 1.479,3.188 1,2.875 false 1.688,3.188 2.146,2.875 false 0.146,0.042 0.417,0.188 0.271,0.146 10 false *a 1.302,3.604 1.5,3.802 0.198,0.198 10 false (-) 2.01,3.604 2.208,3.802 0.198,0.198 10 false (+) 0.844,0.76 0.979,0.927 0.135,0.167 10 false 1 2.229,0.771 2.365,0.938 0.135,0.167 10 false 2 0.844,2.771 0.979,2.938 0.135,0.167 10 false 1 2.208,2.76 2.344,2.927 0.135,0.167 10 false 2

a.

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SLT)

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.0 to 5.6 Ω


If the value is not as specified, replace the shift solenoid valve SLT.


b.

Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the shift solenoid valve.

NOTICE:

While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.


OK:

The solenoid makes an operating sound.


If the operation cannot be done as specified, replace the shift solenoid valve SLT.