Home › Drivetrain › U441E (AUTOMATIC TRANSMISSION / TRANSAXLE) › VALVE BODY ASSEMBLY
RM19S0E _52 Drivetrain _051466 U441E AUTOMATIC TRANSMISSION / TRANSAXLE _0248175 VALVE BODY ASSEMBLY G

U441E AUTOMATIC TRANSMISSION / TRANSAXLE  VALVE BODY ASSEMBLY  INSPECTION  


PROCEDURE

Hide 1.INSPECT SHIFT SOLENOID VALVE S1

a.
C117936E13
0.708,2.823 0.865,3.031 0.156,0.208 10 false (-) 0.094,0.031 1.615,0.198 1.521,0.167 10 false *a 1.281,2.833 1.5,3.031 0.219,0.198 10 false (+)

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve S1)

Standard Resistance:
Tester Connection Condition Specified Condition
Solenoid Connector (S1) - Solenoid Body (S1) 20°C (68°F) 11 to 15 Ω


If the value is not as specified, replace the shift solenoid valve S1.



b.

Connect the positive (+) battery lead to the terminal of the solenoid connector, and the negative (-) battery lead to the solenoid body, and check the operation of the shift solenoid valve.

NOTICE:

While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.


OK:

The solenoid makes an operating sound.


If the operation cannot be done as specified, replace the shift solenoid valve S1.



Hide 2.INSPECT SHIFT SOLENOID VALVE S2

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 3.INSPECT SHIFT SOLENOID VALVE ST

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 4.INSPECT SHIFT SOLENOID VALVE SL

HINT:

Refer to Inspect Shift Solenoid Valve S1.


Hide 5.INSPECT SHIFT SOLENOID VALVE SLT

a.
C355417E01
1.51,1.135 1,0.781 false 2.25,0.823 1.813,1.125 false 1.5,3.229 0.99,2.875 false 2.25,2.938 1.802,3.24 false 0.177,0.146 0.365,0.344 0.188,0.198 10 false *a 0.844,0.656 0.99,0.865 0.146,0.208 10 false 1 2.281,2.823 2.469,3.021 0.188,0.198 10 false 2 2.292,0.708 2.479,0.906 0.188,0.198 10 false 2 0.854,2.792 1,3 0.146,0.208 10 false 1 1.24,4.24 1.406,4.448 0.167,0.208 10 false (-) 1.948,4.229 2.156,4.438 0.208,0.208 10 false (+)

Measure the resistance according to the value(s) in the table below.

Text in Illustration
*a Component without harness connected
(Shift Solenoid Valve SLT)

Standard Resistance:
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 5.1 to 5.5 Ω


If the value is not as specified, replace the shift solenoid valve SLT.



b.

Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the shift solenoid valve.

NOTICE:

While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.


OK:

The solenoid makes an operating sound.


If the operation cannot be done as specified, replace the shift solenoid valve SLT.